Stress-controlled viscoelastic tensile response of bovine cornea

被引:112
作者
Boyce, B. L.
Jones, R. E.
Nguyen, T. D.
Grazier, J. M.
机构
[1] Sandia Natl Labs, Microsyst Mat Dept, Albuquerque, NM 87123 USA
[2] Sandia Natl Labs, Dept Mat & Mech, Livermore, CA 94551 USA
关键词
bovine cornea; tension; mechanical behavior; viscoelasticity;
D O I
10.1016/j.jbiomech.2006.12.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The viscoelastic response of bovine corneas was characterized using in vilro load-controlled uniaxial tension experiments. Specifically, two types of tests were employed: cycled ramp tests over a range of loading rates and creep tests over a range of hold stresses. Multiple replicates of each were used to quantify natural variability as well as mean trends. A preconditioning protocol was used to obtain a unique reference state before testing and to overcome the effects of non-physiological loading. A quasi-linear viscoelastic model incorporating a representation of the microstructure of the cornea was compared to the experimental results. For low stresses and moderate durations this model compares favorably, but overall the material displays non-linearities that cannot be represented within the quasi-linear framework. Published by Elsevier Ltd.
引用
收藏
页码:2367 / 2376
页数:10
相关论文
共 36 条
  • [1] BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS
    ANDREASSEN, TT
    SIMONSEN, AH
    OXLUND, H
    [J]. EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) : 435 - 441
  • [2] Lamellar orientation in human cornea in relation to mechanical properties
    Boote, C
    Dennis, S
    Huang, YF
    Quantock, AJ
    Meek, KM
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2005, 149 (01) : 1 - 6
  • [3] Collagen fibrils appear more closely packed in the prepupillary cornea: Optical and biomechanical implications
    Boote, C
    Dennis, S
    Newton, RH
    Puri, H
    Meek, KM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (07) : 2941 - 2948
  • [4] Constitutive laws for biomechanical modeling of refractive surgery
    Bryant, MR
    McDonnell, PJ
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (04): : 473 - 481
  • [5] Stress relaxation preconditioning of porcine aortic valves
    Carew, EO
    Garg, A
    Barber, JE
    Vesely, I
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (04) : 563 - 572
  • [6] COGAN D G, 1951, Trans Am Acad Ophthalmol Otolaryngol, V55, P329
  • [7] The effect of strain rate on the viscoelastic response of aortic valve tissue: A direct-fit approach
    Doehring, TC
    Carew, EO
    Vesely, I
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (02) : 223 - 232
  • [8] PARAMETER-ESTIMATION USING THE QUASI-LINEAR VISCOELASTIC MODEL PROPOSED BY FUNG
    DORTMANS, LJMG
    SAUREN, AAHJ
    ROUSSEAU, EPM
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (03): : 198 - 203
  • [9] Comparative study of corneal strip extensometry and inflation tests
    Elsheikh, A
    Anderson, K
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2005, 2 (03) : 177 - 185
  • [10] Fung Y. C., 2013, BIOMECHANICS MECH PR