Serum human chorionic gonadotropin measurement in the diagnosis of ectopic pregnancy when transvaginal sonography is inconclusive

被引:83
作者
Mol, BWJ
Hajenius, PJ
Engelsbel, S
Ankum, WM
Van der Veen, F
Hemrika, DJ
Bossuyt, PMM
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1100 DE Amsterdam, Netherlands
[2] Univ Amsterdam, Dept Obstet & Gynecol, NL-1100 DE Amsterdam, Netherlands
[3] Univ Amsterdam, Ctr Reprod Med, NL-1100 DE Amsterdam, Netherlands
[4] Onze Lieve Vrouwe Gasthuis, Dept Obstet & Gynecol, Amsterdam, Netherlands
关键词
diagnosis; ectopic pregnancy; serum human chorionic gonadotropin transvaginal sonography;
D O I
10.1016/S0015-0282(98)00278-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess the accuracy of initial and repeated serum hCG measurements in the diagnosis of ectopic pregnancy (EP) in patients in whom transvaginal sonography is inconclusive and to evaluate whether patient characteristics influence the accuracy of serum hCG measurements. Design: Prospective study. Setting: Two large teaching hospitals in Amsterdam, the Netherlands. Patient(s): Three hundred fifty-four consecutively seen pregnant patients with suspected EP and inconclusive transvaginal sonographic findings. Intervention(s): Serum hCG measurements. Main Outcome Measure(s): The performance of repeated serum hCG measurements in the diagnosis of EP was evaluated through the analysis of receiver operating characteristic curves. Result(s): Initial serum hCG measurements were more diagnostic in conjunction with sonographic evidence of an ectopic mass or fluid in the pouch of Douglas than in the absence of sonographic abnormalities. On repeated measurement, the course of the serum hCG concentration provided more diagnostic information than did the absolute serum hCG concentration 2 and 4 days after the start of the diagnostic process. Conclusion(s): The interpretation of serum hCG measurements should depend on additional findings at tr;transvaginal sonography. A cutoff level of 1,500 IU/L is recommended for patients with an ectopic mass or fluid in thr pouch of Douglas; in patients without these findings, the cutoff level should be at least 2,000 IU/L. Four days after the start of the diagnostic process, any rise in the serum hCG concentration makes the diagnosis of EP very likely. (Fertil Steril(R) 1998;70:972-81. (C) 1998 by American Society for Reproductive Medicine.).
引用
收藏
页码:972 / 981
页数:10
相关论文
共 50 条
  • [1] Ectopic pregnancy with negative serum human chorionic gonadotropin
    Tang-Pedersen, Mikael
    Andersen, Bent
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2007, 86 (01) : 108 - 110
  • [2] TRANSVAGINAL SONOGRAPHY AND HUMAN CHORIONIC-GONADOTROPIN MEASUREMENTS IN SUSPECTED ECTOPIC PREGNANCY - A DETAILED ANALYSIS OF A DIAGNOSTIC-APPROACH
    ANKUM, WM
    VANDERVEEN, F
    HAMERLYNCK, JVTH
    LAMMES, FB
    HUMAN REPRODUCTION, 1993, 8 (08) : 1307 - 1311
  • [3] Comparison of Transabdominal and Transvaginal Sonography in the Diagnosis of Ectopic Pregnancy
    Malik, Safdar Ali
    Malik, Shumaila
    Maqbool, Ayesha
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2010, 4 (01): : 22 - 27
  • [4] Human chorionic gonadotropin ratio of hemoperitoneum versus venous serum improves early diagnosis of ectopic pregnancy
    Wang, YuDong
    Zhao, Hong
    Teng, YinCheng
    Lu, LiHua
    Tong, JianQian
    FERTILITY AND STERILITY, 2010, 93 (03) : 702 - 705
  • [5] Are gestational age and endometrial thickness alternatives for serum human chorionic gonadotropin as criteria for the diagnosis of ectopic pregnancy?
    Mol, BWJ
    Hajenius, PJ
    Engelsbel, S
    Ankum, WM
    van der Veen, F
    Hemrika, DJ
    Bossuyt, PMM
    FERTILITY AND STERILITY, 1999, 72 (04) : 643 - 645
  • [6] Longitudinal observations of human chorionic gonadotropin in serum following surgery for ectopic pregnancy
    Rempen, A
    Haubitz, I
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 1996, 258 (04) : 181 - 192
  • [7] TRANSVAGINAL SONOGRAPHY IN THE MANAGEMENT OF ECTOPIC PREGNANCY
    SADEK, AL
    SCHIOTZ, HA
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1995, 74 (04) : 293 - 296
  • [8] Relevance of declines in serum human chorionic gonadotropin levels to the management of persistent ectopic pregnancy
    Abe, Takashi
    Akira, Shigeo
    Negishi, Yasuyuki
    Ichikawa, Masao
    Nakai, Akihito
    Takeshita, Toshiyuki
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2009, 35 (05) : 961 - 966
  • [9] SERUM HUMAN CHORIONIC-GONADOTROPIN DYNAMICS DURING SPONTANEOUS RESOLUTION OF ECTOPIC PREGNANCY
    KORHONEN, J
    STENMAN, UH
    YLOSTALO, P
    FERTILITY AND STERILITY, 1994, 61 (04) : 632 - 636
  • [10] Application of redefined human chorionic gonadotropin curves for the diagnosis of women at risk for ectopic pregnancy
    Seeber, Beata E.
    Sammel, Mary D.
    Guo, Wensheng
    Zhou, Lan
    Hummel, Amy
    Barnhart, Kurt T.