The effect of moisture and air gap on the thermal protective performance of fabric assemblies used by wildland firefighters

被引:27
作者
He, Hualing [1 ,2 ]
Yu, Zhi-Cai [2 ]
Song, Guowen [1 ]
机构
[1] Tianjin Polytech Univ, Sch Text, Tianjin, Peoples R China
[2] Eastern Liaoning Univ, Sch Chem Engn, Liaoning Key Lab Funct Text Mat, Dandong, Peoples R China
关键词
air gap; moisture content; thermal protective performance; fabric assemblies; wildland firefighters; FLAME-RESISTANT FABRICS; GARMENT DESIGN; HEAT-TRANSFER; FLASH FIRES; MANNEQUIN; EXPOSURES;
D O I
10.1080/00405000.2015.1083258
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
The thermal protection performance (TPP) provided by fabric assemblies used by wildland firefighters is greatly affected by both the moisture and the air gap trapped in multilayer fabrics. In this paper, the effect of moisture, coupled with air gap on TPP was analyzed under radiant heat exposures of 21 kW/m(2). The air gap sizes from 0 to 5.2 mm were analyzed using an air gap height regulation device; the moisture content of the multilayer fabric combinations around 0-70% were obtained by spraying distilled water to simulate varying amounts of sweat absorption. The results obtained indicate that certain air gaps entrapped in multilayer fabric system have a positive effect on TPP for both dry and wet multilayer fabric combinations. However, obvious trend changes in thermal protection were observed among dry and wet configurations when the air gap was moved to different positions. For the wet configurations, the second-degree burn time increased as the air gap moved further from the heat source, which was contrary to burn time response under dry conditions. These findings suggest that the complicated reciprocal effect of air gap and moisture on thermal protection should be both considered in analyzing the TPP of fabric assemblies.
引用
收藏
页码:1030 / 1036
页数:7
相关论文
共 19 条
[1]   Effects of moisture on the thermal protective performance of firefighter protective clothing in low-level radiant heat exposures [J].
Barker, RL ;
Guerth-Schacher, C ;
Grimes, RV ;
Hamouda, H .
TEXTILE RESEARCH JOURNAL, 2006, 76 (01) :27-31
[2]   Moisture transport and absorption in multilayer protective clothing fabrics [J].
Keiser, Corinne ;
Becker, Cordula ;
Rossi, Rene M. .
TEXTILE RESEARCH JOURNAL, 2008, 78 (07) :604-613
[3]  
Lawson Lelia K, 2004, Int J Occup Saf Ergon, V10, P227
[4]   Investigation and correlation of manikin and bench-scale fire testing of clothing systems [J].
Lee, C ;
Kim, IY ;
Wood, A .
FIRE AND MATERIALS, 2002, 26 (06) :269-278
[5]  
LEE YM, 1986, J FIRE SCI, V4, P315
[6]   Effect of relative humidity coupled with air gap on heat transfer of flame-resistant fabrics exposed to flash fires [J].
Li, Jun ;
Lu, Yehu ;
Li, Xiaohui .
TEXTILE RESEARCH JOURNAL, 2012, 82 (12) :1235-1243
[7]   Investigation of the Contribution of Garment Design to Thermal Protection. Part 2: Instrumented Female Mannequin Flash-fire Evaluation System [J].
Mah, Tannie ;
Song, Guowen .
TEXTILE RESEARCH JOURNAL, 2010, 80 (14) :1473-1487
[8]   Investigation of the Contribution of Garment Design to Thermal Protection. Part 1: Characterizing Air Gaps using Three-dimensional Body Scanning for Women's Protective Clothing [J].
Mah, Tannie ;
Song, Guowen .
TEXTILE RESEARCH JOURNAL, 2010, 80 (13) :1317-1329
[9]  
Morse H. L., 1973, AFMLTR87317 AER DIV
[10]  
Sawcyn C. M., 2003, THESIS, P1