Stray magnetic field distributed around a PMSM

被引:11
作者
Adam, Ali Ahmed [1 ]
Gulez, Kayhan [2 ]
Koroglu, Selim [3 ]
机构
[1] Fatih Univ, Fac Engn, Dept Elect Elect Engn, Istanbul, Turkey
[2] Yildiz Tech Univ, Elect Elect Engn Fac, Dept Control & Automat Engn, Istanbul, Turkey
[3] Yildiz Tech Univ, Elect Elect Engn Fac, Dept Elect Engn, Istanbul, Turkey
关键词
Magnetic field measurement; permanent magnet synchronous motor; stray electromagnetic field; magnetic exposure; rotor position; ELECTROMAGNETIC-FIELDS; CHILDHOOD LEUKEMIA; POOLED ANALYSIS; PINEAL-GLAND; EXPOSURE;
D O I
10.3906/elk-1003-404
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this work, the low frequency electromagnetic emission from permanent magnet synchronous motors is studied. The main objective is to provide a safety region for humans in the vicinity of these motors, especially as these motors are now being used widely in inhabited areas, where high flux densities are expected. In this study, a new proposed equivalent magnetic circuit is used to estimate the stray fields at the surface of the motor. The analysis showed that the emission of the stray field in the radial direction depends on the permeability of the stator body. Low values of permeability may result in very high stray flux emissions with levels that require shielding to protect people in the surrounding areas. Relatively far away from the stator (e.g. 50 cm for the tested motor), the flux is normally at a low level and should not pose a threat to life. The traced waveforms of the magnetic field showed that waveforms similar to the heartbeat may result, which constitutes a threat to people with pacemakers. In addition, the traced waveform of the x-sensor (radial component) provided important information that could be used to estimate the rotor position of the motor.
引用
收藏
页码:119 / 131
页数:13
相关论文
共 17 条
[1]  
Aasen SE, 1996, BIOL NEONATE, V70, P249
[2]   A pooled analysis of magnetic fields and childhood leukaemia [J].
Ahlbom, A ;
Day, N ;
Feychting, M ;
Roman, E ;
Skinner, J ;
Dockerty, J ;
Linet, M ;
McBride, M ;
Michaelis, J ;
Olsen, JH ;
Tynes, T ;
Verkasalo, PK .
BRITISH JOURNAL OF CANCER, 2000, 83 (05) :692-698
[3]  
*AM C GOV IND HYG, 1995, DOC THRESH LIM VAL P
[4]   Measurement of potential magnetic field interference with implanted cardioverter defibrillators or pacemakers [J].
Ashley, JR ;
Myers, B ;
Lilly, HC ;
Beatie, RE .
ELECTRO 98 - PROFESSIONAL PROGRAM PROCEEDINGS, 1998, :159-170
[5]   ELECTROMAGNETIC-FIELDS AND INFANT INCUBATORS [J].
BEARER, CF .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1994, 49 (05) :352-354
[6]   Electromagnetic emissions from electrical rotating machinery [J].
Ferrari, P ;
Mariscotti, A ;
Motta, A ;
Pozzobon, P .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2001, 16 (01) :68-73
[7]   A pooled analysis of magnetic fields, wire codes, and childhood leukemia [J].
Greenland, S ;
Sheppard, AR ;
Kaune, WT ;
Poole, C ;
Kelsh, MA .
EPIDEMIOLOGY, 2000, 11 (06) :624-634
[8]  
IARC, 2001, IARC MON EV CARC RIS
[9]  
*IEEE, 1991, 2911991 IEEE
[10]  
*IEEE, 1995, 6441994 IEEE