Experimental study on thermal performance of a mobilized thermal energy storage system: A case study of hydrated salt latent heat storage

被引:34
作者
Wang, Yan [1 ]
Yu, Kaixiang [1 ]
Ling, Xiang [1 ]
机构
[1] Nanjing Tech Univ, Sch Mech & Power Engn, Nanjing 211816, Peoples R China
基金
中国国家自然科学基金;
关键词
Mobilized thermal energy storage system; Charging and discharging time; Indirect-contact; Phase change material; PHASE-CHANGE MATERIALS; SODIUM-ACETATE TRIHYDRATE; RELEASE PERFORMANCE; PCM; TRANSPORTATION; ENHANCEMENT; IMPROVEMENT; EXCHANGER; CONTAINER;
D O I
10.1016/j.enbuild.2019.109744
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A mobilized thermal energy storage (M-TES) system was proposed to utilize the renewable energy or recover the industrial waste heat in this paper. The M-TES system with 215 kg sodium acetate trihydrate as phase change material (PCM) filled into a tube-in-tank heat exchanger was designed and experimental tests were conducted to evaluate its thermal performance. The charging-discharging behavior of M-TES system was observed and temperature evolutions of PCM and heat transfer fluid (HTF) were monitored. The charging process of the M-TES system could be accomplished in 1200 s; while for energy discharging process, it took a little longer (1400 s) due to the prevention of natural convection. It also revealed that the non-uniform temperature distribution of PCM would result in asynchrony of melting/solidification. The PCM in the middle part of the tubes would melt at first, whereas the temperature of the PCM close to the end of the tubes increased much slower. The temperature difference was much more significant during the discharging process. Super cooling could be found easily for the PCM in the ends of tubes. The released heat in the discharging process was applied to heat the cooling water to mimic the domestic consumption of hot water to investigate the thermal performance of energy discharging. With perfect performance of our indirect contact heat exchanger, the thermal efficiency was estimated of 79.4%. Our tests would provide an experimental basis for the application of the low-temperature mobilized LHTES system. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 32 条
[1]   Phase change materials and carbon nanostructures for thermal energy storage: A literature review [J].
Amaral, C. ;
Vicente, R. ;
Marques, P. A. A. P. ;
Barros-Timmons, A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 79 :1212-1228
[2]   Thermal energy storage for low and medium temperature applications using phase change materials - A review [J].
da Cunha, Jose Pereira ;
Eames, Philip .
APPLIED ENERGY, 2016, 177 :227-238
[3]  
Doebelin E.O., 1990, Measurement Systems, Application and Design
[4]   Sodium acetate trihydrate-chitin nanowhisker nanocomposites with enhanced phase change performance for thermal energy storage [J].
Fashandi, Maryam ;
Leung, Siu N. .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2018, 178 :259-265
[5]  
Fujita Y., 2006, IEA ECES ANN 18 1 WO
[6]   Experiments on thermal performance of erythritol/expanded graphite in a direct contact thermal energy storage container [J].
Gao, Liuhua ;
Zhao, Jun ;
An, Qingsong ;
Zhao, Dong ;
Meng, Feng ;
Liu, Xueling .
APPLIED THERMAL ENGINEERING, 2017, 113 :858-866
[7]   Techno-economic assessment of mobilized thermal energy storage for distributed users: A case study in China [J].
Guo, Shaopeng ;
Zhao, Jun ;
Wang, Weilong ;
Yan, Jinyue ;
Jin, Guang ;
Wang, Xiaotong .
APPLIED ENERGY, 2017, 194 :481-486
[8]   Numerical study of the improvement of an indirect contact mobilized thermal energy storage container [J].
Guo, Shaopeng ;
Zhao, Jun ;
Wang, Weilong ;
Yan, Jinyue ;
Jin, Guang ;
Zhang, Zhiyu ;
Gu, Jie ;
Niu, Yonghong .
APPLIED ENERGY, 2016, 161 :476-486
[9]   Experimental study on solving the blocking for the direct contact mobilized thermal energy storage container [J].
Guo, Shaopeng ;
Zhao, Jun ;
Wang, Weilong ;
Jin, Guang ;
Wang, Xiaotong ;
An, Qingsong ;
Gao, Wei .
APPLIED THERMAL ENGINEERING, 2015, 78 :556-564
[10]   Numerical simulation study on optimizing charging process of the direct contact mobilized thermal energy storage [J].
Guo, Shaopeng ;
Li, Hailong ;
Zhao, Jun ;
Li, Xun ;
Yan, Jinyue .
APPLIED ENERGY, 2013, 112 :1416-1423