Performance characteristics of a supplementary stack-cooling system for fuel-cell vehicles using a carbon dioxide air-conditioning unit

被引:11
作者
Kim, S. C. [2 ]
Park, J. C. [3 ]
Kim, M. S. [1 ]
机构
[1] Seoul Natl Univ, Sch Mech & Aerosp Engn, Seoul 151744, South Korea
[2] Korea Automot Technol Inst KATECH, Green Powertrain Syst R&D Ctr, Chungnam 330912, South Korea
[3] Hyundai Kia Motors, Chassis & Powertrain Engn Team 2, Hwaseong Si 445706, Gyeonggi, South Korea
关键词
Fuel-cell vehicle; Stack-cooling system; Air-conditioning unit; Carbon dioxide; Coefficient of performance (COP); CO2;
D O I
10.1007/s12239-010-0106-1
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In fuel-cell-powered vehicles, the fuel-cell system requires a thermal-management subsystem to dissipate heat released during the reaction of hydrogen with oxygen. When the stack generates power at a high rate, a large amount of heat is also generated. If cooling by the radiator is insufficient, a supplementary stack-cooling system is needed to maintain a safe operating temperature. In this study, the performance of a CO2 air-conditioning unit for stack cooling was investigated under various conditions, and the relationship between cabin cooling and stack cooling was also studied. The coefficient of performance (COP) increased from 1.9 to 2.4, with an increase in cabin-air inlet flow rate from 0 to 8 m(3)/min. When the air-conditioning unit was turned off, the cooling capacity of the stack cooler was increased; correspondingly, as the cabin-cooling capacity was increased, that of the stack cooler decreased. With an increase in ambient-air inlet temperature from 38A degrees C to 45A degrees C, the COP decreased by 24%. Additionally, both the stack-cooling capacity and cabin-cooling capacity were decreased by about 12% and 16%, respectively, due to reduced heat transfer in the gas cooler as the ambient air inlet temperature was increased. It is expected that the experimental results can serve as a resource in designing a stack-cooling system using a CO2 air-conditioning unit to enhance stack power generation and efficiency.
引用
收藏
页码:893 / 900
页数:8
相关论文
共 8 条
[1]  
Brown JS, 2002, INT J REFRIG, V25, P19
[2]   Performance evaluation of a CO2 heat pump system for fuel cell vehicles considering the heat exchanger arrangements [J].
Kim, Sung Chul ;
Kim, Min Soo ;
Hwang, In Chul ;
Lim, Tae Won .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (07) :1195-1206
[3]   Performance evaluation of a stack cooling system using CO2 air conditioner in fuel cell vehicles [J].
Kim, Sung Chul ;
Won, Jong Phil ;
Park, Yong Sun ;
Lim, Tae Won ;
Kim, Min Soo .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (01) :70-77
[4]  
OGBURN M, 2000, P SAE, V1, P3
[5]   A comparison of hydrogen, methanal and gasoline as fuels for fuel cell vehicles: implications for vehicle design and infrastructure development [J].
Ogden, JM ;
Steinbugler, MM ;
Kreutz, TG .
JOURNAL OF POWER SOURCES, 1999, 79 (02) :143-168
[6]  
PETTERSEN J, 1997, IIR IEA WORKSH CO2 T
[7]   Experimental study on automotive cooling and heating air conditioning system using CO2 as a refrigerant [J].
Tamura, T ;
Yakumaru, Y ;
Nishiwaki, F .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08) :1302-1307
[8]  
Yin J., 1998, P 3 IIR GUST LOR C N, P331