Limitations of current practices in detection of bacterially contaminated blood products associated with suspected septic transfusion reactions

被引:5
作者
Martin, Isabella W. [1 ]
Cohn, Claudia S. [2 ]
Delaney, Meghan [3 ,4 ]
Fontaine, Magali J. [5 ]
Shih, Andrew W. [6 ,7 ]
Dunbar, Nancy M. [1 ]
机构
[1] Dartmouth Hitchcock Med Ctr, Dept Pathol & Lab Med, Lebanon, NH 03766 USA
[2] Univ Minnesota, Dept Lab Med & Pathol, Minneapolis, MN 55455 USA
[3] Childrens Natl Hosp, Dept Pathol & Lab Med, Washington, DC USA
[4] Univ Washington, Dept Lab Med, Seattle, WA 98195 USA
[5] Univ Maryland, Sch Med, Dept Pathol, Baltimore, MD 21201 USA
[6] Univ British Columbia, Dept Pathol & Lab Med, Vancouver, BC, Canada
[7] Vancouver Coastal Hlth Author, Vancouver, BC, Canada
关键词
bacterial contamination; residual component cultures; septic transfusion reactions;
D O I
10.1111/trf.16545
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In the setting of suspected septic transfusion reactions, bacterial culture of both the transfused patient and the residual blood component is recommended. Primary bacterial contamination can occur at the time of component collection. Clinically insignificant "secondary contamination" can occur during post-transfusion component discard, retrieval for culture, or manipulation of the bag at the time of culture sampling. Study design and methods This retrospective, multi-center study analyzes positive residual component culture results and companion patient blood cultures from 15 hospitals, 1 blood center, and all cultured transfusion reactions within the province of Quebec, Canada, over a 5-year period. Imputability was assigned as "definite" (concordant growth), "possible" (discordant growth or lack of growth in patient culture), or "unable to assess" (patient not cultured). Results There were 373 positive component cultures from 360 unique transfusion reactions, with 276 (76.7%) companion patient blood cultures performed, of which 10 (2.8%) yielded the pathogen detected in the positive component. Of these 10 definite pathogens, 7 (2 Staphylococcus aureus, 3 other staphylococci, and 1 Streptococcus pyogenes and 1 Bacillus sp.) were associated with platelet and 3 (Aeromonas veronii, Staphylococcus epidermidis, and Enterococcus faecalis) with RBC transfusions. RBC and plasma components comprised 70% of positive component cultures. Discussion The process of performing residual component culture is vulnerable to secondary contamination. The significance of microorganisms recovered from component culture cannot be interpreted in isolation. In the context of low prevalence of primary contamination of blood components, the positive predictive value of a positive component culture result is very low.
引用
收藏
页码:2414 / 2420
页数:7
相关论文
共 19 条
[1]   Economic health care costs of blood culture contamination: A systematic review [J].
Dempsey, Casey ;
Skoglund, Erik ;
Muldrew, Kenneth L. ;
Garey, Kevin W. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2019, 47 (08) :963-967
[2]   A Comprehensive Update on the Problem of Blood Culture Contamination and a Discussion of Methods for Addressing the Problem [J].
Doern, Gary V. ;
Carroll, Karen C. ;
Diekema, Daniel J. ;
Garey, Kevin W. ;
Rupp, Mark E. ;
Weinstein, Melvin P. ;
Sexton, Daniel J. .
CLINICAL MICROBIOLOGY REVIEWS, 2020, 33 (01)
[3]   A suspected septic transfusion reaction associated with posttransfusion contamination of a platelet pool by vancomycin-resistant Enterococcus faecium [J].
Drews, Steven J. ;
Lesley, Peter ;
Detsky, Michael E. ;
Distefano, Lanis ;
Ilagan, Cesario ;
Mehta, Sangeeta ;
McGeer, Allison ;
Shehata, Nadine ;
Skeate, Robert ;
Ramirez-Arcos, Sandra .
TRANSFUSION, 2020, 60 (02) :430-435
[4]   Transfusion-Transmitted Infections Reported to the National Healthcare Safety Network Hemovigilance Module [J].
Haass, Kathryn A. ;
Sapiano, Mathew R. P. ;
Savinkina, Alexandra ;
Kuehnert, Matthew J. ;
Basavaraju, Sridhar V. .
TRANSFUSION MEDICINE REVIEWS, 2019, 33 (02) :84-91
[5]   Detection of septic transfusion reactions to platelet transfusions by active and passive surveillance [J].
Hong, Hong ;
Xiao, Wenbin ;
Lazarus, Hillard M. ;
Good, Caryn E. ;
Maitta, Robert W. ;
Jacobs, Michael R. .
BLOOD, 2016, 127 (04) :496-502
[6]   Relationship between bacterial load, species virulence, and transfusion reaction with transfusion of bacterially contaminated platelets [J].
Jacobs, Michael R. ;
Good, Caryn E. ;
Lazarus, Hillard M. ;
Yomtovian, Roslyn A. .
CLINICAL INFECTIOUS DISEASES, 2008, 46 (08) :1214-1220
[7]   Bacterial contamination and septic transfusion reaction rates associated with platelet components before and after introduction of primary culture: experience at a US Academic Medical Center 1991 through 2017 [J].
Kundrapu, Sirisha ;
Srivastava, Swati ;
Good, Caryn E. ;
Lazarus, Hillard M. ;
Maitta, Robert W. ;
Jacobs, Michael R. .
TRANSFUSION, 2020, 60 (05) :974-985
[8]  
Markowitz, 2014, AABB ASS B 14 04 CLI
[9]   A Fatal Case of Septic Shock Secondary to Acinetobacter Bacteremia Acquired from a Platelet Transfusion [J].
Nevala-Plagemann, C. ;
Powers, P. ;
Mir-Kasimov, M. ;
Rose, R. .
CASE REPORTS IN MEDICINE, 2019, 2019
[10]  
Schlueter, 2016, CLIN MICROBIOLOGY PR