Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions

被引:29
作者
Alejandro Lopez, Danian [1 ]
Duran, Alicia [2 ]
Marcela Cere, Silvia [1 ]
机构
[1] Consejo Nacl Invest Cient & Tecn, UNMdP, Inst Invest Ciencia & Tecnol Mat INTEMA, Mar Del Plata, Argentina
[2] CSIC, Inst Ceram & Vidrio, E-28049 Madrid, Spain
关键词
D O I
10.1007/s10856-007-3138-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Titanium and cobalt alloys, as well as some stainless steels, are among the most frequently used materials in orthopaedic surgery. In industrialized countries, stainless steel devices are used only for temporary implants due to their lower corrosion resistance in physiologic media when compared to other alloys. However, due to economical reasons, the use of stainless steel alloys for permanent implants is very common in developing countries. The implantation of foreign bodies is sometimes necessary in the modern medical practice. However, the complex interactions between the host and the can implant weaken the local immune system, increasing the risk of infections. Therefore, it is necessary to further study these materials as well as the characteristics of the superficial film formed in physiologic media in infection conditions in order to control their potential toxicity due to the release of metallic ions in the human body. This work presents a study of the superficial composition and the corrosion resistance of AISI 316L stainless steel and the influence of its main alloying elements when they are exposed to an acidic solution that simulates the change of pH that occurs when an infection develops. Aerated simulated body fluid (SBF) was employed as working solution at 37 C. The pH was adjusted to 7.25 and 4 in order to reproduce normal body and disease state respectively. Corrosion resistance was measured by means of electrochemical impedance spectroscopy (EIS) and anodic polarization curves.
引用
收藏
页码:2137 / 2144
页数:8
相关论文
共 19 条
  • [11] THE COMPOSITION OF THE SURFACE DURING PASSIVATION OF STAINLESS-STEELS
    OLEFJORD, I
    ELFSTROM, BO
    [J]. CORROSION, 1982, 38 (01) : 46 - 52
  • [12] SURFACE-COMPOSITION OF STAINLESS-STEEL DURING ACTIVE DISSOLUTION AND PASSIVATION
    OLEFJORD, I
    CLAYTON, CR
    [J]. ISIJ INTERNATIONAL, 1991, 31 (02) : 134 - 141
  • [13] Park J.B., 2012, BIOMATERIALS SCI ENG
  • [14] Corrosion susceptibility of implant materials Ti-5Al-4V and Ti-6Al-4Fe in artificial extra-cellular fluids
    Popa, MV
    Demetrescu, I
    Vasilescu, E
    Drob, P
    Lopez, AS
    Mirza-Rosca, J
    Vasilescu, C
    Ionita, D
    [J]. ELECTROCHIMICA ACTA, 2004, 49 (13) : 2113 - 2121
  • [15] *SCRIBN ASS INC, 1998, ZPLOT WIND EL IMP SO
  • [16] Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications
    Shih, CC
    Shih, CM
    Su, YY
    Su, LHJ
    Chang, MS
    Lin, SJ
    [J]. CORROSION SCIENCE, 2004, 46 (02) : 427 - 441
  • [17] Electric block current induced detachment from surgical stainless steel and decreased viability of Staphylococcus epidermidis
    van der Borden, AJ
    van der Mei, HC
    Busscher, H
    [J]. BIOMATERIALS, 2005, 26 (33) : 6731 - 6735
  • [18] Venugopalan R., 2001, REV CORROSION BEHAV, P99