Clinical proof of practicability for an ECG device without any conductive contact

被引:10
|
作者
Czaplik, Michael [1 ]
Eilebrecht, Benjamin [2 ]
Ntouba, Alexandre [3 ]
Walter, Marian [2 ]
Schauerte, Patrick [4 ]
Leonhardt, Steffen [2 ]
Rossaint, Rolf [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Anaesthesiol, Aachen, Germany
[2] Rhein Westfal TH Aachen, Philips Chair Med Informat Technol, Aachen, Germany
[3] Practicien Hosp Anesthesie Reanimat, Amiens 1, France
[4] Rhein Westfal TH Aachen, Dept Cardiol, Aachen, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2010年 / 55卷 / 05期
关键词
capacitively coupled electrodes; ECG; electrocardiogram; non-conductive contact; premedication department; rhythm disturbances; ELECTRODES; SYSTEM; HEART;
D O I
10.1515/BMT.2010.035
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heart rhythm disturbances are common symptoms of several heart disorders. One of the most effective screening methods is the traditional electrode-based ECG. However, this examination can be both time- and resource-consuming. Capacitive-coupling ECG (cECG) screening - working without any conductive electrical contact with the patient - might help to shorten the time required for diagnosis. In this study, we examine the practicability of employing a non-contact capacitive ECG in a clinical setting. A total of 30 volunteer patients aged over 50 years without pacemakers were included in our trial, after obtaining their written informed consent and their medical history. A cECG as well as a conventional, conductive ECG were recorded simultaneously. In addition to mathematical analysis, ECG data were manually evaluated by two clinicians blinded to the recording method and patient conditions. Data from 30 patients were collected during our study, seven of whom had experienced myocardial infarction. The obtained cECG signals showed a high correlation with the simultaneously recorded Einthoven lead II of the conventional ECG. The values for heart rate, PQ and QT time periods correlated particularly well. Significant differences were observed with regard to QRS duration. Data recorded in the supine position contained less motion artefacts and, in particular, there were fewer breathing artefacts compared to data collected from those in a sitting position. Owing to the easy and quick application of the cECG system, the feedback from the examined patients was consistently positive. In conclusion, recording cECG data in a sitting position provided sufficient quality for screening purposes. Further studies will be needed for the evaluation of cECG appropriateness in diagnosing heart disease.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 50 条
  • [41] Heart-rate agreement between ECG and a new, wireless device during early skin-to-skin contact
    Lavizzari, Anna
    Falgari, Roberta
    Pesenti, Nicola
    Colnaghi, Mariarosa
    Colombo, Lorenzo
    Zanotta, Lidia
    Sannino, Patrizio
    Plevani, Laura
    Mosca, Fabio
    ACTA PAEDIATRICA, 2021, 110 (06) : 1803 - 1809
  • [42] Asymptotic stability of viscous contact wave for the inflow problem of the heat-conductive ideal gas without viscosity
    Hou, Meichen
    Fan, Lili
    NONLINEAR ANALYSIS-REAL WORLD APPLICATIONS, 2022, 63
  • [43] Clinical and angiographic characteristics in patients with acute myocardial infarction without any cardiovascular risk factors
    Lee, K. H.
    Park, H. W.
    Cho, J. G.
    Kim, S. S.
    Jeong, M. H.
    Ahn, Y. K.
    Park, J. C.
    EUROPEAN HEART JOURNAL, 2014, 35 : 142 - 142
  • [44] CLINICAL, ELECTROENCEPHALOGRAPHIC, AND DEVELOPMENTAL STUDIES ON CHILDREN WITH THE LENNOX SYNDROME WITHOUT ANY DETECTABLE UNDERLYING DISEASES
    OZAKI, N
    TAMAMOTO, A
    HASHIMOTO, K
    KONISHI, K
    TAKAYA, K
    CHIKUSA, A
    BRAIN & DEVELOPMENT, 1986, 8 (02): : 161 - 161
  • [45] Are there any differences in clinical and biochemical variables between bipolar patients with or without lifetime psychotic symptoms?
    Esposito, C. M.
    Ceresa, A.
    Di Paolo, M.
    Surace, T.
    Moioli, L.
    Legnani, F.
    Nosari, G.
    Ciappolino, V.
    Auxilia, A. M.
    Cappellazzi, M.
    Tagliabue, I.
    Cirella, L.
    Capuzzi, E.
    Caldiroli, A.
    Dekanalis, A.
    Clerici, M.
    Buoli, M.
    EUROPEAN PSYCHIATRY, 2023, 66 : S505 - S506
  • [46] Are There Any Differences in Clinical and Biochemical Variables between Bipolar Patients with or without Lifetime Psychotic Symptoms?
    Esposito, Cecilia Maria
    Barkin, Jennifer L.
    Ceresa, Alessandro
    Nosari, Guido
    Di Paolo, Martina
    Legnani, Francesca
    Cirella, Luisa
    Surace, Teresa
    Tagliabue, Ilaria
    Capuzzi, Enrico
    Caldiroli, Alice
    Dakanalis, Antonios
    Politi, Pierluigi
    Clerici, Massimo
    Buoli, Massimiliano
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [47] Are there any differences in clinical and biochemical variables between bipolar patients with or without lifetime psychotic symptoms?
    Esposito, C. M.
    Ceresa, A.
    Di Paolo, M.
    Surace, T.
    Moioli, L.
    Legnani, F.
    Nosari, G.
    Ciappolino, V.
    Auxilia, A. M.
    Cappellazzi, M.
    Tagliabue, I.
    Cirella, L.
    Capuzzi, E.
    Caldiroli, A.
    Dekanalis, A.
    Clerici, M.
    Buoli, M.
    EUROPEAN PSYCHIATRY, 2023, 66 : S505 - S506
  • [49] A novel intrapericardial pulsatile device for individualized, biventricular circulatory support without direct blood contact
    Schueler, Stephan
    Bowles, Christopher T.
    Hinkel, Rabea
    Wohlfarth, Robert
    Schmid, Michael R.
    Wildhirt, Stephen
    Stock, Ulrich
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 166 (04): : 1119 - 1130
  • [50] RECESSIVE SEX-RELATED MENTAL-RETARDATION WITHOUT ANY SPECIFIC CLINICAL MANIFESTATIONS
    DENISOVA, LV
    BEDELBAEVA, KA
    ZHURNAL NEVROPATOLOGII I PSIKHIATRII IMENI S S KORSAKOVA, 1983, 83 (03): : 412 - 416