Comparison of pencil-beam and fan-beam DXA systems

被引:13
作者
Henzell, S
Dhaliwal, SS
Price, RI
Gill, F
Ventouras, C
Green, C
Da Fonseca, F
Holzherr, M
Prince, R
机构
[1] Sir Charles Gairdner Hosp, Dept Endocrinol & Diabet, Nedlands, WA 6009, Australia
[2] Sir Charles Gairdner Hosp, Dept Med Technol & Phys, Perth, WA, Australia
[3] Univ Western Australia, Dept Med, Perth, WA 6009, Australia
[4] Sir Charles Gairdner Hosp, Western Australian Inst Med Res, Perth, WA, Australia
关键词
DXA; hologic; fan-beam; pencil-beam; QDR1000W; QDR4500W;
D O I
10.1385/JCD:6:3:205
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Patients attending a routine bone densitometry clinic were scanned on two different densitometers on the same day using a pencil-beam (Hologic QDR 1000W) and fan-beam (Hologic QDR4500W) machine. Subjects were scanned at the lumbar spine site and or the proximal femur. The differences in bone mineral density (BMD) between the fan-beam and pencil-beam (QDR4500W-QDR1000W) were determined for all pairs of scans. The mean difference in BMD was also calculated to see if there was a systematic bias between the machines. The mean difference in BMD was -8 mg/cm(2) and 25 mg/cm(2) at the spine and total hip, respectively. The individual differences in BMD between the two machines were examined to assess if they were significantly greater than measurement error. The percentage of scans classified as significantly different was calculated for the difference in BMD before and after adjusting for the mean difference in BMD. The percentage of individuals classified as significantly different ranged from 17.1-45.0% before adjustment, at the spine and total hip, respectively, and 16.1-22.6% after adjustment. From a clinical perspective, this degree of misclassification is probably unacceptable. These results suggest that scans obtained from a QDR4500W fan-beam system and QDR1000W pencil-beam system should not be compared, with or without adjustment for systematic bias.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 9 条
[1]   CROSS CALIBRATION OF QDR-2000 AND QDR-1000 DUAL-ENERGY X-RAY DENSITOMETERS FOR BONE-MINERAL AND SOFT-TISSUE MEASUREMENTS [J].
ABRAHAMSEN, B ;
GRAM, J ;
HANSEN, TB ;
BECKNIELSEN, H .
BONE, 1995, 16 (03) :385-390
[2]  
*BRIT STAND I, 1979, BS5497 BRIT STAND 1
[3]   CROSS-CALIBRATION OF DXA EQUIPMENT - UPGRADING FROM A HOLOGIC QDR 1000/W TO A QDR-2000 [J].
FAULKNER, KG ;
GLUER, CC ;
ESTILO, M ;
GENANT, HK .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (02) :79-84
[4]  
FINKELSTEIN JS, 1994, J BONE MINER RES, V9, P1945
[5]   Precision error of fan-beam dual X-ray absorptiometry scans at spine, hip, and forearm [J].
Henzell, S ;
Dhaliwal, S ;
Pontifex, R ;
Gill, F ;
Price, R ;
Retallack, R ;
Prince, R .
JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (04) :359-364
[6]  
*HOL INC, QDR4500 EL OP MAN
[7]  
Montgomery D.C., 1997, INTRO STAT QUALITY C
[8]  
NILAS L, 1988, BONE MINER, V3, P305
[9]   Differences between dual X-ray absorptiometry using pencil beam and fan beam modes and their determinants in vivo and in vitro [J].
Ruetsche, AG ;
Lippuner, K ;
Jaeger, P ;
Casez, JP .
JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (02) :157-166