Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy

被引:34
|
作者
Fix, MK
Keller, H
Rüegsegger, P
Born, EJ
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8044 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Swiss Fed Inst Technol, CH-8044 Zurich, Switzerland
[3] Univ Bern, Inselspital, Clin Radiooncol, Div Med Radiat Phys, CH-3045 Bern, Switzerland
关键词
Monte Carlo simulation; photon dose calculation; beam model;
D O I
10.1118/1.1318220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Monte Carlo (code GEANT) produced 6 anti 15 MV phase space (PS) data were used to define several simple photon beam models. For creating the PS data the energy of starting electrons hitting the target was tuned to get correct depth dose data compared to measurements. The modeling process used the full PS information within the geometrical boundaries of the beam including all scattered radiation of the accelerator head. Scattered radiation outside the boundaries was neglected. Photons and electrons were assumed to be radiated from point sources. Four different models were investigated which involved different ways to determine the energies and locations of beam particles in the output plane. Depth dose curves, profiles, and relative output factors were calculated with these models for six field sizes from 5x5 to 40x40 cm(2) and compared to measurements. Model 1 uses a photon energy spectrum independent of location in the PS plane and a constant photon fluence in this plane. Model 2 takes into account the spatial particle fluence distribution in the PS plane. A constant fluence is used again in model 3, but the photon energy spectrum depends upon the off axis position. Model 4, finally uses the spatial particle fluence distribution and off axis dependent photon energy spectra in the PS plane. Depth dose curves and profiles for field sizes up to 10 x 10 cm(2) were not model sensitive. Good agreement between measured and calculated depth dose curves and profiles for all field sizes was reached for model 4. However, increasing deviations were found for increasing field sizes for models 1-3. Large deviations resulted for the profiles of models 2 and 3. This is due to the fact that these models overestimate and underestimate the energy fluence at large off axis distances. Relative output factors consistent with measurements resulted only for model 4. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00911-1].
引用
收藏
页码:2739 / 2747
页数:9
相关论文
共 50 条
  • [1] Photon beam description in PEREGRINE for Monte Carlo dose calculations
    Cox, LJ
    vonWittenau, AES
    Bergstrom, PM
    Mohan, R
    Libby, B
    Wu, Q
    Lovelock, DMJ
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 142 - 145
  • [2] Monte Carlo photon beam modeling and commissioning for radiotherapy dose calculation algorithm
    Toutaoui, A.
    Chikh, S. Ait
    Khelassi-Toutaoui, N.
    Hattali, B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (07): : 833 - 837
  • [3] Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom
    Farajollahi A.
    Mesbahi A.
    Radiation Medicine, 2006, 24 (4): : 269 - 276
  • [4] Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy
    Bazalova, Magdalena
    Zhou, Hu
    Keall, Paul J.
    Graves, Edward E.
    MEDICAL PHYSICS, 2009, 36 (11) : 4991 - 4999
  • [5] Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations
    Siebers, JV
    Keall, PJ
    Nahum, AE
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04): : 983 - 995
  • [6] Patient-dependent beam-modifier physics in Monte Carlo photon dose calculations
    von Wittenau, AES
    Bergstrom, PM
    Cox, LJ
    MEDICAL PHYSICS, 2000, 27 (05) : 935 - 947
  • [7] Experimental validation of the DPM Monte Carlo code for photon beam dose calculations in inhomogeneous media
    Chetty, I
    Charland, P
    Tyagi, N
    McShan, D
    Fraass, B
    Bielajew, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1351 - 1351
  • [8] On the commissioning of Monte Carlo beam models and dose profile corrections on stereotactic photon beams
    Papaconstadopoulos, P.
    Tessier, F.
    Syme, A.
    Seuntjens., J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S107 - S108
  • [9] On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV Varian photon beam
    Chibani, Omar
    Ma, C. -M. Charlie
    MEDICAL PHYSICS, 2007, 34 (04) : 1206 - 1216
  • [10] A multiple source model for 6 MV photon beam dose calculations using Monte Carlo
    Fix, MK
    Stampanoni, M
    Manser, P
    Born, EJ
    Mini, R
    Rüegsegger, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05): : 1407 - 1427