Accurate virus quantitation using a Scanning Transmission Electron Microscopy (STEM) detector in a scanning electron microscope

被引:20
|
作者
Blancett, Candace D. [1 ]
Fetterer, David P. [2 ]
Koistinen, Keith A. [1 ,6 ]
Morazzani, Elaine M. [3 ,5 ]
Monninger, Mitchell K. [1 ]
Piper, Ashley E. [3 ]
Kuehl, Kathleen A. [1 ]
Kearney, Brian J. [4 ]
Norris, Sarah L. [2 ]
Rossi, Cynthia A. [4 ]
Glass, Pamela J. [3 ]
Sun, Mei G. [1 ]
机构
[1] US Army, Med Res Inst Infect Dis USAMRIID, Pathol Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[2] US Army, Med Res Inst Infect Dis USAMRIID, Biostat Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[3] US Army, Med Res Inst Infect Dis USAMRIID, Virol Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[4] US Army, Med Res Inst Infect Dis USAMRIID, Diagnost Syst Div, 1425 Porter St, Ft Detrick, MD 21702 USA
[5] Gen Dynam Informat Technol, 321 Ballenger Ctr Dr, Ft Detrick, MD 21702 USA
[6] US Army, Publ Hlth Ctr, Toxicol Directorate, 5158 Blackhawk Rd, Aberdeen Proving Ground, MD 21010 USA
关键词
Scanning Transmission Electron Microscopy; Detector; Virus quantitation; EQUINE-ENCEPHALITIS-VIRUS; TO-PFU RATIO; PARTICLES; ENUMERATION; RETROVIRUS; ASSAY;
D O I
10.1016/j.jviromet.2017.06.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for accurate quantitation of virus particles has long been sought, but a perfect method still eludes the scientific community. Electron Microscopy (EM) quantitation is a valuable technique because it provides direct morphology information and counts of all viral particles, whether or not they are infectious. In the past, EM negative stain quantitation methods have been cited as inaccurate, non-reproducible, and with detection limits that were too high to be useful. To improve accuracy and reproducibility, we have developed a method termed Scanning Transmission Electron Microscopy - Virus Quantitation (STEM-VQ), which simplifies sample preparation and uses a high throughput STEM detector in a Scanning Electron Microscope (SEM) coupled with commercially available software. In this paper, we demonstrate STEM-VQ with an alphavirus stock preparation to present the method's accuracy and reproducibility, including a comparison of STEM-VQ to viral plaque assay and the ViroCyt Virus Counter.
引用
收藏
页码:136 / 144
页数:9
相关论文
共 50 条
  • [1] On the Progress of Scanning Transmission Electron Microscopy (STEM) Imaging in a Scanning Electron Microscope
    Sun, Cheng
    Mueller, Erich
    Meffert, Matthias
    Gerthsen, Dagmar
    MICROSCOPY AND MICROANALYSIS, 2018, 24 (02) : 99 - 106
  • [2] Analysis of crystal defects by scanning transmission electron microscopy (STEM) in a modern scanning electron microscope
    Sun, Cheng
    Mueller, Erich
    Meffert, Matthias
    Gerthsen, Dagmar
    ADVANCED STRUCTURAL AND CHEMICAL IMAGING, 2019, 5
  • [3] Electron Tomography of HEK293T Cells Using Scanning Electron Microscope-Based Scanning Transmission Electron Microscopy
    You, Yun-Wen
    Chang, Hsun-Yun
    Liao, Hua-Yang
    Kao, Wei-Lun
    Yen, Guo-Ji
    Chang, Chi-Jen
    Tsai, Meng-Hung
    Shyue, Jing-Jong
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (05) : 1037 - 1042
  • [4] A comparison of energy dispersive spectroscopy in transmission scanning electron microscopy with scanning transmission electron microscopy
    Carter, Jennifer L. W.
    Uz, Tugce Karakulak
    Ibrahim, Buhari
    Pigott, Jeffrey S.
    Gordon, Jerard, V
    ULTRAMICROSCOPY, 2025, 270
  • [5] Simultaneous secondary electron microscopy in the scanning transmission electron microscope with applications for in situ studies
    San Gabriel, Mia L.
    Qiu, Chenyue
    Yu, Dian
    Yaguchi, Toshie
    Howe, Jane Y.
    MICROSCOPY, 2024, 73 (02) : 169 - 183
  • [6] Accurate Nanoscale Crystallography in Real-Space Using Scanning Transmission Electron Microscopy
    Dycus, J. Houston
    Harris, Joshua S.
    Sang, Xiahan
    Fancher, Chris M.
    Findlay, Scott D.
    Oni, Adedapo A.
    Chan, Tsung-ta E.
    Koch, Carl C.
    Jones, Jacob L.
    Allen, Leslie J.
    Irving, Douglas L.
    LeBeau, James M.
    MICROSCOPY AND MICROANALYSIS, 2015, 21 (04) : 946 - 952
  • [7] COMPRESSIVE SCANNING TRANSMISSION ELECTRON MICROSCOPY
    Nicholls, D.
    Robinson, A.
    Wells, J.
    Moshtaghpour, A.
    Bahri, M.
    Kirkland, A.
    Browning, N.
    2022 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2022, : 1586 - 1590
  • [8] Imaging of semiconducting polymer blend systems using environmental scanning electron microscopy and environmental scanning transmission electron microscopy
    Williams, SJ
    Morrison, DE
    Thiel, BL
    Donald, AM
    SCANNING, 2005, 27 (04) : 190 - 198
  • [9] An Inexpensive Approach for Bright- Field and Dark- Field Imaging by Scanning Transmission Electron Microscopy in Scanning Electron Microscopy
    Patel, Binay
    Watanabe, Masashi
    MICROSCOPY AND MICROANALYSIS, 2014, 20 (01) : 124 - 132
  • [10] New area detector for atomic-resolution scanning transmission electron microscopy
    Shibata, Naoya
    Kohno, Yuji
    Findlay, Scott D.
    Sawada, Hidetaka
    Kondo, Yukihito
    Ikuhara, Yuichi
    JOURNAL OF ELECTRON MICROSCOPY, 2010, 59 (06): : 473 - 479