WEAR OF CERAMIC AND TITANIUM BALL ATTACHMENTS IN SUBJECTS WITH AN IMPLANT-RETAINED OVERDENTURE: A CONTROLLED CLINICAL TRIAL

被引:1
作者
Buettel, Adrian E. [1 ]
Luethy, Heinz [2 ]
Sendi, Pedram [1 ]
Marinello, Carlo P. [1 ]
机构
[1] Univ Basel, Sch Dent, Clin Reconstruct Dent & Temporomandibular Disorde, CH-4056 Basel, Switzerland
[2] Univ Basel, Sch Dent, Inst Mat Sci, CH-4056 Basel, Switzerland
关键词
ELECTROPLATED GOLD COPINGS; MANDIBULAR OVERDENTURES; PATIENT SATISFACTION; TELESCOPIC RETAINER; EDENTULOUS PATIENTS; REMOVABLE DENTURES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Loss of retention of implant-retained overdentures due to wear of the patrix or matrix of the attachment system is a common clinical problem. Purpose. The purpose of this controlled clinical trial was to compare the wear of ceramic and titanium ball attachments and their corresponding gold matrices after 1 year of clinical function in subjects with implant-retained mandibular overdentures. Material and methods. Forty subjects who had been treated with a 2-implant-retained overdenture received either 2 ruby ball attachments (20 subjects) or 2 titanium ball attachments (20 subjects). The diameter of the ball attachments and the thickness of the matrix were measured optically before insertion and after 1 year of clinical function. Differences among groups were then compared with the Wilcoxon rank sum test (alpha=.05). To estimate any correlation between clinical parameters and wear, the Spearman rank test was used. Results. There was no significant difference (P=.73) in the median wear of ball attachments for the titanium group (5.3 mu m; median 1.3 mu m) and for the ceramic group (1.3 mu m; median 1.3 mu m). In the ceramic group, a fracture rate of 30% was observed. The mean wear of the matrices in the titanium group was 3.1 mu m (median 6.8 mu m) and in the ceramic group 2.1 mu m (median 3.4 mu m), P=.01. No correlation was found between ball attachment wear and matrix insert wear (Spearman rank test). Wear of matrices was weakly correlated with an increase in divergence between implant axes in the sagittal plane (P=-.28 and P=.021). Ball attachment wear was associated with an increase in divergence between matrix axes in the sagittal plane (P=-.34 and P=.047). Conclusions. Matrices on ceramic ball attachments showed less wear than those placed on titanium ball attachments. However, the use of ruby ball attachments cannot be recommended because of a high fracture rate. (J Prosthet Dent 2012;107:109-113)
引用
收藏
页码:109 / 113
页数:5
相关论文
共 18 条
  • [1] Attard NJ, 2004, INT J PROSTHODONT, V17, P425
  • [2] Comparative study of four retentive anchor systems for implant supported overdentures - retention force changes
    Bayer, Stefan
    Steinheuser, Daniela
    Gruener, Manfred
    Keilig, Ludger
    Enkling, Norbert
    Stark, Helmut
    Mues, Sebastian
    [J]. GERODONTOLOGY, 2009, 26 (04) : 268 - 272
  • [3] Accounting for measurement error: A critical but often overlooked process
    Harris, Edwayd F.
    Smith, Richayd N.
    [J]. ARCHIVES OF ORAL BIOLOGY, 2009, 54 : S107 - S117
  • [4] Oral and general health-related quality of life with conventional and implant dentures
    Heydecke, G
    Locker, D
    Awad, MA
    Lund, JP
    Feine, JS
    [J]. COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 2003, 31 (03) : 161 - 168
  • [5] Ludwig K., 2006, QUINTESSENCE J DENT, V4, p46?55
  • [6] A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: Three-year results
    MacEntee, MI
    Walton, JN
    Glick, N
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01) : 28 - 37
  • [7] A controlled clinical trial of implant-retained mandibular overdentures: 10 years' results of clinical aspects and aftercare of IMZ implants and Branemark implants
    Meijer, HJA
    Raghoebar, GM
    Van't Hof, MA
    Visser, A
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 421 - 427
  • [8] Implant-retained mandibular overdentures compared with complete dentures; a 5-years' follow-up study of clinical aspects and patient satisfaction
    Meijer, HJA
    Raghoebar, GM
    Van't Hof, MA
    Geertman, ME
    Van Oort, RP
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (03) : 238 - 244
  • [9] The effects of mandibular two-implant overdentures on nutrition in elderly edentulous individuals
    Morais, JA
    Heydecke, G
    Pawliuk, J
    Lund, JP
    Feine, JS
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 (01) : 53 - 58
  • [10] Naert I, 2004, INT J PROSTHODONT, V17, P401