Glass Fiber Reinforced Composite Orthodontic Retainer: In Vitro Effect of Tooth Brushing on the Surface Wear and Mechanical Properties

被引:16
作者
Sfondrini, Maria Francesca [1 ]
Vallittu, Pekka Kalevi [2 ,3 ]
Lassila, Lippo Veli Juhana [2 ,3 ]
Viola, Annalisa [1 ]
Gandini, Paola [1 ]
Scribante, Andrea [1 ]
机构
[1] Univ Pavia, Dept Clin Surg Diagnost & Paediat Sci, Unit Orthodont & Paediat Dent, Sect Dent, I-27100 Pavia, Italy
[2] Univ Turku, Inst Dent, Dept Biomat Sci, Turku 20100, Finland
[3] Univ Turku, Inst Dent, TCBC, Turku 20100, Finland
关键词
FRC; bonding; technique; fiber; reinforced; composite; spot; mechanical; deflection; orthodontics; brushing; wear; retainer; splint; load; FLEXURAL PROPERTIES; NANOFILLERS; RETENTION;
D O I
10.3390/ma13051028
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Fiber reinforced composites (FRCs) are metal free materials that have many applications in dentistry. In clinical orthodontics, they are used as retainers after active treatment in order to avoid relapse. However, although the modulus of the elasticity of FRCs is low, the rigidity of the material in the form of a relatively thick retainer with a surface cover of a flowable resin composite is known to have higher structural rigidity than stainless steel splints. The aim of the present study is to measure load and bending stress of stainless steel wires, as well as flowable resin composite covered and spot-bonded FRC retainer materials after tooth brushing. These materials were tested with a three point bending test for three different conditions: no brushing, 26 min of brushing, and 60 min of brushing. SEM images were taken before and after different times of tooth brushing. Results showed that stainless steel was not significantly affected by tooth brushing. On the other hand, a significant reduction of values at maximum load at fracture was reported for both FRC groups, and uncovered FRCs were most affected. Concerning maximum bending stress, no significant reduction by pretreatment conditions was reported for the materials tested. SEM images showed no evident wear for stainless steel. Flowable resin composite covered FRCs showed some signs of composite wear, whereas spot-bonded FRCs, i.e., without the surface cover of a flowable resin composite, showed signs of wear on the FRC and exposed glass fibers from the FRC's polymer matrix. Because of the significant changes of the reduction of maximum load values and the wear for spot-bonded FRCs, this technique needs further in vitro and in vivo tests before it can be performed routinely in clinical practice.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Glass Fiber-Reinforced Dental Bridges - Clinical and Mechanical Properties
    Beldiman, Maria-Antonela
    Luca, Elena
    Ioanid, Nicoleta
    Bosinceanu, Dana-Gabriela
    Bosinceanu, Dan-Nicolae
    2017 IEEE INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2017, : 527 - 530
  • [32] The effect of water storage on the bending properties of esthetic, fiber-reinforced composite orthodontic archwires
    Chang, Ju-Han
    Berzins, David W.
    Pruszynski, Jessica E.
    Ballard, Richard W.
    ANGLE ORTHODONTIST, 2014, 84 (03) : 417 - 423
  • [33] Effect of Surface Treatment and BN Content on the Mechanical Properties of Aluminum Laminates Reinforced with Glass Fiber and Epoxy Resin
    Huang, Linhua
    Li, Song
    Guo, Enping
    POWDER METALLURGY AND METAL CERAMICS, 2024, 62 (11-12) : 684 - 695
  • [34] Wear and mechanical properties of short carbon fiber reinforced copper matrix composites
    Yang, Lianwei
    Dong, Yun
    Wang, Ruijie
    ADVANCED MATERIALS AND COMPUTER SCIENCE, PTS 1-3, 2011, 474-476 : 1605 - +
  • [35] The Effect of Resin Matrix Composition on Mechanical Properties of E-glass Fiber-Reinforced Composite for Dental Use
    Zhang, Meng
    Matinlinna, Jukka Pekka
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2011, 25 (19) : 2687 - 2701
  • [36] Glass fiber reinforced PLA composite with enhanced mechanical properties, thermal behavior, and foaming ability
    Wang, Guilong
    Zhang, Dongmei
    Wan, Gengping
    Li, Bo
    Zhao, Guoqun
    POLYMER, 2019, 181
  • [37] Characterization of Mechanical Properties of Epoxy Reinforced with Glass Fiber and Coconut Fiber
    Marimuthu, Prakash K.
    Kumar, Mohan S.
    Kumar, Ravi, V
    Govindaraju, H. K.
    MATERIALS TODAY-PROCEEDINGS, 2019, 16 : 661 - 667
  • [38] Prediction of wear of short glass fiber reinforced polyamide 66 composite sprocket
    Sivakumar, K.
    Timmaraju, Mallina Venkata
    Gnanamoorthy, R.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2024,
  • [39] Effect of composite coating on interfacial properties of glass fiber reinforced polyamide 6 composites
    Wang G.
    Jin Z.
    Song J.
    Li R.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2023, 40 (12): : 6668 - 6680
  • [40] Effect of the Glass Fiber Content of a Polybutylene Terephthalate Reinforced Composite Structure on Physical and Mechanical Characteristics
    Hamlaoui, Oumayma
    Klinkova, Olga
    Elleuch, Riadh
    Tawfiq, Imad
    POLYMERS, 2022, 14 (01)