Towards fast whole-body PET/MR: Investigation of PET image quality versus reduced PET acquisition times

被引:15
作者
Lindemann, Maike E. [1 ]
Stebner, Vanessa [2 ]
Tschischka, Alexander [3 ]
Kirchner, Julian [3 ]
Umutlu, Lale [4 ]
Quick, Harald H. [1 ,5 ]
机构
[1] Univ Duisburg Essen, Univ Hosp Essen, High Field & Hybrid MR Imaging, Essen, Germany
[2] Univ Duisburg Essen, Med Fac, Dept Nucl Med, Essen, Germany
[3] Univ Dusseldorf, Univ Hosp Dusseldorf, Dept Diagnost & Intervent Radiol, Dusseldorf, Germany
[4] Univ Duisburg Essen, Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
[5] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
EMISSION TOMOGRAPHY/MAGNETIC RESONANCE; TRACER DOSE REDUCTION; PERFORMANCE EVALUATION; ATTENUATION CORRECTION; CLINICAL-EXPERIENCE; INTEGRATED PET/MR; F-18-FDG PET/MRI; SCANNER; IMPLEMENTATION; SIMULATION;
D O I
10.1371/journal.pone.0206573
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose The trend towards faster acquisition protocols in whole-body positron emission tomography/magnetic resonance (PET/MR) arises the question of whether short PET data acquisition protocols in a whole-body multi-station context allow for reduced PET acquisition times while providing adequate PET image quality and accurate quantification parameters. The study goal is to investigate how reducing PET acquisition times affects PET image quality and quantification in whole-body PET/MR in patients with oncologic findings. Methods Fifty-one patients with different oncologic findings underwent a clinical whole-body 18F-Fluorodeoxyglucose PET/MR examination. PET data was reconstructed with 4, 3, 2, and 1 min/bed time intervals for each patient to simulate the effect of reduced PET acquisition times. The 4-minute PET reconstructions served as reference standard. All whole-body PET data sets were analyzed regarding image quality, lesion detectability, PET quantification and standardized uptake values. Results A total of 91 lesions were detected in the 4-minute PET reconstructions. The same number of congruent lesions was also noticed in the 3 and 2 minutes-per-bed (mpb) reconstructed images. A total of 2 lesions in 2 patients was not detected in the 1 minute PET data reconstructions due to poor image quality. Image noise in the blood pool increased from 22.2% (4 mpb) to 42.1% (1 mpb). Signal-to-noise ratio declined with shorter timeframes from 13.1 (4 mpb) to 9.3 (1 mpb). SUVmean and SUVmax showed no significant changes between 4 and 1 mpb reconstructed timeframes. Conclusions Reconstruction of PET data with different time intervals has shown that 2 minutes acquisition time per bed position instead of 4 minutes is sufficient to provide accurate lesion detection and adequate image quality in a clinical setting, despite the trends to lower image quality with shorter PET acquisition times. This provides latitude for potential reduction of PET acquisition times in fast PET/MR whole-body examinations.
引用
收藏
页数:15
相关论文
共 24 条
[1]   Implementation and Performance Evaluation of Simultaneous PET/MR Whole-Body Imaging with Continuous Table Motion [J].
Braun, Harald ;
Ziegler, Susanne ;
Lentschig, Markus G. ;
Quick, Harald H. .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (01) :161-168
[2]  
Delso G, 2011, J NUCL MED, V52, P1914, DOI 10.2967/jnumed.111.092726
[3]   First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses [J].
Drzezga, Alexander ;
Souvatzoglou, Michael ;
Eiber, Matthias ;
Beer, Ambros J. ;
Fuerst, Sebastian ;
Martinez-Moeller, Axel ;
Nekolla, Stephan G. ;
Ziegler, Sibylle ;
Ganter, Carl ;
Rummeny, Ernst J. ;
Schwaiger, Markus .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) :845-855
[4]   Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions [J].
Eiber, Matthias ;
Martinez-Moeller, Axel ;
Souvatzoglou, Michael ;
Holzapfel, Konstantin ;
Pickhard, Anja ;
Loeffelbein, Dennys ;
Santi, Ivan ;
Rummeny, Ernst J. ;
Ziegler, Sibylle ;
Schwaiger, Markus ;
Nekolla, Stephan G. ;
Beer, Ambros J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (09) :1691-1701
[5]  
Gatidis S, 2016, HELL J NUCL MED, V19, P15, DOI 10.1967/s002449910333
[6]  
Grueneisen J, 2016, PLOS ONE, V11, DOI [10.1371/journal.pone.0157880, DOI 10.1371/JOURNAL.PONE.0157880ECOLLECTION]
[7]   Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients [J].
Grueneisen, Johannes ;
Sawicki, Lino Morris ;
Wetter, Axel ;
Kirchner, Julian ;
Kinner, Sonja ;
Aktas, Bahriye ;
Forsting, Michael ;
Ruhlmann, Verena ;
Umutlu, Lale .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 89 :14-19
[8]   Implementation of FAST-PET/MRI for whole-body staging of female patients with recurrent pelvic malignancies: A comparison to PET/CT [J].
Grueneisen, Johannes ;
Schaarschmidt, Benedikt Michael ;
Heubner, Martin ;
Suntharalingam, Saravanabavaan ;
Milk, Ines ;
Kinner, Sonja ;
Heubner, Antonia ;
Forsting, Michael ;
Lauenstein, Thomas ;
Ruhlmann, Verena ;
Umutlu, Lale .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) :2097-2102
[9]   Patient Comfort During Positron Emission Tomography/Magnetic Resonance and Positron Emission Tomography/Computed Tomography Examinations Subjective Assessments With Visual Analog Scales [J].
Gueckel, Brigitte ;
Gatidis, Sergios ;
Enck, Paul ;
Schaefer, Juergen ;
Bisdas, Sotirios ;
Pfannenberg, Christina ;
Schwenzer, Nina .
INVESTIGATIVE RADIOLOGY, 2015, 50 (10) :726-732
[10]   Optimizing Positron Emission Tomography Image Acquisition Protocols in Integrated Positron Emission Tomography/Magnetic Resonance Imaging [J].
Hartung-Knemeyer, Verena ;
Beiderwellen, Karsten J. ;
Buchbender, Christian ;
Kuehl, Hilmar ;
Lauenstein, Thomas C. ;
Bockisch, Andreas ;
Poeppel, Thorsten D. .
INVESTIGATIVE RADIOLOGY, 2013, 48 (05) :290-294