Performance investigation of the natural draft wet cooling tower at different wet-bulb temperatures

被引:0
作者
Raj, Gaurav [1 ]
Chandra, Prakash [1 ]
Pathak, Piyush Kumar [1 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Patna, Bihar, India
关键词
Shade; wet-bulb temperature; tripal; aluminium-zinc alloy-coated steel sheet; correlation; regression equation; THERMAL PERFORMANCE; DRY; NANOFLUID; WALL;
D O I
10.1080/01430750.2021.1995487
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This work experimentally investigated a natural draft wet cooling tower by varying the wet-bulb temperatures by shading. In this work, inlet air conditions were changed by shading of it using tripal and aluminium-zinc alloy-coated steel sheets at different water to air flow rate (L/G) ratios. It is observed that shading of cooling tower with tripal increases the tower characteristics up to 1.43 L/G ratio, whereas it increases up to 1.61 L/G ratio, when it is shaded with a steel sheet. Tripal shades increase the tower characteristics from 0.62% to 4.45% up to an L/G ratio of 1.43. Similarly, the steel sheet shading increases the tower characteristics from 1.46% to 14.48% up to an L/G ratio of 1.61. Finally, regression equations were developed for the coefficient of efficiency and water temperature difference with water flow rate at different wet-bulb temperatures.
引用
收藏
页码:5864 / 5872
页数:9
相关论文
共 30 条
  • [1] Feasibility study for reduce water evaporative loss in a power plant cooling tower by using air to Air heat exchanger with auxiliary Fan
    Deziani, M.
    Rahmani, Kh.
    Roudaki, S. J. Mirrezaei
    Kordloo, M.
    [J]. DESALINATION, 2017, 406 : 119 - 124
  • [2] Influence of non-uniform layout fillings on thermal performance for wet cooling tower
    Gao, Ming
    Zhang, Lei
    Wang, Ni-ni
    Shi, Yue-tao
    Sun, Feng-zhong
    [J]. APPLIED THERMAL ENGINEERING, 2016, 93 : 549 - 555
  • [3] Alternative geometry for cylindrical natural draft cooling tower with higher cooling efficiency under crosswind condition
    Goodarzi, M.
    Ramezanpour, R.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 77 : 243 - 249
  • [4] Thermal performance of cross flow cooling towers in variable wet bulb temperature
    Hajidavalloo, Ebrahim
    Shakeri, Reza
    Mehrabian, Mozaffar A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (06) : 1298 - 1303
  • [5] Comparative study on the performance of natural draft dry, pre-cooled and wet cooling towers
    He, Suoying
    Gurgenci, Hal
    Guan, Zhiqiang
    Hooman, Kamel
    Zou, Zheng
    Sun, Fengzhong
    [J]. APPLIED THERMAL ENGINEERING, 2016, 99 : 103 - 113
  • [6] Experimental Investigation of Al2O3/Water Nanofluid Through Equilateral Triangular Duct With Constant Wall Heat Flux in Laminar Flow
    Heris, Saeed Zeinali
    Edalati, Zahra
    Noie, Seyed Hossein
    Mahian, Omid
    [J]. HEAT TRANSFER ENGINEERING, 2014, 35 (13) : 1173 - 1182
  • [7] Experimental investigation of the effect of different nanofluids on the thermal performance of a wet cooling tower using a new method for equalization of ambient conditions
    Imani-Mofrad, Peyman
    Heris, Saeed Zeinali
    Shanbedi, Mehdi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 158 : 23 - 35
  • [8] Experimental investigation of filled bed effect on the thermal performance of a wet cooling tower by using ZnO/water nanofluid
    Imani-Mofrad, Peyman
    Saeed, Zeinali Heris
    Shanbedi, Mehdi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 127 : 199 - 207
  • [9] Optimizing the effect of concentration and flow rate of water/MWCNTs nanofluid on the performance of a forced draft cross-flow cooling tower
    Javadpour, Reza
    Heris, Saeed Zeinali
    Mohammadfam, Yaghoub
    [J]. ENERGY, 2021, 217
  • [10] Kim HY, 2018, RESTOR DENT ENDOD, V43, P4