Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable Anatomy

被引:22
作者
Illuminati, Giulio [1 ]
Pacile, Maria Antonietta [1 ]
Ceccanei, Gianluca [1 ]
Ruggeri, Massimo [1 ]
La Torre, Giuseppe [2 ]
Ricco, Jean-Baptiste [3 ]
机构
[1] Univ Roma La Sapienza, Dept Surg Sci, Rome, Italy
[2] Univ Roma La Sapienza, Dept Publ Hlth & Epidemiol, Rome, Italy
[3] Univ Poitiers, Dept Clin Res, CHU Poitiers, Poitiers, France
关键词
RADIATION-EXPOSURE; CARBON-DIOXIDE; IMAGE FUSION; IMPACT; RISK; IVUS; EVAR; TOOL;
D O I
10.1016/j.avsg.2019.11.013
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography. Methods: From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media administered, procedure-related outcomes, and renal clearance expressed as the glomerular filtration rate (GFR) before and after the procedure. Secondary endpoints were operative mortality, morbidity, and arterial access complications. Results: Mean duration of fluoroscopy time was significantly lower for IVUS-assisted procedures (24 +/- 15 min vs. 40 +/- 30 min for angiography-assisted procedures, P < 0.01). Moreover, mean radiation dose (Air KERMA) was significantly lower in IVUS-assisted procedures (76m Gy [44-102] vs. 131 mGy [58-494]), P < 0.01. IVUS-assisted procedures required fewer contrast media than standard angiography-assisted procedures (60 +/- 20 mL vs. 120 +/- 40 mL, P < 0.01). The mean duration of the procedure was comparable in the two groups (120 +/- 30 min vs. 140 +/- 30 min, P = 0.07). No difference in renal clearance before and after the procedure was observed in either of the two groups (99.0 +/- 4/97.8 +/- 2 mUmin in group A and 98.0 +/- 3/ 97.6 +/- 5 mL/min in group B) (P = 0.28). The mean length of follow-up was nine months (630 months). No postoperative mortality, morbidity, or arterial access complications occurred. No type 1 endoleak was observed. Early type II endoleaks were observed in 21 patients (11%), 12 in the angiography-assisted group (11%) and nine in the IVUS-assisted group (12%). They were not associated with sac enlargement >= 5 mm diameter and therefore did not require any additional treatment. Conclusions: Compared with standard angiography-assisted EVAR, IVUS significantly reduces renal load with contrast media, fluoroscopy time, and radiation dose while preserving endograft deployment efficiency. Confirmation from a large prospective study with improved IVUS probes will be required before IVUS-assisted EVAR alone can become standard practice.
引用
收藏
页码:54 / 61
页数:8
相关论文
共 32 条
[1]   Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms [J].
Albertini, JN ;
Kalliafas, S ;
Travis, S ;
Yusuf, SW ;
Macierewicz, JA ;
Whitaker, SC ;
Elmarasy, NM ;
Hopkinson, BR .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 19 (03) :308-312
[2]   A COMPARISON STUDY OF RADIATION EXPOSURE TO PATIENTS DURING EVAR AND DYNACT IN AN ANGIOSUITE VS. AN OPERATING THEATRE [J].
Bruschi, Andrea ;
Michelagnoli, Stefano ;
Chisci, Emiliano ;
Mazzocchi, Silvia ;
Panci, Simone ;
Didona, Annamaria ;
Ghirelli, Alessandro ;
Zatelli, Giovanna .
RADIATION PROTECTION DOSIMETRY, 2015, 163 (04) :491-498
[3]  
Butler M, 2012, AM SURGEON, V78, P1029
[4]   Carbon dioxide digital subtraction angiography-assisted endovascular aortic aneurysm repair in the azotemic patient [J].
Chao, Alex ;
Major, Kevin ;
Kumar, Subramanyan Ram ;
Trujillo, Israel ;
Hood, Douglas B. ;
Rowe, Vincent L. ;
Weaver, Fred A. .
JOURNAL OF VASCULAR SURGERY, 2007, 45 (03) :451-458
[5]  
Fujitani R, 2007, J VASC SURG, V45, P458
[6]   Carbon dioxide angiography for endovascular grafting in high-risk patients with infrarenal abdominal aortic aneurysms [J].
Gahlen, J ;
Hansmann, J ;
Schumacher, H ;
Seelos, R ;
Richter, M ;
Allenberg, JR .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (03) :646-649
[7]  
Guntani Atsushi, 2012, Ann Vasc Dis, V5, P166, DOI 10.3400/avd.oa.11.00094
[8]   Impact of Hybrid Rooms with Image Fusion on Radiation Exposure during Endovascular Aortic Repair [J].
Hertault, A. ;
Maurel, B. ;
Sobocinski, J. ;
Gonzalez, T. Martin ;
Le Roux, M. ;
Azzaoui, R. ;
Midulla, M. ;
Haulon, S. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (04) :382-390
[9]   A Retrospective Study of Intravascular Ultrasound use in Patients Undergoing Endovascular Aneurysm Repair: Its Usefulness and a Description of the Procedure [J].
Hoshina, K. ;
Kato, M. ;
Miyahara, T. ;
Mikuriya, A. ;
Ohkubo, N. ;
Miyata, T. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 40 (05) :559-563
[10]   Risk of Radiation Exposure during Endovascular Aortic Repair [J].
Howells, P. ;
Eaton, R. ;
Patel, A. S. ;
Taylor, P. ;
Modarai, B. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (04) :393-397