Direct Quantification of Breast Dose During Coronary CT Angiography and Evaluation of Dose Reduction Strategies

被引:19
作者
Abadi, Sobhi [1 ]
Mehrez, Hatem [2 ,5 ]
Ursani, Ali [3 ]
Parker, Mark [4 ]
Paul, Narinder [1 ]
机构
[1] Univ Hlth Network, Toronto Gen Hosp, Dept Med Imaging, Toronto, ON M5G 2N2, Canada
[2] Toshiba Med Syst, Markham, ON, Canada
[3] Toronto Gen Hosp, Dept Med Engn, Toronto, ON, Canada
[4] VCU Med Ctr, Dept Med Imaging, Richmond, VA USA
[5] Toshiba Canada Ltd, Calgary, AB, Canada
关键词
64-MDCT; 320-MDCT; breast radiation dose; coronary CT angiography; Gafchromic film; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; IMAGE QUALITY; ENERGY-DEPENDENCE; FEMALE BREAST; KILOVOLTAGE; SCANNER; DOSIMETRY; PROTOCOL;
D O I
10.2214/AJR.10.4626
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to quantify the absorbed radiation dose received by the adult female breast during coronary CT angiography (CTA) and to evaluate the effectiveness of various dose reduction strategies. MATERIALS AND METHODS. An adult female thoracic anthropomorphic phantom was scanned using eight different clinical coronary CTA protocols that varied in detector configuration (320 x 0.5 mm or 64 x 0.5 mm), x-ray tube activation (full R-R, 65% R-R, or 70-80% R-R), use of tube current modulation, and use of breast shields. Direct dosimetry measurements were performed using Gafchromic film to determine the absorbed breast dose. RESULTS. Retrospective helical data acquisition using a 64-detector array and a full cardiac cycle without dose modulation or breast shielding is associated with an average absorbed breast dose of 82.9 mGy. Optimization of coronary CTA technique using a 320-detector array and a 70-80% cardiac phase reduces the absorbed breast dose by 78.9% to 17.5 mGy, whereas breast shields used in isolation reduces breast dose by up to 46.8%. CONCLUSION. The implementation of clinically validated coronary CTA protocols using large-area detector acquisition and prospective ECG gating with limited x-ray tube activation results in substantial breast dose savings of up to 78.9% and should be used whenever possible in combination with bismuth breast shields to achieve further dose reduction.
引用
收藏
页码:W152 / W158
页数:7
相关论文
共 34 条
  • [1] MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose
    Abada, Hicham T.
    Larchez, Christophe
    Daoud, Beatrice
    Sigal-Cinqualbre, Anne
    Paul, Jean-Francois
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) : S387 - S390
  • [2] [Anonymous], 2008, PRESENT PRACTICES FU
  • [3] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [4] Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies
    Chiu-Tsao, ST
    Ho, Y
    Shankar, R
    Wang, L
    Harrison, LB
    [J]. MEDICAL PHYSICS, 2005, 32 (11) : 3350 - 3354
  • [5] Coronary computed tomography angiography as a screening tool for the detection of occult coronary artery disease in asymptomatic individuals
    Choi, Eue-Keun
    Choi, Sang Il
    Rivera, Juan J.
    Nasir, Khurram
    Chang, Sung-A
    Chun, Eun Ju
    Kim, Hyung-Kwan
    Choi, Dong-Joo
    Blumenthal, Roger S.
    Chang, Hyuk-Jae
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (05) : 357 - 365
  • [6] Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation
    Christner, Jodie A.
    Zavaletta, Vanessa A.
    Eusemann, Christian D.
    Walz-Flannigan, Alisa I.
    McCollough, Cynthia H.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : W49 - W55
  • [7] Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    Einstein, Andrew J.
    Henzlova, Milena J.
    Rajagopalan, Sanjay
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03): : 317 - 323
  • [8] Clinical use of EBT model Gafchromic™ film in radiotherapy
    Fiandra, Christian
    Ricardi, Umberto
    Ragona, Riccardo
    Anglesio, Silvia
    Giglioli, Francesca Romana
    Calamia, Elisa
    Lucio, Francesco
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4314 - 4319
  • [9] Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    Geleijns, J.
    Salvado Artells, M.
    Veldkamp, W. J. H.
    Lopez Tortosa, M.
    Calzado Cantera, A.
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (10) : 2334 - 2340
  • [10] Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner
    Geleijns, J.
    Artells, M. Salvado
    Bruin, P. Wde
    Matter, R.
    Muramatsu, Y.
    McNitt-Gray, M. F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10) : 3141 - 3159