Serum human chorionic gonadotropin measurement in the diagnosis of ectopic pregnancy when transvaginal sonography is inconclusive

被引:86
作者
Mol, BWJ
Hajenius, PJ
Engelsbel, S
Ankum, WM
Van der Veen, F
Hemrika, DJ
Bossuyt, PMM
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1100 DE Amsterdam, Netherlands
[2] Univ Amsterdam, Dept Obstet & Gynecol, NL-1100 DE Amsterdam, Netherlands
[3] Univ Amsterdam, Ctr Reprod Med, NL-1100 DE Amsterdam, Netherlands
[4] Onze Lieve Vrouwe Gasthuis, Dept Obstet & Gynecol, Amsterdam, Netherlands
关键词
diagnosis; ectopic pregnancy; serum human chorionic gonadotropin transvaginal sonography;
D O I
10.1016/S0015-0282(98)00278-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess the accuracy of initial and repeated serum hCG measurements in the diagnosis of ectopic pregnancy (EP) in patients in whom transvaginal sonography is inconclusive and to evaluate whether patient characteristics influence the accuracy of serum hCG measurements. Design: Prospective study. Setting: Two large teaching hospitals in Amsterdam, the Netherlands. Patient(s): Three hundred fifty-four consecutively seen pregnant patients with suspected EP and inconclusive transvaginal sonographic findings. Intervention(s): Serum hCG measurements. Main Outcome Measure(s): The performance of repeated serum hCG measurements in the diagnosis of EP was evaluated through the analysis of receiver operating characteristic curves. Result(s): Initial serum hCG measurements were more diagnostic in conjunction with sonographic evidence of an ectopic mass or fluid in the pouch of Douglas than in the absence of sonographic abnormalities. On repeated measurement, the course of the serum hCG concentration provided more diagnostic information than did the absolute serum hCG concentration 2 and 4 days after the start of the diagnostic process. Conclusion(s): The interpretation of serum hCG measurements should depend on additional findings at tr;transvaginal sonography. A cutoff level of 1,500 IU/L is recommended for patients with an ectopic mass or fluid in thr pouch of Douglas; in patients without these findings, the cutoff level should be at least 2,000 IU/L. Four days after the start of the diagnostic process, any rise in the serum hCG concentration makes the diagnosis of EP very likely. (Fertil Steril(R) 1998;70:972-81. (C) 1998 by American Society for Reproductive Medicine.).
引用
收藏
页码:972 / 981
页数:10
相关论文
共 50 条
[21]   The relationship between serum levels of epidermal growth factor and β-human chorionic gonadotropin and the type and prognosis of ectopic pregnancy [J].
Geng, Dandan ;
Liu, Manfang ;
Wu, Dongyan ;
Yue, Benming .
ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2024, 310 (02) :1179-1187
[22]   Human chorionic gonadotropin patterns after a single dose of methotrexate for ectopic pregnancy [J].
Natale, A ;
Busacca, M ;
Candiani, M ;
Gruft, L ;
Izzo, S ;
Felicetta, I ;
Vignali, M .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2002, 100 (02) :227-230
[23]   TRANSVAGINAL DOPPLER SONOGRAPHY FOR DETECTING ECTOPIC PREGNANCY - IS IT REALLY NECESSARY [J].
ACHIRON, R ;
GOLDENBERG, M ;
LIPITZ, S ;
MASHIACH, S ;
OELSNER, G .
ISRAEL JOURNAL OF MEDICAL SCIENCES, 1994, 30 (11) :820-825
[24]   Methotrexate-treated ectopic pregnancy: beta human chorionic gonadotropin serum changes as a success predictor using a mathematical model validation [J].
Kovaleva, Aleksandra ;
Irishina, Natalia ;
Pereira, Augusto ;
Cuesta-Guardiola, Tatiana ;
Ortiz-Quintana, Luis .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2017, 210 :35-38
[25]   HUMAN CORPUS-LUTEUM - HUMAN CHORIONIC-GONADOTROPIN RECEPTORS DURING ECTOPIC PREGNANCY [J].
DAWOOD, MY ;
KHANDAWOOD, FS .
FERTILITY AND STERILITY, 1994, 62 (04) :711-715
[26]   IMPROVED SENSITIVITY AND SPECIFICITY OF A SINGLE MEASUREMENT OF SERUM PROGESTERONE OVER SERIAL QUANTITATIVE BETA-HUMAN CHORIONIC-GONADOTROPIN IN SCREENING FOR ECTOPIC PREGNANCY [J].
STOVALL, TG ;
LING, FW ;
ANDERSEN, RN ;
BUSTER, JE .
HUMAN REPRODUCTION, 1992, 7 (05) :723-725
[27]   Determination of Human Chorionic Gonadotropin in Postmortem Samples in Ectopic Pregnancies [J].
Palmiere, Cristian ;
Lesta, Maria del Mar ;
Fanton, Laurent ;
Ventura, Francesco ;
Bonsignore, Alessandro ;
Bonetti, Luca Reggiani .
JOURNAL OF FORENSIC SCIENCES, 2016, 61 (01) :234-237
[28]   Differentiating tubal abortion from viable ectopic pregnancy with serum CA-125 and β-human chorionic gonadotropin determinations [J].
Predanic, M .
FERTILITY AND STERILITY, 2000, 73 (03) :522-525
[29]   Differences in Serum Human Chorionic Gonadotropin Rise in Early Pregnancy by Race and Value at Presentation [J].
Barnhart, Kurt T. ;
Guo, Wensheng ;
Cary, Mark S. ;
Morse, Christopher B. ;
Chung, Karine ;
Takacs, Peter ;
Senapati, Suneeta ;
Sammel, Mary D. .
OBSTETRICS AND GYNECOLOGY, 2016, 128 (03) :504-511
[30]   CRITERIA FOR TRANSVAGINAL SONOGRAPHIC DIAGNOSIS OF ECTOPIC PREGNANCY [J].
ROTTEM, S ;
THALER, I ;
LEVRON, J ;
PERETZ, BA ;
ITSKOVITZ, J ;
BRANDES, JM .
JOURNAL OF CLINICAL ULTRASOUND, 1990, 18 (04) :274-279