Initial stability of a new cementless fixation method of a tibial component with polyaxial locking screws: a biomechanical in vitro examination

被引:5
作者
Benzing, Christian [1 ]
Skwara, Adrian [1 ,2 ]
Figiel, Jens [3 ]
Paletta, Juergen [1 ]
机构
[1] Univ Hosp Marburg, Ctr Orthopaed & Trauma Surg, Baldingerstr, D-35043 Marburg, Germany
[2] Grp Practice Borken, Duesberg Str 1, D-46325 Borken, Germany
[3] Univ Marburg, Dept Diagnost Radiol, Baldingerstr, D-35043 Marburg, Germany
关键词
Cementless TKR; Polyaxial locking screws; Aseptic loosening; Initial stability; TOTAL KNEE ARTHROPLASTY; DISTAL FEMUR FRACTURES; FOLLOW-UP; INTERNAL-FIXATION; FEMORAL FRACTURES; PLATE FIXATION; RANDOMIZED RSA; MECHANICAL STABILITY; ACTIVE PATIENTS; HYDROXYAPATITE;
D O I
10.1007/s00402-016-2517-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cementless fixation of the tibial component is critical as reduced initial stability leads to implant failure. In this experimental in vitro study, a new fixation method of the tibial component using polyaxial locking screws is evaluated using Roentgen stereophotogrammetric analysis (RSA). A special prototype of a tibial component with four polyaxial locking screws was tested on 10 fresh-frozen human tibia specimens. The components were tested with an axial load of 2000 N for 10,000 cycles. Radiographs in two views were performed before loading, after 1000 and after 10,000 cycles, respectively. Besides rotation and translation along the x-, y-, and z-axes, endpoints for RSA were maximum subsidence (MaxSub), maximum lift off (MaxLiftOff) and maximum total point motion (MTPM). MaxSub increased from -0.5 mm (SD = 0.2) after 1000 cycles to -0.9 mm (SD = 1.1). MaxLiftOff was 0.1 mm after 1000 cycles and did not increase after 10,000 cycles. The MTPM was 0.7 mm (SD = 0.3) after 1000 cycles and 1.1 mm (SD = 1.1) after 10,000 cycles. Two out of nine implants showed an MTPM aeyen 1.0 mm after 10,000 cycles. Polyaxial locking screws can potentially improve the initial stability of tibial components. The results of this study indicate that the use of such screws in total knee arthroplasty may be of interest in the future. Further experimental and clinical investigation is needed.
引用
收藏
页码:1309 / 1316
页数:8
相关论文
共 63 条
  • [1] Fixation of the tibial component using CMW-1 or Palacos bone cement with gentamicin -: Similar outcome in a randomized radiostereometric study of 51 total knee arthroplasties
    Adalberth, G
    Nilsson, KG
    Kärrholm, J
    Hassander, H
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 2002, 73 (05): : 531 - 538
  • [2] Fixation of a hydroxyapatite-tricalcium phosphate-coated cementless knee prosthesis - Clinical and radiographic evaluation seven years after surgery
    Akizuki, S
    Takizawa, T
    Horiuchi, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (08): : 1123 - 1127
  • [3] Polyaxial versus uniaxial volar locking plate for distal radial fractures
    Al-Mouazzen, Louay
    Chou, Daud Tai Shan
    Kyriakopoulos, Georgios
    Hambidge, John
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 9 - 12
  • [4] PROXIMALLY CEMENTED VERSUS UNCEMENTED FREEMAN-SAMUELSON KNEE ARTHROPLASTY - A PROSPECTIVE RANDOMIZED STUDY
    ALBREKTSSON, BEJ
    CARLSSON, LV
    FREEMAN, MAR
    HERBERTS, P
    RYD, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02): : 233 - 238
  • [5] Berger RA, 2001, CLIN ORTHOP RELAT R, P196
  • [6] Tibial plateau fractures: Internal fixation with locking plates and the MIPO technique
    Biggi, F.
    Di Fabio, S.
    D'Antimo, C.
    Trevisani, S.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (11): : 1178 - 1182
  • [7] Cemented tibial component fixation performs better than cementless fixation -: A randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years
    Carlsson, Å
    Björkman, A
    Besjakov, J
    Önsten, I
    [J]. ACTA ORTHOPAEDICA, 2005, 76 (03) : 362 - 369
  • [8] Survival and functional results after a mean follow-up of 9 years with the Ceragy® highly congruent mobile-bearing TKA
    Cournapeau, J.
    Klouche, S.
    Bauer, T.
    Hardy, P.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (04) : 455 - 460
  • [9] Biomechanical Comparison of Polyaxial and Uniaxial Locking Plate Fixation in a Proximal Tibial Gap Model
    Cullen, Aaron B.
    Curtiss, Shane
    Lee, Mark A.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (07) : 507 - 513
  • [10] DODD CAF, 1990, CLIN ORTHOP RELAT R, P66