The Impact of Power Swing to the Operation of Distance Relay

被引:0
|
作者
Yusoff, Nooraizzat [1 ]
Abidin, Ahmad Farid [1 ]
Mahadan, Mohd Ezwan [1 ]
机构
[1] Univ Teknol MARA UiTM, Fac Elect Engn, Shah Alam 40450, Selangor, Malaysia
关键词
Power Swing; Distance Relay; Distributed Generation (DG) System; Apparent impedances; Zone Protection Z1 and Z2;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The presence of Distributed Generation (DG) System with the impact to the power swing during the instability was revealed. Some of the scenario which affect to the Zone Protection of Distance Relay has been observed. The result shows that the apparent impedance was passes through both the Zone 1 and Zone 2 of protection of distance relay during installing the DG system to the network. In this study, the distance relay is chosen to be a protective system into the system network in order to protect the transmission lines. The distance relay will have the instantaneous directional Zone 1 protection and one or more time delayed zones. The tripping signal produced by Zone 1 is instantaneous that is should not reach as far as the busbar at the end of the first line so it is to cover only 80-85% of the protected line of transmission lines. The remaining 15-20% provides a factor of safety in order to mitigate against errors introduced by the current and voltage transformer, and line impedance calculations. The 15-20% at the end of the line is protected by Zone 2. All of the circumstances during protective of transmission line with and without DG system have been captured and discussed in the end of this paper.
引用
收藏
页码:39 / 42
页数:4
相关论文
共 50 条
  • [21] Power swing blocking (PSB) function for distance relay using prediction technique
    Koteswara Rao A.V.
    Ahmad A.
    International Journal of System Assurance Engineering and Management, 2017, 8 (2) : 301 - 307
  • [22] A Novel Unblocking Function for Distance Relay to Detect Symmetrical Faults during Power Swing
    Gawande, Prashant N.
    Dambhare, Sanjay S.
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [23] A New Technique for High Resistance Fault Detection during Power Swing for Distance Relay
    Mohamad, Nor Zulaily
    Abidin, Ahmad Farid
    AASRI CONFERENCE ON POWER AND ENERGY SYSTEMS, 2012, 2 : 50 - 55
  • [24] Symmetrical Fault Detection of Distance Relay to prevent Cascade Tripping during Power Swing
    Jeevitha, A.
    Devi, S.
    PROCEEDINGS OF 2015 ONLINE INTERNATIONAL CONFERENCE ON GREEN ENGINEERING AND TECHNOLOGIES (IC-GET), 2015,
  • [25] Qualitative Assessment of Power Swing for Enhancing Security of Distance Relay in a TCSC-Compensated Line
    Das, Sayari
    Panigrahi, Bijaya Ketan
    Jaiswal, Prajwal Kumar
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (01) : 223 - 234
  • [26] Improvement of Power Swing Detection Performance of a Distance Relay by using k-NN Algorithm
    Tekdemir, Ibrahim Gursu
    Alboyaci, Bora
    2015 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2015, : 541 - 545
  • [27] Detection of power swing and blocking the distance relay using the variance calculation of the current sampled data
    Sirus Salehimehr
    Behrooz Taheri
    Milad Faghihlou
    Electrical Engineering, 2022, 104 : 913 - 927
  • [28] Detection of power swing and blocking the distance relay using the variance calculation of the current sampled data
    Salehimehr, Sirus
    Taheri, Behrooz
    Faghihlou, Milad
    ELECTRICAL ENGINEERING, 2022, 104 (02) : 913 - 927
  • [29] Secured Relay Operations during Power Swing
    Kundu, Pratim
    Pradhan, Ashok Kumar
    2017 7TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2017, : 37 - 42
  • [30] A POWER SWING RELAY FOR PREDICTING GENERATION INSTABILITY
    BROWN, RD
    MCCLYMONT, KR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (03): : 219 - +