Do trabecular metal cups achieve better results when compared to hemispherical porous titanium cups in acetabular revision surgery?

被引:5
作者
Cruz-Pardos, Ana [1 ]
Garcia-Rey, Eduardo [1 ]
Fernandez-Fernandez, Ricardo [1 ]
Ortega-Chamarro, Jose [1 ]
机构
[1] Hosp La Paz, Dept Orthopaed, Paseo Castellana 261, Madrid 28046, Spain
关键词
acetabular revision; titanium cups; trabecular cups; TOTAL HIP-ARTHROPLASTY; CONCISE FOLLOW-UP; TERM SURVIVAL; TANTALUM; COMPONENTS; RECONSTRUCTION; REPLACEMENT; 50-PERCENT; MINIMUM; DEFECTS;
D O I
10.1177/1120700020919943
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Trabecular metal (TM) cups were introduced in order to achieve better ingrowth and stability of the cup in acetabular revision surgery. As their use has evolved over time, we have queried whether TM cups would improve results in terms of the rate of aseptic loosening when compared to historical uncemented porous titanium cups used in revision surgery for acetabular bone loss in Hospital La Paz (Madrid, Spain). Methods: We retrospectively reviewed 197 acetabular revisions performed between 1991 and 2015. Titanium cups were used in 81 cases and TM cups in 116. The mean follow-up was 8.1 years (range 1-15); 12.0 +/- 7.8 for titanium group and 5.4 +/- 3.1 for TM group. The most common reason for revision was aseptic loosening. A Kaplan-Meier analysis was used to determine the survival of the cup, with radiological failure and re-revision due to aseptic loosening as the endpoints. Cox multivariate regression analyses were performed to assess different risk factors for failure. Results: 1 TM cup and 1 titanium cup were re-revised due to aseptic loosening (p = 0.61). Radiological cup loosening was observed in 4 TM cups and 2 titanium cups (p = 1.0). At 6 years, the probability of not having radiological cup loosening was 97.4% (95% CI, 93.9-100) for the titanium cups and 95.1% for the TM cups (95% CI, 90.1-99.9) (p = 0.59). Another 5 cups were re-revised due to dislocation. Hips with a greater Paprosky defect showed a higher risk of loosening (p < 0.05, hazard risk (HR) 3.04; 95% CI, 0.97-9.54). Conclusions: This study shows there was no significant difference in re-revision due to aseptic loosening or radiological loosening between titanium and TM cups in revision surgery for acetabular bone loss. Both types of cups demonstrate excellent results with a low failure rate and minimal complications.
引用
收藏
页码:774 / 781
页数:8
相关论文
共 34 条
  • [1] Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss
    Abolghasemian, M.
    Tangsataporn, S.
    Sternheim, A.
    Backstein, D.
    Safir, O.
    Gross, A. E.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (02) : 166 - 172
  • [2] Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
    Bobyn, JD
    Stackpool, GJ
    Hacking, SA
    Tanzer, M
    Krygier, JJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05): : 907 - 914
  • [3] BOBYN JD, 1980, CLIN ORTHOP RELAT R, P291
  • [4] Short to Midterm Follow-Up of the Tritanium Primary Acetabular Component: A Cause for Concern
    Carli, Alberto V.
    Warth, Lucian C.
    Bentley, Karen L. de Mesy
    Nestor, Bryan J.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (02) : 463 - 469
  • [5] FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS
    DAUBIGNE, RM
    POSTEL, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) : 451 - 475
  • [6] Trabecular Metal Used for Major Bone Loss in Acetabular Hip Revision
    Davies, Jonah Hebert
    Laflamme, G. Yves
    Delisle, Josee
    Fernandes, Julio
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1245 - 1250
  • [7] DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
  • [8] Revision of the acetabular component without cement after total hip arthroplasty - A concise follow-up, at fifteen to nineteen years, of a previous report
    Della Valle, CJ
    Shuaipaj, T
    Berger, RA
    Rosenberg, AG
    Shott, S
    Jacobs, JJ
    Galante, JO
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) : 1795 - 1800
  • [9] Radiographic anatomic structure of the arthritic acetabulum and its influence on total hip arthroplasty
    Dorr, LD
    Bechtol, CO
    Watkins, RG
    Wan, ZN
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (07) : 890 - 900
  • [10] Revision of Failed Total Hip Arthroplasty Acetabular Cups to Porous Tantalum Components A 5-Year Follow-Up Study
    Fernandez-Fairen, Mariano
    Murcia, Antonio
    Blanco, Agustin
    Merono, Antonio
    Murcia, Antonio, Jr.
    Ballester, Jorge
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (06) : 865 - 872