A Monte Carlo optical code for the study of gamma cameras based on a scintillator read out by a silicon photodetector array

被引:3
作者
Fiorini, C [1 ]
机构
[1] Politecn Milan, Dipartimento Ingn Nucl, CESNEF, I-20133 Milan, Italy
关键词
D O I
10.1109/23.914469
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A Monte Carlo optical code for the optimization of scintillation gamma cameras based on a single scintillator coupled to arrays of Silicon Photodiodes (PDs) or Silicon Drift Detectors (SDDs) have been developed. The simulator allows to calculate the expected gain (e-/keV), position resolution and energy resolution of the gamma detector for different geometries and boundary conditions at the crystal interfaces. A validation of the algorithm has been carried out by comparing the results of the simulations with the corresponding experimental results obtained on existing prototypes of detectors recently developed. An example of application of the proposed code in the study of a small scintillation camera is also reported.
引用
收藏
页码:1911 / 1917
页数:7
相关论文
共 11 条
[1]   Position and energy resolution of a new gamma-ray detector based on a single CsI(Tl) scintillator coupled to a silicon drift chamber array [J].
Fiorini, C ;
Perotti, F ;
Labanti, C ;
Longoni, A ;
Rossi, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) :858-864
[2]   Gamma ray spectroscopy with CsI(Tl) scintillator coupled to silicon drift chamber [J].
Fiorini, C ;
Longoni, A ;
Perotti, F ;
Labanti, C ;
Lechner, P ;
Struder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) :2553-2560
[3]   SEMICONDUCTOR DRIFT CHAMBER - AN APPLICATION OF A NOVEL CHARGE TRANSPORT SCHEME [J].
GATTI, E ;
REHAK, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (03) :608-614
[4]   SUBOPTIMAL FILTERING OF 1/F-NOISE IN DETECTOR CHARGE MEASUREMENTS [J].
GATTI, E ;
MANFREDI, PF ;
SAMPIETRO, M ;
SPEZIALI, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (03) :467-478
[5]   LIGHT COLLECTION IN SCINTILLATION DETECTOR COMPOSITES FOR NEUTRON DETECTION [J].
KNOLL, GF ;
KNOLL, TF ;
HENDERSON, TM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :872-875
[6]   PICsIT: The high energy detection plane of the IBIS instrument onboard INTEGRAL [J].
Labanti, C ;
DiCocco, G ;
Malaguti, G ;
Mauri, A ;
Rossi, E ;
Schiavone, F ;
Traci, A .
GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 :269-279
[7]   PSPMT and photodiode designs of a small scintillation camera for imaging malignant breast tumors [J].
Levin, CS ;
Hoffman, EJ ;
Tornai, MP ;
MacDonald, LR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (04) :1513-1520
[8]   SIMULATION OF IMAGING WITH SODIUM-IODIDE CRYSTALS AND POSITION-SENSITIVE PHOTOMULTIPLIER TUBES [J].
ORDONEZ, CE ;
MINTZER, RA ;
AARSVOLD, JN ;
YASILLO, NJ ;
MATTHEWS, KL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1510-1515
[9]   High resolution CsI(Tl)/Si-PIN detector development for breast imaging [J].
Patt, BE ;
Iwanczyk, JS ;
Tull, CR ;
Wang, NW ;
Tornai, MP ;
Hoffman, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) :2126-2131
[10]  
Shao YP, 1996, IEEE T NUCL SCI, V43, P1938