Accurate virus quantitation using a Scanning Transmission Electron Microscopy (STEM) detector in a scanning electron microscope

被引:20
作者
Blancett, Candace D. [1 ]
Fetterer, David P. [2 ]
Koistinen, Keith A. [1 ,6 ]
Morazzani, Elaine M. [3 ,5 ]
Monninger, Mitchell K. [1 ]
Piper, Ashley E. [3 ]
Kuehl, Kathleen A. [1 ]
Kearney, Brian J. [4 ]
Norris, Sarah L. [2 ]
Rossi, Cynthia A. [4 ]
Glass, Pamela J. [3 ]
Sun, Mei G. [1 ]
机构
[1] US Army, Med Res Inst Infect Dis USAMRIID, Pathol Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[2] US Army, Med Res Inst Infect Dis USAMRIID, Biostat Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[3] US Army, Med Res Inst Infect Dis USAMRIID, Virol Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[4] US Army, Med Res Inst Infect Dis USAMRIID, Diagnost Syst Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[5] Gen Dynam Informat Technol, 321 Ballenger Ctr Dr, Ft Detrick, MD 21702 USA
[6] US Army, Publ Hlth Ctr, Toxicol Directorate, 5158 Blackhawk Rd, Aberdeen Proving Ground, MD 21010 USA
关键词
Scanning Transmission Electron Microscopy; Detector; Virus quantitation; EQUINE-ENCEPHALITIS-VIRUS; TO-PFU RATIO; PARTICLES; ENUMERATION; RETROVIRUS; ASSAY;
D O I
10.1016/j.jviromet.2017.06.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for accurate quantitation of virus particles has long been sought, but a perfect method still eludes the scientific community. Electron Microscopy (EM) quantitation is a valuable technique because it provides direct morphology information and counts of all viral particles, whether or not they are infectious. In the past, EM negative stain quantitation methods have been cited as inaccurate, non-reproducible, and with detection limits that were too high to be useful. To improve accuracy and reproducibility, we have developed a method termed Scanning Transmission Electron Microscopy - Virus Quantitation (STEM-VQ), which simplifies sample preparation and uses a high throughput STEM detector in a Scanning Electron Microscope (SEM) coupled with commercially available software. In this paper, we demonstrate STEM-VQ with an alphavirus stock preparation to present the method's accuracy and reproducibility, including a comparison of STEM-VQ to viral plaque assay and the ViroCyt Virus Counter.
引用
收藏
页码:136 / 144
页数:9
相关论文
共 50 条
  • [41] An Automated Scanning Transmission Electron Microscope Guided by Sparse Data Analytics
    Olszta, Matthew
    Hopkins, Derek
    Fiedler, Kevin R.
    Oostrom, Marjolein
    Akers, Sarah
    Spurgeon, Steven R.
    MICROSCOPY AND MICROANALYSIS, 2022, 28 (05) : 1611 - 1621
  • [42] Scanning Transmission Electron Microscopy Moiré sampling Geometrical Phase Analysis (STEM Moiré GPA)
    Pofelski A.
    Advances in Imaging and Electron Physics, 2021, 219 : 79 - 131
  • [43] Four-Dimensional Scanning Transmission Electron Microscopy (4D-STEM): From Scanning Nanodiffraction to Ptychography and Beyond
    Ophus, Colin
    MICROSCOPY AND MICROANALYSIS, 2019, 25 (03) : 563 - 582
  • [44] Backscattered electron imaging and scanning transmission electron microscopy imaging of multi-layers
    Merli, PG
    Morandi, V
    Corticelli, F
    ULTRAMICROSCOPY, 2003, 94 (02) : 89 - 98
  • [45] Scattering angle dependence of temperature susceptivity of electron scattering in scanning transmission electron microscopy
    Zhu, Menglin
    Hwang, Jinwoo
    ULTRAMICROSCOPY, 2022, 232
  • [47] Fast determination of sample thickness through scanning moire fringes in scanning transmission electron microscopy
    Nan, Pengfei
    Liang, Zhiyao
    Zhang, Yue
    Liu, Yangrui
    Song, Dongsheng
    Ge, Binghui
    MICRON, 2022, 155
  • [48] Subcellular localisation and identification of single atoms using quantitative scanning transmission electron microscopy
    Sheader, A. A.
    Vizcay-Barrena, G.
    Fleck, R. A.
    Flatters, S. J. L.
    Nellist, P. D.
    JOURNAL OF MICROSCOPY, 2025,
  • [49] Development of Parallel Image Detection System Using Annular Pupils for Scanning Transmission Electron Microscope
    Matsutani, Takaomi
    Taya, Masaki
    Tanaka, Takeo
    Kimura, Yoshihide
    Takai, Yoshizo
    Kawasaki, Tadahiro
    Ichihashi, Mikio
    Ikuta, Takashi
    NEW TREND IN APPLIED PLASMA SCIENCE AND TECHNOLOGY, 2010, 1282 : 111 - +
  • [50] The spatial resolution of imaging using core-loss spectroscopy in the scanning transmission electron microscope
    Cosgriff, EC
    Oxley, MP
    Allen, LJ
    Pennycook, SJ
    ULTRAMICROSCOPY, 2005, 102 (04) : 317 - 326