An Observer-Based Diagnosis Scheme for Single and Simultaneous Open-Switch Faults in Induction Motor Drives

被引:187
作者
Campos-Delgado, D. U. [1 ]
Espinoza-Trejo, D. R. [2 ]
机构
[1] Univ Autonoma San Luis Potosi, Fac Ciencias, San Luis Potosi 78290, Mexico
[2] Univ Autonoma San Luis Potosi, Coordinac Acad Reg Altiplano, Matehuala 78700, Mexico
关键词
Fault diagnosis; induction motor (IM); nonlinear observers; three-phase inverter; PWM INVERTER; SPEED DRIVES; SYSTEM; MODES;
D O I
10.1109/TIE.2010.2047829
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, the detection and isolation of open-switch faults in induction motor (IM) drives are addressed from a model-based perspective. Residuals are synthesized by using nonlinear observers followed from a directional characterization. First, it is observed that the IM model can be written in a recurrent decoupled structure by taking the stator currents and mechanical velocity as outputs. In this way, residuals can be insensitive to load torque and operating conditions, and simultaneous faults can be addressed. A pulsewidth modulation three-phase inverter is studied as power actuator for the IM. Hence, in order to isolate faults related to the six switching devices, a directional residual evaluation in the dq-frame is employed. Hence, three residuals are constructed to isolate the faulty switches. The ideas presented in this paper are validated experimentally in a test bench of 1-hp IM under single and simultaneous faults.
引用
收藏
页码:671 / 679
页数:9
相关论文
共 31 条
[1]   Advances in Diagnostic Techniques for Induction Machines [J].
Bellini, Alberto ;
Filippetti, Fiorenzo ;
Tassoni, Carta ;
Capolino, Gerard-Andre .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) :4109-4126
[2]   A review of induction motors signature analysis as a medium for faults detection [J].
Benbouzid, ME .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :984-993
[3]   What stator current processing-based technique to use for induction motor rotor faults diagnosis? [J].
Benbouzid, MEH ;
Kliman, GB .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (02) :238-244
[4]   Fault-tolerant control in variable speed drives: a survey [J].
Campos-Delgado, D. U. ;
Espinoza-Trejo, D. R. ;
Palacios, E. .
IET ELECTRIC POWER APPLICATIONS, 2008, 2 (02) :121-134
[5]   Development of a tool wear observer model for online tool condition monitoring and control in machining nickel-based alloys [J].
Chen, X. Q. ;
Li, H. Z. .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2009, 45 (7-8) :786-800
[6]   An induction motor drive system with improved fault tolerance [J].
Corrêa, MBD ;
Jacobina, CB ;
da Silva, ERC ;
Lima, AMN .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (03) :873-879
[7]   A geometric approach to nonlinear fault detection and isolation [J].
De Persis, C ;
Isidori, A .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2001, 46 (06) :853-865
[8]   Actuator faults diagnosis for a class of nonlinear systems applied to electric motors drives [J].
Espinoza-Trejo, D. R. ;
Campos-Delgado, D. U. .
2008 AMERICAN CONTROL CONFERENCE, VOLS 1-12, 2008, :2154-+
[9]  
Fuchs FW, 2003, IEEE IND ELEC, P1378
[10]   Medium-voltage adjustable-speed drives - Users' and manufacturers' experiences [J].
Hanna, RA ;
Prabhu, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (06) :1407-1415