Does the Heparin Lock Concentration Affect Hemodialysis Catheter Patency?

被引:24
作者
Maya, Ivan D. [1 ]
Smith, Tamorie [1 ]
Allon, Michael [1 ]
机构
[1] Univ Alabama Birmingham, Div Nephrol, PB, Birmingham, AL 35233 USA
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2010年 / 5卷 / 08期
关键词
MANAGEMENT; BACTEREMIA; RISK;
D O I
10.2215/CJN.01230210
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Concentrated heparin solutions are instilled into the catheter lumens after each hemodialysis session to prevent catheter thrombosis. The heparin lock concentration at many centers has been decreased recently to reduce the risk of systemic bleeding and contain costs. However, the effect of this change on catheter patency is unknown. We compared catheter patency between two heparin lock solutions: 1000 versus 5000 units/ml. Design, setting, participants, & measurements: With use of a prospective, computerized, vascular access database, 105 patients with newly placed tunneled hemodialysis catheters, including 58 patients receiving a 5000 units/ml heparin lock and 47 patients receiving a 1000 units/ml heparin lock, were retrospectively identified. The primary endpoint was cumulative catheter patency and the secondary endpoint was frequency of thrombolytic instillation. Results: Cumulative catheter survival was similar in the two groups, being 71% versus 73% at 120 days in the low- and high-concentration heparin lock groups (hazard ratio of catheter failure, 0.97; 95% confidence interval, 0.45 to 2.09; P = 0.95). The frequency of tissue plasminogen activator instillation was significantly greater in the low-concentration heparin group (hazard ratio, 2.18; 95% Cl, 1.26 to 3.86; P = 0.005). No major bleeding complications were observed in either treatment group. The overall drug cost for maintaining catheter patency was 23% lower with the low-concentration heparin lock ($1418 versus $1917) to maintain catheter patency for 1000 days. Conclusions: Low-concentration heparin lock solutions do not decrease cumulative dialysis catheter patency, but require a twofold increase in thrombolytic instillation to maintain long-term patency. Clin J Am Soc Nephrol 5: 1458-1462, 2010. doi: 10.2215/CJN.01230210
引用
收藏
页码:1458 / 1462
页数:5
相关论文
共 20 条
[1]   A multidisciplinary approach to hemodialysis access: Prospective evaluation [J].
Allon, M ;
Bailey, R ;
Ballard, R ;
Deierhoi, MH ;
Hamrick, K ;
Oser, R ;
Rhynes, VK ;
Robbin, ML ;
Saddekni, S ;
Zeigler, ST .
KIDNEY INTERNATIONAL, 1998, 53 (02) :473-479
[2]   Current management of vascular access [J].
Allon, Michael .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 2 (04) :786-800
[3]  
[Anonymous], 2006, Am J Kidney Dis, V48, pS176, DOI [DOI 10.1053/J.AJKD.2006.04.029, 10.1053/j.ajkd.2006.04.029]
[4]   Outbreak of Adverse Reactions Associated with Contaminated Heparin [J].
Blossom, David B. ;
Kallen, Alexander J. ;
Patel, Priti R. ;
Elward, Alexis ;
Robinson, Luke ;
Gao, Ganpan ;
Langer, Robert ;
Perkins, Kiran M. ;
Jaeger, Jennifer L. ;
Kurkjian, Katie M. ;
Jones, Marilyn ;
Schillie, Sarah F. ;
Shehab, Nadine ;
Ketterer, Daniel ;
Venkataraman, Ganesh ;
Kishimoto, Takashi Kei ;
Shriver, Zachary ;
McMahon, Ann W. ;
Austen, K. Frank ;
Kozlowski, Steven ;
Srinivasan, Arjun ;
Turabelidze, George ;
Gould, Carolyn V. ;
Arduino, Matthew J. ;
Sasisekharan, Ram .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (25) :2674-2684
[5]   Comparison of Heparin-Coated and Conventional Split-Tip Hemodialysis Catheters [J].
Clark, Timothy W. I. ;
Jacobs, David ;
Charles, Hearns W. ;
Kovacs, Sandor ;
Aquino, Theresa ;
Erinjeri, Joseph ;
Benstein, Judith A. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (04) :703-706
[6]  
DEGAPUDI B, 2009, AM SOC NEPHR M SAN D
[7]  
Holley Jean L, 2007, Hemodial Int, V11, P96
[8]   Does Heparin Coating Improve Patency or Reduce Infection of Tunneled Dialysis Catheters? [J].
Jain, Gaurav ;
Allon, Michael ;
Saddekni, Souheil ;
Barker-Finkel, Jill ;
Maya, Ivan D. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 (11) :1787-1790
[9]   Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis [J].
Karaaslan, H ;
Peyronnet, P ;
Benevent, D ;
Lagarde, C ;
Rince, M ;
Leroux-Robert, C .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (10) :2072-2074
[10]   Management of hemodialysis catheter-related bacteremia with an adjunctive antibiotic lock solution [J].
Krishnasami, Z ;
Carlton, D ;
Bimbo, L ;
Taylor, ME ;
Balkovetz, DF ;
Barker, J ;
Allon, M .
KIDNEY INTERNATIONAL, 2002, 61 (03) :1136-1142