A Meta-Analysis and Investigation for the Source of Bias of Left Ventricular Volumes and Function by Three-Dimensional Echocardiography in Comparison With Magnetic Resonance Imaging

被引:90
|
作者
Shimada, Yuichi J. [2 ,3 ]
Shiota, Takahiro [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Noninvas Cardiol Lab, Cedars Sinai Med Ctr,Heart Inst, Los Angeles, CA 90095 USA
[2] Univ Hosp, Beth Israel Med Ctr, Dept Med, New York, NY USA
[3] Albert Einstein Coll Med, New York, NY USA
关键词
EJECTION FRACTION; RADIAL STRAIN; TIME; QUANTIFICATION; DYSSYNCHRONY; ADULTS; MASS;
D O I
10.1016/j.amjcard.2010.08.058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Determining accurate left ventricular (LV) function is clinically important. Three-dimensional echocardiography (3DE) achieves better estimation than 2-dimensional echocardiography. However, underestimation of LV volumes has often been reported without a systematic attempt to synthesize these data. This meta-analysis aimed to assess the bias of 3DE in evaluating LV volumes and ejection fraction (EF) and to investigate factors affecting that bias. Studies that compared LV volumes and/or EF between 3DE and magnetic resonance imaging were eligible. Meta-analysis of 95 studies including 3,055 subjects revealed significant underestimation of LV end-systolic volume (-4.7 ml, p < 0.0001) and end-diastolic volume (-9.9 ml, p < 0.0001), whereas measurement for EF revealed excellent accuracy (-0.13%, p = 0.41). Meta-regression analysis for factors of systematic bias in volumetry revealed that female gender and existence of cardiac disease were associated with more underestimation, whereas use of semiautomatic tracking and matrix-array transducers counteracted the underestimation. In conclusion, by meta-analysis synthesizing many small studies, we found underestimation of LV volumes and factors affecting the systematic bias by 3DE. These data provide a more detailed basis for analyzing and improving the accuracy of 3DE, an indispensable step toward further clinical application in LV assessment. (c) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:126-138)
引用
收藏
页码:126 / 138
页数:13
相关论文
共 50 条
  • [1] Accuracy of Right Ventricular Volumes and Function Determined by Three-Dimensional Echocardiography in Comparison with Magnetic Resonance Imaging: A Meta-Analysis Study
    Shimada, Yuichi J.
    Shiota, Maiko
    Siegel, Robert J.
    Shiota, Takahiro
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (09) : 943 - 953
  • [2] Analysis of Left Ventricular Volumes and Function: A Multicenter Comparison of Cardiac Magnetic Resonance Imaging, Cine Ventriculography, and Unenhanced and Contrast-Enhanced Two-Dimensional and Three-Dimensional Echocardiography
    Hoffmann, Rainer
    Barletta, Giuseppe
    von Bardeleben, Stephan
    Vanoverschelde, Jean Louis
    Kasprzak, Jaroslaw
    Greis, Christian
    Becher, Harald
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (03) : 292 - 301
  • [3] Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging
    Jenkins, Carly
    Moir, Stuart
    Chan, Jonathan
    Rakhit, Dhrubo
    Haluska, Brian
    Marwick, Thomas H.
    EUROPEAN HEART JOURNAL, 2009, 30 (01) : 98 - 106
  • [4] Sources of variation and bias in assessing left ventricular volumes and dyssynchrony using three-dimensional echocardiography
    Muraru, Denisa
    Badano, Luigi P.
    Ermacora, Davide
    Piccoli, Gianluca
    Iliceto, Sabino
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06) : 1357 - 1368
  • [5] Meta-Analysis of Accuracy of Left Ventricular Mass Measurement by Three-Dimensional Echocardiography
    Shimada, Yuichi J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (03) : 445 - 452
  • [6] Assessment of left ventricular volumes by use of one-, two-, and three-dimensional echocardiography versus magnetic resonance imaging in healthy dogs
    Meyer, Judith
    Wefstaedt, Patrick
    Dziallas, Peter
    Beyerbach, Martin
    Nolte, Ingo
    Hungerbuehler, Stephan O.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2013, 74 (09) : 1223 - 1230
  • [7] Assessment of right ventricular volumes in hypoplastic left heart syndrome by real-time three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging
    Bell, Aaron
    Rawlins, Debbie
    Bellsham-Revell, Hannah
    Miller, Owen
    Razavi, Reza
    Simpson, John
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (03) : 257 - 266
  • [8] Three-dimensional echocardiography to assess left ventricular geometry and function
    Guta, Andrada C.
    Badano, Luigi P.
    Ochoa-Jimenez, Roberto C.
    Genovese, Davide
    Previtero, Marco
    Civera, Stefania
    Ruocco, Alessandro
    Bettella, Natascia
    Parati, Gianfranco
    Muraru, Denisa
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2019, 17 (11) : 801 - 815
  • [9] Right ventricular remodelling in pulmonary arterial hypertension with three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging
    Grapsa, Julia
    O'Regan, Declan P.
    Pavlopoulos, Harry
    Durighel, Giuliana
    Dawson, David
    Nihoyannopoulos, Petros
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (01): : 64 - 73
  • [10] Three-Dimensional Echocardiography for Quantitative Analysis of Left-Ventricular Aneurysm
    Jahnke, Cosima
    Foell, Daniela
    Heinrichs, Gudrun
    Jung, Bernd
    Bley, Thorsten
    Handke, Michael
    Bode, Christophe
    Geibel, Annette
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (01): : 64 - 68