CT-guided bone marrow aspirations and biopsies: retrospective study and comparison with blind procedures

被引:6
作者
Chang, C. Y. [1 ,2 ]
Husseini, J. S. [1 ,2 ]
Moreira, A. [3 ]
Simeone, F. J. [1 ]
Yee, A. J. [2 ,4 ]
Bredella, M. A. [1 ,2 ]
Hasserjian, R. [2 ,5 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Musculoskeletal Imaging & Intervent, Boston, MA 02114 USA
[2] Harvard Med Sch, Cambridge, MA 02139 USA
[3] Ctr Hosp Sao Joao, Dept Radiol, Porto, Portugal
[4] Massachusetts Gen Hosp, Div Hematol & Oncol, Boston, MA 02114 USA
[5] Massachusetts Gen Hosp, Dept Pathol, Boston, MA 02114 USA
关键词
CT; Bone marrow; Biopsy; DEVICE; ULTRASOUND; SPECIMENS; ACCURACY;
D O I
10.1007/s00256-020-03423-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To compare the pathology results of CT-guided and blind bone marrow aspirations and biopsies. Methods Ninety-eight consecutive CT-guided biopsies and 98 age- and gender-matched blind (non-CT-guided) posterior iliac crest bone marrow aspirations and biopsies performed in 2017 were reviewed for adequacy of core biopsies and aspirate smears. CT procedure images and CT abdomen/pelvis images were reviewed to evaluate anatomic features of the posterior ilium and soft tissues. Statistical analysis was performed using a T test, Fisher exact test, and Kruskal-Wallis test. Results There was no significant difference in the age and gender of the two groups (p > 0.05). However, the CT-guided group had a higher BMI (p = 0.0049) and posterior soft tissue thickness (p = 0.0016). More CT-guided biopsy samples (CT 93 (95%); blind 77 (79%); p = 0.0006) and aspirate smears (CT 90 (92%); blind 78 (80%); p = 0.042) were categorized as adequate. The CT-guided group had longer core lengths (CT 1.4 +/- 0.6 (range 0.3-3.5) cm; blind 1.0 +/- 0.60 (range 0-2.6) cm; p = 0.0001). Overall, 131/164 (80%) of the cases had at least one of the described features (slanted posterior ilium (angle > 30 degrees), 30%; rounded posterior ilium, 20%; thick posterior ilium cortex, 13%; focal lesion in posterior ilium, 12%; prior procedure in posterior ilium, 5%; posterior soft tissue thickness > 3 cm, 40%). Conclusion CT-guided bone marrow procedures were more likely to result in both adequate aspirate smears and biopsy samples and longer core lengths when compared with blind procedures.
引用
收藏
页码:1285 / 1294
页数:10
相关论文
共 28 条
[1]   Comparison of feline core bone marrow biopsies from different sites using 2 techniques and needles [J].
Abrams-Ogg, Anthony C. G. ;
Defarges, Alice ;
Bienzle, Dorothee .
VETERINARY CLINICAL PATHOLOGY, 2014, 43 (01) :36-42
[2]  
[Anonymous], WHO CLASSIFICATION T
[3]   Using a Powered Bone Marrow Biopsy System Results in Shorter Procedures, Causes Less Residual Pain to Adult Patients, and Yields Larger Specimens [J].
Berenson, James R. ;
Yellin, Ori ;
Blumenstein, Brent ;
Bojanower, Deanna ;
Croopnick, Jonathan ;
Aboulafia, David ;
Upadhyaya, Gargi ;
Spadaccini, Cathy .
DIAGNOSTIC PATHOLOGY, 2011, 6
[4]   The ABCDs of Managing Morbidly Obese Patients in Intensive Care Units [J].
Berrios, Luis A. .
CRITICAL CARE NURSE, 2016, 36 (05) :17-26
[5]   AUDIT OF BONE-MARROW TREPHINES [J].
BISHOP, PW ;
MCNALLY, K ;
HARRIS, M .
JOURNAL OF CLINICAL PATHOLOGY, 1992, 45 (12) :1105-1108
[6]   Comparison of a powered bone marrow biopsy device with a manual system: results of a prospective randomised controlled trial [J].
Bucher, Christoph Marcus ;
Lehmann, Thomas ;
Tichelli, Andre ;
Tzankov, Alexander ;
Dirnhofer, Stephan ;
Passweg, Jakob ;
Rovo, Alicia .
JOURNAL OF CLINICAL PATHOLOGY, 2013, 66 (01) :24-28
[7]   Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning [J].
Christner, Jodie A. ;
Kofler, James M. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :881-889
[8]  
Cohen SC, 2008, ANTICANCER RES, V28, P3843
[9]   Granulomatous lesions in bone marrow: Clinicopathologic findings and significance in a study of 48 cases [J].
de Hugo, Laure Brackers ;
Ffrench, Martine ;
Broussolle, Christiane ;
Seve, Pascal .
EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2013, 24 (05) :468-473
[10]   The Effect of Obesity on Neuraxial Technique Difficulty in Pregnant Patients: A Prospective, Observational Study [J].
Ellinas, Elizabeth H. ;
Eastwood, Daniel C. ;
Patel, Smita N. ;
Maitra-D'Cruze, Anita M. ;
Ebert, Thomas J. .
ANESTHESIA AND ANALGESIA, 2009, 109 (04) :1225-1231