Periprosthetic bone loss after insertion of an uncemented, customized femoral stem and an uncemented anatomical stem A randomized DXA study with 5-year follow-up

被引:29
作者
Nysted, Mona [1 ]
Benum, Pal [1 ,2 ]
Klaksvik, Jomar [1 ]
Foss, Olav [1 ]
Aamodt, Arild [1 ,2 ]
机构
[1] Norwegian Univ Sci & Technol, Univ Trondheim Hosp, Dept Orthopaed Surg, N-7034 Trondheim, Norway
[2] Norwegian Univ Sci & Technol, Dept Neurosci, N-7034 Trondheim, Norway
关键词
TOTAL HIP-ARTHROPLASTY; X-RAY ABSORPTIOMETRY; MINERAL DENSITY; DESIGN; IMPLANT; PROSTHESIS; DEXA; DENSITOMETRY; RESORPTION; STANDARD;
D O I
10.3109/17453674.2011.588860
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose Customized femoral stems are designed to have a perfect fit and fill in the femur in order to achieve physiological load transfer and minimize stress shielding. Dual-energy X-ray absorptiometry (DXA) is regarded as an accurate method for detection of small alterations in bone mineral density (BMD) around hip prostheses. We present medium-term DXA results from a randomized study comparing a customized and an anatomical femoral stem. Methods 100 hips were randomized to receive either the anatomical ABG-I stem or the Unique customized femoral stem, both uncemented. DXA measurements were conducted postoperatively and after 3, 6, 12, 24, 36, and 60 months, and BMD was computed for each of the 7 Gruen zones in the proximal femur. Results Results from 87 patients were available for analysis. 78 completed the 5-year follow-up: 35 patients in the ABG group and 43 patients in the Unique group. In both groups, we found the greatest degree of bone loss in the proximal Gruen zones. In zone 1, there was 15% reduction in BMD in the ABG-I group and 14% reduction in the Unique group. In zone 7, the reduction was 28% in the ABG-I group and 27% in the Unique group. The only statistically significant difference between the groups was found in Gruen zone 4, which is distal to the tip of the stem, with 1.6% reduction in BMD in the ABG-I group and 9.7% reduction in the Unique group (p = 0.003). Interpretation 5-year DXA results showed that because of stress-shielding, proximal bone loss could not be avoided-either for the anatomical ABG-I stem or for the customized Unique stem.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 39 条
[21]   The effects of cementless femoral stem shape and proximal surface texture on 'fit-and-fill' characteristics and on bone remodeling [J].
Laine, HJ ;
Poulakka, TJS ;
Moilanen, T ;
Pajamäki, KJ ;
Wirta, J ;
Lehto, MUK .
INTERNATIONAL ORTHOPAEDICS, 2000, 24 (04) :184-190
[22]   Peri-prosthetic bone density after implantation of a custom-made femoral component - A five-year follow-up [J].
Leichtle, UG ;
Leichtle, CI ;
Schmidt, B ;
Martini, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (04) :467-471
[23]   Determination of periprosthetic bone density with the DEXA method after implantation of custom-made uncemented femoral stems [J].
Martini, F ;
Sell, S ;
Kremling, E ;
Kusswetter, W .
INTERNATIONAL ORTHOPAEDICS, 1996, 20 (04) :218-221
[24]   An in vitro study of the strain distribution in human femora with anatomical and customised femoral stems [J].
Ostbyhaug, P. O. ;
Klaksvik, J. ;
Romundstad, P. ;
Aamodt, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (05) :676-682
[25]   Changes in periprosthetic bone remodelling after redesigning an anatomic cementless stem [J].
Panisello, Juan J. ;
Canales, Vicente ;
Herrero, Luis ;
Herrera, Antonio ;
Mateo, Jesus ;
Caballero, Maria J. .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (02) :373-379
[26]   Long-Term Remodeling in Proximal Femur Around a Hydroxyapatite-Coated Anatomic Stem Ten Years Densitometric Follow-Up [J].
Panisello, Juan J. ;
Herrero, Luis ;
Canales, Vicente ;
Herrera, Antonio ;
Martinez, Angel A. ;
Mateo, Jesus .
JOURNAL OF ARTHROPLASTY, 2009, 24 (01) :56-64
[27]   Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss [J].
Rahmy, AIA ;
Gosens, T ;
Blake, GM ;
Tonino, A ;
Fogelman, I .
OSTEOPOROSIS INTERNATIONAL, 2004, 15 (04) :281-289
[28]   The ABG hydroxyapatite-coated hip prosthesis - One hundred consecutive operations with average 6-year follow-up [J].
Rogers, A ;
Kulkarni, R ;
Downes, EM .
JOURNAL OF ARTHROPLASTY, 2003, 18 (05) :619-625
[29]   Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling [J].
Rosenthall, L ;
Bobyn, JD ;
Tanzer, M .
INTERNATIONAL ORTHOPAEDICS, 1999, 23 (06) :325-329
[30]   Wear in total hip and knee replacements [J].
Schmalzried, TP ;
Callaghan, JJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :115-136