Assaying cardiac biomarkers for toxicity testing using biosensing and cardiomyocytes derived from human embryonic stem cells

被引:41
作者
Andersson, Henrik [1 ]
Steel, Daniella [2 ]
Asp, Julia [3 ]
Dahlenborg, Kerstin [1 ]
Jonsson, Marianne [3 ]
Jeppsson, Anders [4 ]
Lindahl, Anders [3 ]
Kagedal, Bertil [5 ]
Sartipy, Peter [2 ]
Mandenius, Carl-Fredrik [1 ]
机构
[1] Linkoping Univ, Div Biotechnol IFM, S-58183 Linkoping, Sweden
[2] Cellartis AB, Gothenburg, Sweden
[3] Univ Gothenburg, Sahlgrenska Acad, Inst Biomed, Dept Clin Chem & Transfus Med, Gothenburg, Sweden
[4] Sahlgrens Univ Hosp, Dept Cardiothorac Surg, Gothenburg, Sweden
[5] Linkoping Univ, Div Clin Chem, S-58183 Linkoping, Sweden
关键词
In vitro toxicity testing; hESC-derived cardiomyocytes; Doxorubicin; Biosensors; Surface plasmon resonance. SPR; ACID-BINDING PROTEIN; ANTIBODY-ANTIGEN INTERACTIONS; ACUTE MYOCARDIAL-INFARCTION; SURFACE-PLASMON RESONANCE; MULTICENTER EVALUATION; INDUCED CARDIOTOXICITY; KINETIC-ANALYSIS; RECOMMENDATIONS; IMMUNOSENSOR; PERFORMANCE;
D O I
10.1016/j.jbiotec.2010.06.023
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Human embryonic stem cell (hESC) derived cardiomyocytes are in the present study being used for testing drug-induced cardiotoxicity in a biosensor set-up. The design of an in vitro testing alternative provides a novel opportunity to surpass previous methods based on rodent cells or cell lines due to its significantly higher toxicological relevance. In this report we demonstrate how hESC-derived cardiomyocytes release detectable levels of two clinically decisive cardiac biomarkers, cardiac troponin T and fatty acid binding protein 3, when the cardiac cells are exposed to the well-known cardioactive drug compound. doxorubicin. The release is monitored by the immuno-biosensor technique surface plasmon resonance, particularly appropriate due to its capacity for parallel and high-throughput analysis in complex media. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 30 条
[1]   Cardiovascular toxicity caused by cancer treatment: strategies for early detection [J].
Altena, Renske ;
Perik, Patrick J. ;
van Veldhuisen, Dirk J. ;
de Vries, Elisabeth G. E. ;
Gietema, Jourik A. .
LANCET ONCOLOGY, 2009, 10 (04) :391-399
[2]   Human embryonic stem cells:: Current technologies and emerging industrial applications [J].
Ameen, Caroline ;
Strehl, Raimund ;
Bjorquist, Petter ;
Lindahl, Anders ;
Hyllner, Johan ;
Sartipy, Peter .
CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2008, 65 (01) :54-80
[3]  
ANDERSSON H, ANAL BIOANA IN PRESS
[4]   In Vitro Electrophysiological Drug Testing Using Human Embryonic Stem Cell Derived Cardiomyocytes [J].
Caspi, Oren ;
Itzhaki, Ilanit ;
Kehat, Izhak ;
Gepstein, Amira ;
Arbel, Gil ;
Huber, Irit ;
Satin, Jonathan ;
Gepstein, Lior .
STEM CELLS AND DEVELOPMENT, 2009, 18 (01) :161-172
[5]   Rapid analysis of fatty acid-binding proteins with immunosensors and immunotests for early monitoring of tissue injury [J].
Chan, CPY ;
Wan, TSM ;
Watkins, KL ;
Pelsers, MMAL ;
Van der Voort, DL ;
Tang, FPW ;
Lam, KHK ;
Mill, J ;
Yuan, Y ;
Lehmann, M ;
Hempel, A ;
Sanderson, JE ;
Glatz, JFC ;
Renneberg, R .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2566-2580
[6]   Kinetic analysis of interactions between bispecific monoclonal antibodies and immobilized antigens using a resonant mirror biosensor [J].
Dmitriev, DA ;
Massino, YS ;
Segal, OL .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 280 (1-2) :183-202
[7]   Biochemical Markers for Prediction of Chemotherapy-Induced Cardiotoxicity Systematic Review of the Literature and Recommendations for Use [J].
Dolci, Alberto ;
Dominici, Roberto ;
Cardinale, Daniela ;
Sandri, Maria T. ;
Panteghini, Mauro .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (05) :688-695
[8]   Evaluation of the analytical performance of the Boehringer Mannheim Elecsys® 2010 immunoanalyzer [J].
Forest, JC ;
Massé, J ;
Lane, A .
CLINICAL BIOCHEMISTRY, 1998, 31 (02) :81-88
[9]   Human embryonic stem cells develop into multiple types of cardiac myocytes - Action potential characterization [J].
He, JQ ;
Ma, Y ;
Lee, Y ;
Thomson, JA ;
Kamp, TJ .
CIRCULATION RESEARCH, 2003, 93 (01) :32-39
[10]   KINETIC-ANALYSIS OF MONOCLONAL ANTIBODY-ANTIGEN INTERACTIONS WITH A NEW BIOSENSOR BASED ANALYTICAL SYSTEM [J].
KARLSSON, R ;
MICHAELSSON, A ;
MATTSSON, L .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 145 (1-2) :229-240