Clinical proof of practicability for an ECG device without any conductive contact

被引:10
|
作者
Czaplik, Michael [1 ]
Eilebrecht, Benjamin [2 ]
Ntouba, Alexandre [3 ]
Walter, Marian [2 ]
Schauerte, Patrick [4 ]
Leonhardt, Steffen [2 ]
Rossaint, Rolf [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Anaesthesiol, Aachen, Germany
[2] Rhein Westfal TH Aachen, Philips Chair Med Informat Technol, Aachen, Germany
[3] Practicien Hosp Anesthesie Reanimat, Amiens 1, France
[4] Rhein Westfal TH Aachen, Dept Cardiol, Aachen, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2010年 / 55卷 / 05期
关键词
capacitively coupled electrodes; ECG; electrocardiogram; non-conductive contact; premedication department; rhythm disturbances; ELECTRODES; SYSTEM; HEART;
D O I
10.1515/BMT.2010.035
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heart rhythm disturbances are common symptoms of several heart disorders. One of the most effective screening methods is the traditional electrode-based ECG. However, this examination can be both time- and resource-consuming. Capacitive-coupling ECG (cECG) screening - working without any conductive electrical contact with the patient - might help to shorten the time required for diagnosis. In this study, we examine the practicability of employing a non-contact capacitive ECG in a clinical setting. A total of 30 volunteer patients aged over 50 years without pacemakers were included in our trial, after obtaining their written informed consent and their medical history. A cECG as well as a conventional, conductive ECG were recorded simultaneously. In addition to mathematical analysis, ECG data were manually evaluated by two clinicians blinded to the recording method and patient conditions. Data from 30 patients were collected during our study, seven of whom had experienced myocardial infarction. The obtained cECG signals showed a high correlation with the simultaneously recorded Einthoven lead II of the conventional ECG. The values for heart rate, PQ and QT time periods correlated particularly well. Significant differences were observed with regard to QRS duration. Data recorded in the supine position contained less motion artefacts and, in particular, there were fewer breathing artefacts compared to data collected from those in a sitting position. Owing to the easy and quick application of the cECG system, the feedback from the examined patients was consistently positive. In conclusion, recording cECG data in a sitting position provided sufficient quality for screening purposes. Further studies will be needed for the evaluation of cECG appropriateness in diagnosing heart disease.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 50 条
  • [21] CLINICAL VALIDATION OF A NOVEL, SMARTPHONE-BASED 12-LEAD ECG DEVICE
    Stavrakis, Stavros
    Whyte, Seabrook
    Sample, Karlie
    Barber, Rylee
    Albert, David
    Po, Sunny S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 2034 - 2034
  • [22] Clinical Validation of a Chest-Worn Personal ECG Device for the Detection of Atrial Fibrillation
    Reddy, Satish
    Kennedy, Alan
    Vidyasagar, Kirthi
    Doggart, Peter
    Joseph, Peter
    Funston, Rebecca C.
    Bhushan, Manav
    CIRCULATION, 2023, 148
  • [23] Ovarian Actinomycosis: Presenting as Ovarian Mass Without Any History of Intra-Uterine Copper Device
    Singh, Sunita
    Batra, Ashima
    Dua, Shivani
    Duhan, Amrita
    JOURNAL OF GLOBAL INFECTIOUS DISEASES, 2012, 4 (04) : 222 - 223
  • [24] CLINICAL ASPECTS, EXPERIMENTAL PROOF OF PROTEOLYTIC ACTIVITIES IN CORNEAL PATHOLOGY (WITHOUT THERAPY)
    BROWN, SI
    ARCHIVES D OPHTALMOLOGIE, 1975, 35 (01): : 91 - 94
  • [25] Carotid artery stenting without using any embolic protective device. A single Centre experience
    Inanc, Yusuf
    Mete, Ahmet
    Giray, Semih
    Inanc, Yilmaz
    ANNALI ITALIANI DI CHIRURGIA, 2018, 89 (06) : 556 - 561
  • [26] Strategy for clinical trials evaluating QT prolongation by drugs without evident effect on ECG
    Kumagai, Yuji
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2008, 106 : 26P - 26P
  • [27] Efficient and Fast ECG Baseline Wander Reduction without Distortion of Important Clinical Information
    Hargittai, S.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 841 - 844
  • [28] Isolation of Salmonella spp from the environment of dairies without any history of clinical salmonellosis
    Peek, SF
    Hartmann, FA
    Thomas, CB
    Nordlund, KV
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2004, 225 (04): : 574 - 577
  • [29] Parkinson's Disease with and without REM Sleep Behaviour Disorder: Are There Any Clinical Differences?
    Yoritaka, Asako
    Ohizumi, Hideki
    Tanaka, Shigeki
    Hattori, Nobutaka
    EUROPEAN NEUROLOGY, 2009, 61 (03) : 164 - 170
  • [30] Furuncular myiasis: Dermoscopic features using a cross-polarized device without contact
    de Lima, Adma Silva
    Rovere, Rodrigo Kraft
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2015, 72 (01) : S6 - S7