Modelling and Simulation of Flow and Heat Transfer of Ferrofluid under Magnetic Field of Neodymium Block Magnet

被引:18
|
作者
Mousavi, S. Morteza [1 ]
Darzi, A. Ali Rabienataj [2 ]
Li, Ming [3 ]
机构
[1] Babol Noshirvani Univ Technol, Fac Mech Engn, Babol, Iran
[2] Univ Mazandaran, Dept Mech Engn, Babolsar, Iran
[3] Macquarie Univ, Sch Engn, Sydney, NSW 2109, Australia
基金
美国国家科学基金会;
关键词
Convection; Ferrofluid; FHD; MHD; Permanent magnet; BIOMAGNETIC FLUID-FLOW; NUMERICAL-SIMULATION; TRANSFER ENHANCEMENT; MIXED CONVECTION; TURBULENT-FLOW; LAMINAR; NANOFLUID; FE3O4; PIPE; HYPERTHERMIA;
D O I
10.1016/j.apm.2021.10.019
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Neodymium magnets are the strongest type of permanent magnet commercially available. This investigation aims to numerically study the behavior of ferrofluids in the presence of neodymium block magnets which could be used in a wide range of applications. The problem formulation is derived using the principles of ferrohydrodynamics (FHD) and magnetohydrodynamics (MHD), and the finite volume method is employed for solving the equations. The flow of water-Fe3O4 magnetic nanofluid at 250 <= Re <= 2300 in a three-dimensional channel under heat flux exposed to a block neodymium magnet is considered. The results indicate that the magnet can significantly affect the flow field and heat transfer while FHD effects are completely dominant and MHD effects are ignorable. In the presence of the magnet, a secondary flow is created, which is more significant for low Reynolds numbers. Applying the magnetic field increases the heat transfer so that at Re=250, where the heat transfer is low, it can increase the Nusselt number by a factor of 2. Moreover, the magnetic field substantially increases the wall skin friction. Considering both the increments of heat transfer and friction, the Reynolds number of 1500 has the maximum thermal performance factor. With increasing Reynolds number or distance between the magnet and channel, the magnetic effect decreases. It is found that the thermal performance factor is increased by reducing the distance of the magnet and channel. In addition, if the height of the magnet is decreased by half (from 1 cm to 0.5 cm), the thermal performance factor improves by 6%. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:238 / 260
页数:23
相关论文
共 50 条
  • [31] Heat transfer enhancement of ferrofluid flow within a wavy channel by applying a non-uniform magnetic field
    Mousavi, S. Morteza
    Biglarian, Mohit
    Darzi, A. Ali Rabienataj
    Farhadi, Mousa
    Afrouzi, Hamid Hassanzadeh
    Toghraie, Davood
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 139 (05) : 3331 - 3343
  • [32] On saturated flow boiling heat transfer of deionized water/ferrofluid on structured surfaces with or without external magnetic field
    Benam, Behnam Parizad
    Mohammadilooey, Mandana
    Sadaghiani, Abdolali
    Cakir, Ece
    Acar, Havva Yagci
    Park, Hyun Sun
    Kosar, Ali
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2025, 236
  • [33] Heat transfer enhancement of a fin-and-tube compact heat exchanger by employing magnetite ferrofluid flow and an external magnetic field
    Bezaatpour, Mojtaba
    Rostamzadeh, Hadi
    APPLIED THERMAL ENGINEERING, 2020, 164
  • [34] CFD modeling and sensitivity analysis of heat transfer enhancement of a ferrofluid flow in the presence of a magnetic field
    Ghorbani, Babak
    Ebrahimi, Sasan
    Vijayaraghavan, Krishna
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 544 - 552
  • [35] Heat exchange enhancement of ferrofluid flow into rectangular channel in the presence of a magnetic field
    Mehrez, Zouhaier
    El Cafsi, Afif
    APPLIED MATHEMATICS AND COMPUTATION, 2021, 391 (391)
  • [36] Magnetite water based ferrofluid flow and convection heat transfer on a vertical flat plate: Mathematical and statistical modelling
    Yasin, Siti Hanani Mat
    Mohamed, Muhammad Khairul Anuar
    Ismail, Zulkhibri
    Salleh, Mohd Zuki
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 40
  • [37] Heat transfer in MHD stagnation point flow of a ferrofluid over a stretchable rotating disk
    Mustafa, Irfan
    Javed, Tariq
    Ghaffari, Abuzar
    JOURNAL OF MOLECULAR LIQUIDS, 2016, 219 : 526 - 532
  • [38] Effect of non-uniform magnetic field on heat transfer of swirling ferrofluid flow inside tube with twisted tapes
    Mokhtari, Mojtaba
    Hariri, Saman
    Gerdroodbary, M. Barzegar
    Yeganeh, Rezvan
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2017, 117 : 70 - 79
  • [39] Water-based ferrofluid flow and heat transfer over a stretchable rotating disk under the influence of an alternating magnetic field
    Bhandari, Anupam
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2021, 235 (12) : 2201 - 2214
  • [40] Heat transfer enhancement of Fe3O4 ferrofluids in the presence of magnetic field
    Fadaei, Farzad
    Shahrokhi, Mohammad
    Dehkordi, Asghar Molaei
    Abbasi, Zeinab
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2017, 429 : 314 - 323