Dermal allograft superior capsule reconstruction biomechanics and kinematics

被引:11
作者
Lobao, Mario H. [1 ]
Melvani, Roshan T. [1 ]
Abbasi, Pooyan [1 ]
Parks, Brent G. [1 ]
Murthi, Anand M. [1 ]
机构
[1] MedStar Union Mem Hosp, Shoulder & Elbow Serv, Dept Orthopaed Surg, Baltimore, MD USA
关键词
symbolscript capsule; defect; shoulder; stability; superior; HUMERAL HEAD; STABILITY; PRESSURE; TEARS; AREA;
D O I
10.1016/j.jse.2020.11.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To investigate the effect of a dermal allograft superior capsule reconstruction (SCR) on kinematics and joint pressure biomechanics immediately after simulated superior irreparable rotator cuff tear. Methods: This controlled laboratory study tested 8 fresh-frozen cadaveric shoulders using a custom test frame. Balanced loading configuration centered the humeral head on the glenoid, and unbalanced load created a force pulling the head toward the acromion. Experimental conditions included the intact rotator cuff, irreparable supraspinatus tear (ISST), and dermal allograft SCR. A digital sensor measured glenohumeral and subacromial contact pressure maps, and a microscribe measured the acromion-humeral distance. Results: Glenohumeral contact pressure of ISST was 175% (295 +/- 44 kPa; P = .018) of the intact rotator cuff value (169 +/- 10 kPa) at 0 degrees in the balanced condition and 176% (P = .048) of intact at 30 degrees. SCR decreased glenohumeral contact pressure to 110% (185 +/- 27 kPa; P = .044) of intact at 0 degrees and to 95% (P = .034) at 30 degrees. Unbalanced ISST contact pressure was 146% (365 +/- 23 kPa; P = .009) of intact (250 +/- 24 kPa) at 0 degrees and 122% (P = .045) at 60 degrees. SCR decreased contact pressures to 110% (274 +/- 21 kPa; P = .039) of intact at 0 degrees and to 89% (P = .003) at 60 degrees. ISST increased superior migration of the humeral head, decreasing the acromion-humeral distance by 3.0 +/- 0.6 mm (P = .006) in the unbalanced condition at 0 degrees. SCR increased the acromion-humeral distance to a value similar to that of the intact cuff (P = .003). SCR significantly lowered subacromial pressures in the unbalanced condition. Conclusions: In an irreparable supraspinatus tear model, the dermal allograft SCR showed competency in stabilizing the glenohumeral joint, decreasing glenohumeral and subacromial contact pressures, and increasing the acromion-humeral distance. Level of Evidence: Basic Science Study; Biomechanics (c) 2021 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:2156 / 2165
页数:10
相关论文
共 30 条
[1]   The Effect of Glenohumeral Fixation Angle on Deltoid Function During Superior Capsule Reconstruction: A Biomechanical Investigation [J].
Adams, Christopher R. ;
Comer, Brendan ;
Scheiderer, Bastian ;
Imhoff, Florian B. ;
Morikawa, Daichi ;
Kia, Cameron ;
Muench, Lukas N. ;
Baldino, Joshua B. ;
Mazzocca, Augustus D. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (02) :400-408
[2]   Establishing a new index of muscle cross-sectional area and its relationship with isometric muscle strength [J].
Akagi, Ryota ;
Kanehisa, Hiroaki ;
Kawakami, Yasuo ;
Fukunaga, Tetsuo .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2008, 22 (01) :82-87
[3]   Effect of Calibration Method on Tekscan Sensor Accuracy [J].
Brimacombe, Jill M. ;
Wilson, David R. ;
Hodgson, Antony J. ;
Ho, Karen C. T. ;
Anglin, Carolyn .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (03)
[4]   Arthroscopic Superior Capsular Reconstruction for Massive Irreparable Rotator Cuff Repair [J].
Burkhart, Stephen S. ;
Denard, Patrick J. ;
Adams, Christopher R. ;
Brady, Paul C. ;
Hartzler, Robert U. .
ARTHROSCOPY TECHNIQUES, 2016, 5 (06) :E1407-E1418
[5]   Superior Capsule Reconstruction With Subacromial Allograft Spacer: Biomechanical Cadaveric Study of Subacromial Contact Pressure and Superior Humeral Head Translation [J].
Curtis, Daniel M. ;
Lee, Cody S. ;
Qin, Charles ;
Edgington, Jonathan ;
Parekh, Amit ;
Miller, John ;
Tokish, John M. ;
Amirouche, Farid ;
Athiviraham, Aravind .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (03) :680-686
[6]  
Dimock RAC, 2019, ARCH BONE JT SURG-AB, V7, P3
[7]   Accuracy of circular contact area measurements with thin-film pressure sensors [J].
Drewmak, Elizabeth I. ;
Crisco, Joseph J. ;
Spenciner, David B. ;
Fleming, Braden C. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2569-2572
[8]   Arthroscopic Superior Capsular Reconstruction for Treatment of Massive Irreparable Rotator Cuff Tears [J].
Hirahara, Alan M. ;
Adams, Christopher R. .
ARTHROSCOPY TECHNIQUES, 2015, 4 (06) :E637-E641
[9]   The Superior Glenohumeral Joint Capsule Alone Does Not Prevent Superior Translation of the Humeral Head: An In Vitro Biomechanical Study [J].
Hu, Qingxiang ;
Ding, Zhenyu ;
Zhang, Haoyu ;
He, Yaohua .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (11) :2962-2970
[10]   Role of the superior shoulder capsule in passive stability of the glenohumeral joint [J].
Ishihara, Yoko ;
Mihata, Teruhisa ;
Tamboli, Mallika ;
Lauren Nguyen ;
Park, Kyoung Jin ;
McGarry, Michelle H. ;
Takai, Shinro ;
Lee, Thay Q. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (05) :642-648