Convenient test using a combination of chelating agents for detection of metallo-β-lactamases in the clinical laboratory

被引:31
作者
Kim, Soo-Young [1 ]
Hong, Seong Geun [1 ]
Moland, Ellen S. [1 ]
Thomson, Kenneth S. [1 ]
机构
[1] Creighton Univ, Sch Med, Dept Med Microbiol & Immunol, Ctr Res Anti Infect & Biotechnol, Omaha, NE 68178 USA
关键词
D O I
10.1128/JCM.02486-06
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Although transmissible metallo-beta-lactamases (MBLs) are a serious threat to P-lactam antibiotic therapy, the CLSI currently does not recommend testing methods for the detection of MBI.S. The aim of this study was to evaluate the capability of double-disk tests (DDTs) by using disks containing a combination of the chelators 2-mercaptopropionic acid (MPA) and Tris-EDTA (TE) to detect MBLs. Sixteen isolates (4 Acinetobacter baumannii isolates, 6 Pseudomonas aeruginosa isolates, 1 Serratia marcescens isolate, I Aeromonas hydrophila isolate, I Aeromonas veronii isolate, 2 Chryseobacterium meningosepticum isolates, and I Stenotrophomonas maltophilia isolate) producing IMP-1, IMP-1-like, IMP-18, GIM-1, SPM-1, VIM-2, VIM-2-like, and chromosomal MBLs and 20 isolates (7 Klebsiella pneumoniae isolates, 3 Escherichia coli isolates, 5 Enterobacter cloacae isolates, 2 S. marcescens isolates, I Proteus mirabilis isolate, and 2 A. baumannii isolates) producing non-MBL carbapenemases, AmpC beta-lactamases, and extended-spectrum beta-lactamases were tested. The DDT method was evaluated by using four types of chelator disks (TE, high-strength TE, MPA, and TE plus 20 mu l of MPA [at various concentrations]) and the beta-lactams imipenem (IPM), meropenent (MEM), ertapenem (ERT), and ceftazidime (CAZ). DDTs with IPM and a TE disk supplemented with 1:320 MPA detected all MBLs and yielded no false-positive results. Some, but not all, MBL producers were detected in IPM-based tests involving the single chelator TE or MPA alone or by ERT- or CAZ-based tests. IPM-based tests with MPA concentrations other than 1:320 and all MEM-based tests had suboptimal sensitivities or specificities. DDT with IPM and a TE disk supplemented with 20 mu l of 1:320 MPA appears to be convenient for the detection of MBLs in the clinical laboratory.
引用
收藏
页码:2798 / 2801
页数:4
相关论文
共 8 条
[1]  
Arakawa Y, 2000, J CLIN MICROBIOL, V38, P40
[2]   Evaluation of the Hodge test and the imipenem-EDTA double-disk synergy test for differentiating metallo-β-lactamase-producing isolates of Pseudomonas spp. and Acinetobacter spp. [J].
Lee, K ;
Lim, YS ;
Yong, D ;
Yum, JH ;
Chong, Y .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (10) :4623-4629
[3]   Modified Hodge and EDTA-disk synergy tests to screen metallo-β-lactamase-producing strains of Pseudomonas and Acinetobacter species [J].
Lee, K ;
Chong, Y ;
Shin, HB ;
Kim, YA ;
Yong, D ;
Yum, JH .
CLINICAL MICROBIOLOGY AND INFECTION, 2001, 7 (02) :88-91
[4]   Emerging carbapenemases in Gram-negative aerobes [J].
Nordmann, P ;
Poirel, L .
CLINICAL MICROBIOLOGY AND INFECTION, 2002, 8 (06) :321-331
[5]   Use of Etest MBL strips for the detection of carbapenemases in Acinetobacter baumannii [J].
Segal, H ;
Elisha, BG .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2005, 56 (03) :598-598
[6]   Evaluation of a new etest for detecting metallo-β-lactamases in routine clinical testing [J].
Walsh, TR ;
Bolmström, A ;
Qwärnström, A ;
Gales, A .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (08) :2755-2759
[7]   Metallo-β-lactamases:: the quiet before the storm? [J].
Walsh, TR ;
Toleman, MA ;
Poirel, L ;
Nordmann, P .
CLINICAL MICROBIOLOGY REVIEWS, 2005, 18 (02) :306-+
[8]   Imipenem-EDTA disk method for differentiation of metallo-β-lactamase-producing clinical isolates of Pseudomonas spp. and Acinetobacter spp. [J].
Yong, DE ;
Lee, K ;
Yum, JH ;
Shin, HB ;
Rossolini, GM ;
Chong, YS .