Enhanced heat deposition using ultrasound contrast agent - Modeling and experimental observations

被引:35
作者
Razansky, D [1 ]
Einziger, PD [1 ]
Adam, DR [1 ]
机构
[1] Technion Israel Inst Technol, Dept Biomed & Elect Engn, IL-32000 Haifa, Israel
关键词
D O I
10.1109/TUFFC.2006.1588399
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound contrast agents (UCA), created originally for visualization and diagnostic purposes, recently have been suggested as efficient enhancers of ultrasonic power deposition in tissue. The ultrasonic energy absorption by the contrast agents, considered as problematic in diagnostic imaging, might have beneficial impact in therapeutic applications such as targeted hyperthermia-based or ablation treatments. Introduction of gas microbubbles into the tissue to be treated can improve the effectiveness of current treatments by limiting the temperature rise to the treated site and minimizing the damage to the surrounding healthy tissues. To this end, proper assessment of the governing parameters of energy absorption by ultrasonically induced stabilized bubbles is important for both diagnostic and therapeutic ultrasound applications. The current study was designed to predict theoretically and measure experimentally the dissipation and heating effects of encapsulated UCA in a well-controlled and calibrated environment. The ultrasonic effects of the microbubble concentration, transmitted intensity, and frequency on power dissipation and stability of the UCA have been studied. The maximal temperature elevation obtained during 300 s experiments was 21 degrees C, in a 10 ml volume target containing UCA, insonifled by unfocused 3.2 MHz continuous wave (CW) at spatial average intensity of 1.1 W/cm(2) (182 kPa). The results also suggest that higher frequencies are more efficiently absorbed by commonly used UCA. In particular, for spatial average intensity of 1.1 W/cm(2) and concentration of 5 - 106 microspheres/cm(3), no significant reduction of UCA absorption was noticed during the first 150 s for insonation at 3.2 MHz and the first 100 s for insonation at 1 MHz. In addition, when lower average intensity of 0.5 W/cm(2) (160 kPa) at 3.2 MHz was used, the UCA absorptivity sustained for almost 200 s. Thus, when properly activated, UCA may be suitable for localized hyperthermic therapies.
引用
收藏
页码:137 / 147
页数:11
相关论文
共 38 条
[1]  
Abramowitz M., 1970, HDB MATH FUNCTIONS
[2]   Dynamics of therapeutic ultrasound contrast agents [J].
Allen, JS ;
May, DJ ;
Ferrara, KW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (06) :805-816
[3]  
ANDERSON HL, 1989, PHYS DESK REFERENCE
[4]  
Carslaw H. S., 1959, CONDUCTION HEAT SOLI
[5]   A Newtonian rheological model for the interface of microbubble contrast agents [J].
Chatterjee, D ;
Sarkar, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (12) :1749-1757
[6]   Pressure-dependent attenuation in ultrasound contrast agents [J].
Chen, Q ;
Zagzebski, J ;
Wilson, T ;
Stiles, T .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (08) :1041-1051
[7]   A comparison of the fragmentation thresholds and inertial cavitation doses of different ultrasound contrast agents [J].
Chen, WS ;
Matula, TJ ;
Brayman, AA ;
Crum, LA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01) :643-651
[8]   Mechanisms of contrast agent destruction [J].
Chomas, JE ;
Dayton, P ;
Allen, J ;
Morgan, K ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) :232-248
[9]   THE EFFECTS OF AN ELASTIC SOLID-SURFACE LAYER ON THE RADIAL PULSATIONS OF GAS-BUBBLES [J].
CHURCH, CC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (03) :1510-1521
[10]   Temperature rise recorded during lesion formation by high-intensity focused ultrasound [J].
Clarke, RL ;
terHaar, GR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :299-306