In vivo proton T1 relaxation times of mouse myocardial metabolites at 9.4 T

被引:5
作者
Bakermans, Adrianus J. [1 ]
Abdurrachim, Desiree [1 ]
Geraedts, Tom R. [1 ]
Houten, Sander M. [2 ,3 ]
Nicolay, Klaas [1 ]
Prompers, Jeanine J. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Biomed NMR, NL-5600 MB Eindhoven, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Clin Chem, Lab Genet Metab Dis, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Emma Childrens Hosp, Dept Pediat, NL-1105 AZ Amsterdam, Netherlands
关键词
H-1-MRS; PRESS; saturation-recovery; metabolite T-1 relaxation; myocardial metabolism; mouse heart; DEHYDROGENASE KNOCKOUT MICE; MAGNETIC-RESONANCE; LIPID-ACCUMULATION; CREATINE DEPLETION; HEART-FAILURE; SPECTROSCOPY; MR; QUANTIFICATION; CARDIOMYOPATHY; TRIGLYCERIDE;
D O I
10.1002/mrm.25340
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeProton magnetic resonance spectroscopy (H-1-MRS) for quantitative in vivo assessment of mouse myocardial metabolism requires accurate acquisition timing to minimize motion artifacts and corrections for T-1-dependent partial saturation effects. In this study, mouse myocardial water and metabolite T-1 relaxation time constants were quantified. MethodsCardiac-triggered and respiratory-gated PRESS-localized H-1-MRS was employed at 9.4 T to acquire signal from a 4-mu L voxel in the septum of healthy mice (n=10) while maintaining a steady state of magnetization using dummy scans during respiratory gates. Signal stability was assessed via standard deviations (SD) of zero-order phases and amplitudes of water spectra. Saturation-recovery experiments were performed to determine T-1 values. ResultsPhase SD did not vary for different repetition times (TR), and was 13.1 degrees 4.5 degrees. Maximal amplitude SD was 14.2%+/- 5.1% at TR=500 ms. Myocardial T-1 values (mean +/- SD) were quantified for water (1.71 +/- 0.25 s), taurine (2.18 +/- 0.62 s), trimethylamine from choline-containing compounds and carnitine (1.67 +/- 0.25 s), creatine-methyl (1.34 +/- 0.19 s), triglyceride-methylene (0.60 +/- 0.15 s), and triglyceride-methyl (0.90 +/- 0.17 s) protons. ConclusionThis work provides in vivo quantifications of proton T-1 values for mouse myocardial water and metabolites at 9.4 T. Magn Reson Med 73:2069-2074, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:2069 / 2074
页数:6
相关论文
共 32 条
  • [1] Bakermans A.J., 2013, P 21 ANN M ISMRM SAL, P2011
  • [2] Carnitine supplementation attenuates myocardial lipid accumulation in long-chain acyl-CoA dehydrogenase knockout mice
    Bakermans, Adrianus J.
    van Weeghel, Michel
    Denis, Simone
    Nicolay, Klaas
    Prompers, Jeanine J.
    Houten, Sander M.
    [J]. JOURNAL OF INHERITED METABOLIC DISEASE, 2013, 36 (06) : 973 - 981
  • [3] Fasting-Induced Myocardial Lipid Accumulation in Long-Chain Acyl-CoA Dehydrogenase Knockout Mice Is Accompanied by Impaired Left Ventricular Function
    Bakermans, Adrianus J.
    Geraedts, Tom R.
    van Weeghel, Michel
    Denis, Simone
    Ferraz, Maria Joao
    Aerts, Johannes M. F. G.
    Aten, Jan
    Nicolay, Klaas
    Houten, Sander M.
    Prompers, Jeanine J.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (05) : 558 - 565
  • [4] SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO
    BOTTOMLEY, PA
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 : 333 - 348
  • [5] THE TROUBLE WITH SPECTROSCOPY PAPERS
    BOTTOMLEY, PA
    [J]. RADIOLOGY, 1991, 181 (02) : 344 - 350
  • [6] Non-invasive magnetic-resonance detection of creatine depletion in non-viable infarcted myocardium
    Bottomley, PA
    Weiss, RG
    [J]. LANCET, 1998, 351 (9104) : 714 - 718
  • [7] Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields
    Cassidy, PJ
    Schneider, JE
    Grieve, SM
    Lygate, C
    Neubauer, S
    Clarke, K
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) : 229 - 237
  • [8] Quantitative T2 Mapping of the Mouse Heart by Segmented MLEV Phase-Cycled T2 Preparation
    Coolen, Bram F.
    Simonis, Frank F. J.
    Geelen, Tessa
    Moonen, Rik P. M.
    Arslan, Fatih
    Paulis, Leonie E. M.
    Nicolay, Klaas
    Strijkers, Gustav J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 409 - 417
  • [9] Three-dimensional T1 mapping of the mouse heart using variable flip angle steady-state MR imaging
    Coolen, Bram F.
    Geelen, Tessa
    Paulis, Leonie E. M.
    Nauerth, Arno
    Nicolay, Klaas
    Strijkers, Gustav J.
    [J]. NMR IN BIOMEDICINE, 2011, 24 (02) : 154 - 162
  • [10] Comparison of T1 Relaxation Times of the Neurochemical Profile in Rat Brain at 9.4 Tesla and 14.1 Tesla
    Cudalbu, Cristina
    Mlynarik, Vladimir
    Xin, Lijing
    Gruetter, Rolf
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 862 - 867