Transcatheter valve in valve implantation for failed mitral and tricuspid bioprosthesis

被引:58
|
作者
Cerillo, Alfredo Giuseppe [1 ]
Chiaramonti, Francesca [1 ]
Murzi, Michele [1 ]
Bevilacqua, Stefano [1 ]
Cerone, Elisa [2 ]
Palmieri, Cataldo [2 ]
Del Sarto, Paolo [3 ]
Mariani, Massimiliano [2 ]
Berti, Sergio [2 ]
Glauber, Mattia [1 ]
机构
[1] G Pasquinucci Hosp, G Monasterio Fdn, Operat Unit Cardiac Surg, Massa, Italy
[2] G Pasquinucci Hosp, G Monasterio Fdn, Operat Unit Cardiol, Massa, Italy
[3] G Pasquinucci Hosp, G Monasterio Fdn, Operat Unit Cardiac Anesthesia & Intens Care, Massa, Italy
关键词
TAVI; Redo valve surgery; bioprosthesis failure; REPLACEMENT; POSITION; SURGERY; SOCIETY;
D O I
10.1002/ccd.23112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We report our experience with the transapical transcatheter Valve in valve implantation (T-VIV) in patients with a failed mitral or tricuspid bioprosthesis; we briefly review the pertinent literature, and discuss some technical aspects of this procedure. Background: Redo valve surgery for failure of a mitral or tricuspid bioprosthesis might become extremely challenging, both because of the patients' condition, which is frequently poor, and for the technical aspects of the operation itself, that can be very demanding. T-VIV has been widely employed with good results for the treatment of aortic bioprosthesis failure, and could represent an attractive option in this setting. Methods: Four patients with multiple comorbidities (age: 63-83 years; logistic Euroscore: 37.2-81.5) underwent T-VIV at our institution for failure of a mitral [3] or tricuspid [1] bioprosthesis. A 26mm Sapien valve was used in all cases. All the mitral procedures were performed via a transapical approach. The tricuspid procedure was performed via a transjugular approach. Results: The first mitral procedure was complicated by the splaying of the xenograft stents and embolization of the valve. The procedure was converted to conventional surgery, and the patient died on postoperative day 1. In the subsequent procedures, the valve was positioned more atrially, and was fixed to the malfunctioning xenograft sewing ring. All subsequent procedures were successful, all patients were discharged home and were alive and well at follow-up. Conclusions: The results of T-VIV procedure in the mitral position have been suboptimal, and four of the sixteen patients reported to date died. However, all patients were extremely diseased, and some of the reported failures were related to amendable technical factors relative to the surgical access or to the valve deployment technique. With increasing experience, this procedure might become indicated as an alternative to conventional surgery in selected patients, encouraging increased use of bioprosthesis, and marking a pivotal change in the management of valvular disease. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:987 / 995
页数:9
相关论文
共 50 条
  • [41] Delayed Migration of Sapien Valve Following a Transcatheter Mitral Valve-in-Valve Implantation
    Bapat, Vinayak Nilkanth
    Khaliel, Feras
    Ihleberg, Leo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (01) : E150 - E154
  • [42] Transcatheter mitral valve stent implantation
    Lozonschi, Lucian
    Lutter, Georg
    EUROINTERVENTION, 2011, 6 (09) : 1036 - 1036
  • [43] Transcatheter tricuspid valve-in-valve implantation with bioprosthetic balloon expandable valve
    Haji-Zeinali, Ali-Mohammad
    Etesamifard, Nasrin
    Mohammadi, Zohre
    Haji-Zeinali, Mohammad-Mohsen
    Sahebjam, Mohammad
    Abbasi, Kiomars
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2022, 70 (11) : 947 - 953
  • [44] Self-expanding transcatheter aortic valve implantation for degenerated Mitroflow bioprosthesis: Early outcomes
    Pascual, Isaac
    Avanzas, Pablo
    Hernandez-Vaquero, Daniel
    Diaz, Rocio
    del Valle, Raquel
    Padron, Remigio
    Lorca, Rebeca
    Leon, Victor
    Martin, Maria
    Alfonso, Fernando
    Moris, Cesar
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 287 : 53 - 58
  • [45] Transcatheter Aortic Valve-in-Valve Implantation Using Lotus Valve for Failed Surgical Bioprostheses
    Castriota, Fausto
    Nerla, Roberto
    Micari, Antonio
    Cavazza, Caterina
    Bedogni, Francesco
    Testa, Luca
    Montorfano, Matteo
    Del Giglio, Mauro
    Cremonesi, Alberto
    ANNALS OF THORACIC SURGERY, 2017, 104 (02) : 638 - 644
  • [46] Transcatheter tricuspid valve implantation with the Cardiovalve system
    Aoi, Shunsuke
    Wiley, Jose
    Ho, Edwin
    Goldberg, Ythan
    Chau, Mei
    Latib, Azeem
    FUTURE CARDIOLOGY, 2021, 17 (06) : 963 - 969
  • [47] Commentary: Back to the future: Failed mitral valve bioprosthesis in the setting of mitral annular calcification
    Parchment, Nathaniel
    Brescia, Alexander A.
    Ailawadi, Gorav
    JTCVS TECHNIQUES, 2021, 10 : 269 - 270
  • [48] Preliminary Study of a Degenerated Tricuspid Bioprosthetic Valve Implanted via Transcatheter Valve-in-Valve Implantation Guided by 3-Dimensional Printing
    Mao, Yu
    Ma, Yanyan
    Zhai, Mengen
    Li, Lanlan
    Jin, Ping
    Liu, Yang
    Yang, Jian
    CJC OPEN, 2024, 6 (08) : 978 - 988
  • [49] Transapical transcatheter mitral valve implantation in patients with degenerated mitral bioprostheses or failed ring annuloplasty
    Zubarevich, Alina
    Szczechowicz, Marcin
    Zhigalov, Konstantin
    Marx, Philipp
    Lind, Alexander
    Janosi, Rolf Alexander
    Rassaf, Tienush
    Shehada, Sharaf-Eldin
    Malik, Rizwan
    Kamler, Markus
    Thielmann, Matthias
    Schmack, Bastian
    Ruhparwar, Arjang
    Weymann, Alexander
    Wendt, Daniel
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (05) : 674 - 682
  • [50] A meta-analysis of valve-in-valve and valve-in-ring transcatheter mitral valve implantation
    Takagi, Hisato
    Hari, Yosuke
    Kawai, Norikazu
    Ando, Tomo
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (06) : 899 - 906