Power-Efficient Cross-Correlation Beat Detection in Electrocardiogram Analysis Using Bitstreams

被引:8
作者
Liseth, Olav E. [1 ]
Mo, Daniel [1 ]
Hjortland, Hakon A. [1 ]
Lande, Tor Sverre Bassen [1 ]
Wisland, Dag T. [1 ]
机构
[1] Univ Oslo, Dept Informat, N-0316 Oslo, Norway
关键词
Biomedical computing; bitstream operations; complementary metal-oxide semiconductor (CMOS); cross-correlation; sigma-delta modulation;
D O I
10.1109/TBCAS.2010.2079933
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we present a novel cross-correlator chip suitable for "smart" ECG electrodes. Sophisticated QRS-detection is feasible exploring multicomponent-based cross-correlation and by exploiting the simplicity offered by bitstream processing. The chip is evaluated using real ECG signals as an example application. Power-efficient running cross correlation is obtained with novel asynchronous circuit solutions consuming approximately 730 mu W while processing ECG data sampled at a rate of 250 Hz. The implemented generic cross-correlator may be explored for other pattern-matching applications in wireless sensor networks or other low-power applications.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 13 条
[1]   Efficient computation of the LF/HF ratio in heart rate variability analysis based on bitstream filtering [J].
Ho, Mel M. S. ;
Lande, Tor S. ;
Toumazou, Christopher .
2007 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE, 2007, :17-20
[2]   AN ECONOMICAL CLASS OF DIGITAL-FILTERS FOR DECIMATION AND INTERPOLATION [J].
HOGENAUER, EB .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1981, 29 (02) :155-162
[3]   Super-audio CID: An introduction [J].
Janssen, E ;
Reefman, D .
IEEE SIGNAL PROCESSING MAGAZINE, 2003, 20 (04) :83-90
[4]   The principles of software QRS detection [J].
Köhler, BU ;
Hennig, C ;
Orglmeister, R .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2002, 21 (01) :42-57
[5]   A database for evaluation of algorithms for measurement of QT and other waveform intervals in the ECG [J].
Laguna, P ;
Mark, RG ;
Goldberg, A ;
Moody, GB .
COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 :673-676
[6]  
Lande T. S., 2007, ELECT LETT, V43
[7]   Multi-component based cross correlation beat detection in electrocardiogram analysis [J].
Last, Thorsten ;
Nugent, Chris D. ;
Owens, Frank J. .
BIOMEDICAL ENGINEERING ONLINE, 2004, 3 (1)
[8]  
MALOBERTI F, 1991, P CIRC SYST INT C CH, V1, P438
[9]  
MALOBERTI F, 1992, P IEEE INT S CIRC SY, V6, P2645
[10]   BIT STREAM ADDER FOR OVERSAMPLING CODED DATA [J].
OLEARY, P ;
MALOBERTI, F .
ELECTRONICS LETTERS, 1990, 26 (20) :1708-1709