An evaluation of computed tomography dose index measurements using a pencil ionisation chamber and small detectors

被引:13
作者
Anam, Choirul [1 ]
Fujibuchi, Toshioh [2 ]
Haryanto, Freddy [3 ]
Widita, Rena [3 ]
Arif, Idam [3 ]
Dougherty, Geoff [4 ]
机构
[1] Diponegoro Univ, Dept Phys, Fac Math & Nat Sci, Jl Prof Soedarto SH, Semarang 50275, Cent Java, Indonesia
[2] Kyushu Univ, Dept Hlth Sci, Fac Med Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[3] Bandung Inst Technol, Fac Math & Nat Sci, Dept Phys, Ganesha 10, Bandung 40132, West Java, Indonesia
[4] Calif State Univ Channel Isl, Dept Appl Phys & Med Imaging, Camarillo, CA 93012 USA
关键词
CT dosimetry; computed tomography dose index; small detector; small ionisation chamber; pencil ionisation chamber; CT dose profiler; WATER-EQUIVALENT DIAMETER; CONE-BEAM CT; PROFILES;
D O I
10.1088/1361-6498/aaf2b4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to compare the values of the computed tomography dose index 100 (CTDI100) obtained using two small detectors (i.e. a small ionisation chamber and a small solid state detector) with those obtained from a 100 mm pencil ionisation chamber for various input CT parameters: beam width, kVp, mAs, pitch, and head-body phantom variation. The measurement of CTDI100 using the 100 mm pencil chamber was carried out in a single rotation of axial mode, while the measurement using small detectors was carried out in helical mode. The differences of CTDI100 values obtained with two small detectors were about 7% for all variations. The differences of CTDI100 values obtained with small detectors and a 100 mm pencil ionisation chamber for beam widths of more than 4 mm were within 40%. However, for the narrowest beam widths (4 mm), the difference between them was very large (about 150%).
引用
收藏
页码:112 / 124
页数:13
相关论文
共 29 条
[1]  
AAPM, 2010, 111 AAPM
[2]  
American Association of Physicists in Medicine, 1993, 39 AAPM
[3]   Profile of CT scan output dose in axial and helical modes using convolution [J].
Anam, C. ;
Haryanto, F. ;
Widita, R. ;
Arif, I. ;
Dougherty, G. .
13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
[4]   A SIMPLE METHOD FOR CALIBRATING PIXEL VALUES OF THE CT LOCALIZER RADIOGRAPH FOR CALCULATING WATER-EQUIVALENT DIAMETER AND SIZE-SPECIFIC DOSE ESTIMATE [J].
Anam, Choirul ;
Fujibuchi, Toshioh ;
Toyoda, Takatoshi ;
Sato, Naoki ;
Haryanto, Freddy ;
Widita, Rena ;
Arif, Idam ;
Dougherty, Geoff .
RADIATION PROTECTION DOSIMETRY, 2018, 179 (02) :158-168
[5]   THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGES [J].
Anam, Choirul ;
Haryanto, Freddy ;
Widita, Rena ;
Arif, Idam ;
Dougherty, Geoff .
RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) :313-320
[6]   The impact of patient table on size-specific dose estimate (SSDE) [J].
Anam, Choirul ;
Haryanto, Freddy ;
Widita, Rena ;
Arif, Idam ;
Dougherty, Geoff ;
McLean, Donald .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) :153-158
[7]   Automated Calculation of Water-equivalent Diameter (DW) Based on AAPM Task Group 220 [J].
Anam, Choirul ;
Haryanto, Freddy ;
Widita, Rena ;
Arif, Idam ;
Dougherty, Geoff .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04) :320-333
[8]  
[Anonymous], 2011, 204 AM ASS PHYS MED
[9]  
[Anonymous], 2008, AAPM REP, DOI DOI 10.37206/97
[10]   The trouble with CTDI100 [J].
Boone, John M. .
MEDICAL PHYSICS, 2007, 34 (04) :1364-1371