Simple Proposal for Dosimetry with an Elekta iViewGT™ Electronic Portal Imaging Device (EPID) Using Commercial Software Modules

被引:0
作者
Liebich, Janett [1 ]
Licher, Joerg [1 ]
Scherf, Christian [1 ]
Kara, Eugen [1 ]
Koch, Nadine [1 ]
Roedel, Claus [1 ]
Ramm, Ulla [1 ]
机构
[1] Klinikum Johann Wolfgang Goethe Univ Frankfurt Ma, Zentrum Radiol, Klin Strahlentherapie & Onkol, Frankfurt, Germany
关键词
EPID dosimetry; Amorphous silicon EPID; IMRT verification; Dose response; INTENSITY-MODULATED RADIOTHERAPY; DOSE-RESPONSE; IMRT; FIELD; VERIFICATION; CALIBRATION; RADIATION; MATRIX; MODEL;
D O I
10.1007/s00066-011-2176-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: An electronic portal imaging device (EPID) is used to control for patient setup and positioning during fractionated radiotherapy. Due to the rising complexity and conformity of irradiation techniques, the demand for an accurate verification of the dose delivered to the patient has also increased. The purpose of this study was to investigate a simple guidance for dosimetry with an Elekta iViewGT (TM) EPID using commercial software modules. Material and Methods: EPID measurements were performed using an Elekta iViewGT (TM) EPID on a linear accelerator with 6 MV x-ray beam. The EPID signal was studied for reproducibility, as well as characteristics as a function of dose, dose rate, and field size. A series of experiments, comparing the response of the flat panel imager and ionization chamber measurements of dose, determine the parameters for the calibration model. EPID measurements were also compared with calculations of the treatment planning system. Results: We found a stable response of the EPID signal over a period of 14 months. It showed nonlinearity depending on dose up to 6.8%. There were low oscillations up to 1.2% depending on dose rate. For all fields, the calibrated flat panel profiles match the measured and calculated dose profiles with maximum deviation of 2-3% for the in-field region. In the high gradient areas, higher differences up to 6% were found. Conclusions: The gamma evaluation indicates good correlation between predicted and acquired EPID images. The EPID-based pretreatment IMRT verification method will help to improve the quality assurance procedure.
引用
收藏
页码:316 / 321
页数:6
相关论文
共 27 条
  • [1] Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation
    Bednarz, Bryan
    Xu, X. George
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (04) : N43 - N57
  • [2] The dose response relationship of a liquid-filled electronic portal imaging device
    Boellaard, R
    vanHerk, M
    Mijnheer, BJ
    [J]. MEDICAL PHYSICS, 1996, 23 (09) : 1601 - 1611
  • [3] Calibration of an amorphous-silicon flat panel portal imager for exit-beam dosimetry
    Chen, J
    Chuang, CF
    Morin, O
    Aubin, M
    Pouliot, J
    [J]. MEDICAL PHYSICS, 2006, 33 (03) : 584 - 594
  • [4] Comprehensive fluence model for absolute portal dose image prediction
    Chytyk, K.
    McCurdy, B. M. C.
    [J]. MEDICAL PHYSICS, 2009, 36 (04) : 1389 - 1398
  • [5] Transmission dosimetry with a liquid-filled electronic portal imaging device
    Essers, M
    Boellaard, R
    vanHerk, M
    Lanson, H
    Mijnheer, B
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (04): : 931 - 941
  • [6] Dosimetric characteristics of a liquid-filled electronic portal imaging device
    Essers, M
    Hoogervorst, BR
    vanHerk, M
    Lanson, H
    Mijnheer, BJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1265 - 1272
  • [7] Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams
    Greer, Peter B.
    Vial, Philip
    Oliver, Lyn
    Baldock, Clive
    [J]. MEDICAL PHYSICS, 2007, 34 (11) : 4389 - 4398
  • [8] Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device
    Greer, Peter B.
    [J]. MEDICAL PHYSICS, 2007, 34 (10) : 3815 - 3824
  • [9] Jacob V, 2009, STRAHLENTHER ONKOL, V185, P34, DOI 10.1007/s00066-009-1879-x
  • [10] Assessment of dosimetrical performance in 11 Varian a-Si500 electronic portal imaging devices
    Kavuma, Awusi
    Glegg, Martin
    Currie, Garry
    Elliott, Alex
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23) : 6893 - 6909