Nickel titanium T-loop wire dimensions for en masse retraction

被引:8
作者
Almeida, Layene [1 ]
Ribeiro, Alexandre
Martins, Renato Parsekian [1 ]
Viecilli, Rodrigo [2 ]
Martins, Lidia Parsekian [3 ]
机构
[1] Univ Estadual Paulista, Program Orthodont, Araraquara, Brazil
[2] Loma Linda Univ, Dept Orthodont, Loma Linda, CA 92350 USA
[3] Univ Estadual Paulista, Dept Orthodont, Araraquara, Brazil
关键词
T-loop; NiTi; Orthodontics; SPACE CLOSURE; FORCE CHARACTERISTICS; ORTHODONTIC LOOPS; CLINICAL-TRIAL; ALLOY; SYSTEMS; SPRINGS; MOMENT; ANCHORAGE;
D O I
10.2319/070515-449.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the force system produced by nickel-titanium T-loop springs made with wires of different dimensions. Material and Methods: Thirty compound T-loop springs were divided into three groups according to the dimensions of the nickel-titanium wire used for its design: 0.016" x 0.022", 0.017" x 0.025", and 0.018" x 0.025". The loops were tested on the Orthodontic Force Tester machine at an interbracket distance of 23 mm and activated 9 mm. The force in the y-axis and the moment in the x-axis were registered while the calculated moment to force ratio was recorded at each.5 mm of deactivation. The data were analyzed by three analyses of variance of repeated measures to detect differences and interactions between deactivation and wire size on force, moment, and moment-force ratios (M/F). Results: All groups had significantly different forces (P <.001). The 0.016" x 0.022" wire produced 1.78N of force while the 0.017" x 0.025" and the 0.018" x 0.025" produced 2.81 N and 3.25 N, respectively. The 0.016" x 0.022" wire produced lower moments (11.6 Nmm) than the 0.017" x 0.025" and 0.018" x 0.025" wires, which produced similar moments (13.9 Nmm and 14.4Nmm, respectively). The M/F produced was different for all groups; 0.016" x 0.022" T-loops produced 6.7 mm while the 0.017" x 0.025" and 0.018" x 0.025" T-loops produced 5.0 mm and 4.5 mm, respectively. An interaction was detected for all variables between deactivation and groups. Conclusion: The larger wires tested produced higher forces with slight increase on the moments, but the M/F produced by the 0.016" x 0.022" wire was the highest found.
引用
收藏
页码:810 / 817
页数:8
相关论文
共 25 条
  • [1] Superelastic nickel titanium alloy retraction springs - an experimental investigation of force systems
    Bourauel, C
    Drescher, D
    Ebling, J
    Broome, D
    Kanarachos, A
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 1997, 19 (05) : 491 - 500
  • [2] Burstone C., 1995, MODERN EDGEWISE MECH
  • [3] CHINESE NITI WIRE - A NEW ORTHODONTIC ALLOY
    BURSTONE, CJ
    BAI, Q
    MORTON, JY
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1985, 87 (06) : 445 - 452
  • [4] ON THE USE OF VERTICAL LOOPS IN RETRACTION SYSTEMS
    FAULKNER, MG
    LIPSETT, AW
    ELRAYES, K
    HABERSTOCK, DL
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1991, 99 (04) : 328 - 336
  • [5] A PARAMETRIC STUDY OF THE FORCE MOMENT SYSTEMS PRODUCED BY T-LOOP RETRACTION SPRINGS
    FAULKNER, MG
    FUCHSHUBER, P
    HABERSTOCK, D
    MIODUCHOWSKI, A
    [J]. JOURNAL OF BIOMECHANICS, 1989, 22 (6-7) : 637 - 647
  • [6] Felemban Nayef H, 2013, J Orthod Sci, V2, P28, DOI 10.4103/2278-0203.110330
  • [7] Force system evaluation of symmetrical beta-titanium T-loop springs preactivated by curvature and concentrated bends
    Fernandes Rabelo Caldas, Sergei Godeiro
    Martins, Renato Parsekian
    Galvao, Marilia Regalado
    Viana Vieira, Camilla Ivini
    Martins, Lidia Parsekian
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (02) : e53 - e58
  • [8] Effects of stress relaxation in beta-titanium orthodontic loops
    Fernandes Rabelo Caldas, Sergei Godeiro
    Martins, Renato Parsekian
    Viecilli, Rodrigo F.
    Galvao, Marilia Regalado
    Martins, Lidia Parsekian
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (02) : e85 - e92
  • [9] Garrec P, 2004, ANGLE ORTHOD, V74, P691
  • [10] En masse retraction and two-step retraction of maxillary anterior teeth in adult class I women - A comparison of anchorage loss
    Heo, Wook
    Nahm, Dong-Seok
    Baek, Seung-Hak
    [J]. ANGLE ORTHODONTIST, 2007, 77 (06) : 973 - 978