Three dimensional intensity modulated brachytherapy (IMBT): Dosimetry algorithm and inverse treatment planning

被引:22
作者
Shi, Chengyu [1 ,3 ]
Guo, Bingqi [1 ]
Cheng, Chih-Yao [2 ]
Esquivel, Carlos [1 ]
Eng, Tony [1 ]
Papanikolaou, Niko [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Canc Therapy & Res Ctr, San Antonio, TX 78229 USA
[2] Univ Oklahoma, Hlth Sci Ctr, Dept Radiat Oncol, Oklahoma City, OK 73104 USA
[3] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiat Oncol, Div Med Phys, San Antonio, TX 78229 USA
关键词
electronic brachytherapy (EB); intensity modulated brachytherapy (IMBT); Monte Carlo; EGSnrc; modified TG-43; RATE PROSTATE BRACHYTHERAPY; PARTIAL BREAST IRRADIATION; DOSE-RATE BRACHYTHERAPY; ELECTRONIC BRACHYTHERAPY; CONFORMITY INDEX; OPTIMIZATION; IR-192; TOXICITY; CHOICE;
D O I
10.1118/1.3456598
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. Methods: A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a "modified TG-43" (mTG-43) dose calculation formalism for IMBT dosimetry; and (3D) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an "isotropic plan" with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. Results: IMBT approaches showed superior plan quality compared to the original plans and the isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V(200) by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the target was increased by 0.13 and 0.04, respectively. The maximum dose to the skin was reduced by 56 and 28 cGy, respectively, per fraction. Also, the maximum dose to the ribs was reduced by 104 and 96 cGy, respectively, per fraction. The mean dose to the ipsilateral and contralateral breasts and lungs were also slightly reduced by the IMBT plan. The limitations of IMBT are the longer planning and delivery time. The IMBT plan took around 2 h to optimize, while the isotropic plan optimization could reach the global minimum within 5 min. The delivery time for the IMBT plan is typically four to six times longer than the corresponding isotropic plan. Conclusions: In this study, a dosimetry method for IMBT sources was proposed and an inverse treatment planning system prototype for IMBT was developed. The improvement of plan quality by 3D IMBT was demonstrated using ten APBI case studies. Faster computers and higher output of the source can further reduce plan optimization and delivery time, respectively. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3456598]
引用
收藏
页码:3725 / 3737
页数:13
相关论文
共 30 条
  • [1] Benchmarking EGSnrc in the kilovoltage energy range against experimental measurements of charged particle backscatter coefficients
    Ali, E. S. M.
    Rogers, D. W. O.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06) : 1527 - 1543
  • [2] [Anonymous], BRACHYTHERAPY
  • [3] Optimization of a breast implant in Brachytherapy PDR. Validation with Monte Carlo simulation and measurements with TLDs and GafChromic films
    Bernard, S
    Reniers, B
    Scalliet, P
    Vynckier, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 (03) : 326 - 333
  • [4] Late chest wall toxicity after MammoSite® breast brachytherapy
    Brashears, James H.
    Dragun, Anthony E.
    Jenrette, Joseph M.
    [J]. BRACHYTHERAPY, 2009, 8 (01) : 19 - 25
  • [5] Specific absorbed fractions from the image-based VIP-Man body model and EGS4-VLSI Monte Carlo code: internal electron emitters
    Chao, TC
    Xu, XG
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) : 901 - 927
  • [6] Chaswal V, 2007, BRACHYTHERAPY, V6, P78
  • [7] A dosimetric comparison of MammoSite high-dose-rate brachytherapy and Xoft Axxent electronic brachytherapy
    Dickler, Adam
    Kirk, Michael C.
    Seif, Neil
    Griem, Katherine
    Dowlatshahi, Kambiz
    Francescatti, Darius
    Abrams, Ross A.
    [J]. BRACHYTHERAPY, 2007, 6 (02) : 164 - 168
  • [8] Xoft Axxent® electronic brachytherapy-a new device for delivering brachytherapy to the breast
    Dickler, Adam
    [J]. NATURE CLINICAL PRACTICE ONCOLOGY, 2009, 6 (03): : 138 - 142
  • [9] Potential dose-conformity advantages with multi-source intensity-modulated brachytherapy (IMBT)
    Ebert M.A.
    [J]. Australasian Physical and Engineering Sciences in Medicine, 2006, 29 (02) : 165 - 171
  • [10] Possibilities for intensity-modulated brachytherapy: technical limitations on the use of non-isotropic sources
    Ebert, MA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (14) : 2495 - 2509