A randomized trial of non-fasting vs. fasting for cardiac implantable electronic device procedures (Fast-CIED Study)

被引:8
|
作者
Bode, Kerstin [1 ,2 ]
Gerhards, Matthias [1 ]
Doering, Michael [1 ]
Lucas, Johannes [1 ]
Tijssen, Jan [3 ]
Dagres, Nikolaos [1 ]
Hilbert, Sebastian [1 ]
Richter, Sergio [1 ]
Nedios, Sotirios [1 ]
Lurz, Julia [1 ]
Moscoso-Luduena, Cathleen [1 ]
Arya, Arash [1 ]
Shamloo, Alireza Sepehri [1 ,3 ]
Hindricks, Gerhard [1 ]
机构
[1] Univ Leipzig, Dept Electrophysiol, Heart Ctr Leipzig, Naumburger Str 76, D-04443 Weissenfels, Germany
[2] Asklepios Clin Weissenfels, Dept Cardiol, Weissenfels, Germany
[3] Leipzig Heart Inst, Leipzig, Germany
来源
EUROPACE | 2022年 / 24卷 / 10期
关键词
Pre-procedural fasting; Implantable cardiac defibrillator; Pacemaker; Aspiration; Patient-reported outcome measures; PULMONARY ASPIRATION; PATIENT COMFORT;
D O I
10.1093/europace/euac081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Data on safety and efficacy of a non-fasting strategy in minimal invasive cardiac procedures are lacking. We assessed a non-fasting strategy compared with a fasting strategy regarding patient's well-being and safety in elective cardiac implantable electronic device (CIED) procedures. Methods and results In this randomized, single-blinded clinical trial, 201 patients (non-fasting = 100, fasting = 101) with a mean age of 72.0 +/- 11.6 years (66.7% male) were assigned to a non-fasting strategy (solids/fluids allowed up to 1 h) or a fasting strategy (at least 6 h no solids and 2 h no fluids) before the procedure and analysed on an intention-to-treat basis. The co-primary outcomes were patients' well-being scores (based on numeric rating scale, 0-10) and incidence of intra-procedural food-related adverse events, including vomiting, perioperative pulmonary aspiration, and emergency intubation. Renal, haematological, and metabolic blood parameters and 30-day follow-up data were gathered. The summed pre-procedural patients' well-being score was significantly lower in the non-fasting group [non-fasting: 13.1 +/- 9.6 vs. fasting: 16.5 +/- 11.4, 95% confidence interval (CI) of mean difference (MD) -6.35 to -0.46, P = 0.029], which was mainly driven by significantly lower scores for hunger and tiredness in the non-fasting group (non-fasting vs. fasting; hunger: 0.9 +/- 1.9 vs. 3.1 +/- 3.2, 95% CI of MD -2.86 to -1.42, P < 0.001; tiredness: 1.6 +/- 2.3 vs. 2.6 +/- 2.7, 95% CI of MD -1.68 to -0.29, P = 0.023). No intra-procedural food-related adverse events were observed. Relevant blood parameters and 30-day follow-up did not show significant differences. Conclusion These results showed that a non-fasting strategy is beneficial to a fasting one regarding patient's well-being and comparable in terms of safety for CIED procedures (NCT04389697).
引用
收藏
页码:1617 / 1626
页数:10
相关论文
共 50 条
  • [41] First Case of Trichoderma longibrachiatum CIED (Cardiac Implantable Electronic Device)-Associated Endocarditis in a Non-immunocompromised Host: Biofilm Removal and Diagnostic Problems in the Light of the Current Literature
    Tascini, Carlo
    Cardinali, Gianluigi
    Barletta, Valentina
    Di Paolo, Antonello
    Leonildi, Alessandro
    Zucchelli, Giulio
    Corte, Laura
    Colabella, Claudia
    Roscini, Luca
    Consorte, Augusta
    Pasticci, Maria Bruna
    Menichetti, Francesco
    Bongiorni, Maria Grazia
    MYCOPATHOLOGIA, 2016, 181 (3-4) : 297 - 303
  • [42] Comparative study of electronic vs. paper VAS ratings: a randomized, crossover trial using healthy volunteers
    Jamison, RN
    Gracely, RH
    Raymond, SA
    Levine, JG
    Marino, B
    Herrmann, TJ
    Daly, M
    Fram, D
    Katz, NP
    PAIN, 2002, 99 (1-2) : 341 - 347
  • [43] The clinical use of remote parameter testing during cardiac implantable electronic devices implantation procedures: a single center, randomized, open-label, non-inferiority trial
    Xiong, Shiqiang
    Qin, Shujuan
    Tong, Lin
    Long, Yu
    Luo, Yan
    Feng, Qiao
    Peng, Xiufen
    Jiang, Maoling
    Xiong, Feng
    Li, Jin
    Zhang, Yangchun
    Zhang, Zhen
    Liu, Hanxiong
    Cai, Lin
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [44] Low-temperature electrocautery reduces adverse effects from secondary cardiac implantable electronic device procedures: Insights from the WRAP-IT trial
    Mittal, Suneet
    Wilkoff, Bruce L.
    Poole, Jeanne E.
    Kennergren, Charles
    Wright, David J.
    Berman, Brett J.
    Riggio, David
    Sholevar, Darius P.
    Martinez-Arraras, Joaquin
    Moubarak, Jean B.
    Schaller, Robert D.
    Love, John C.
    Pickett, Robert A.
    Philippon, Francois
    Eldadah, Zayd
    Lande, Jeffrey D.
    Lexcen, Daniel R.
    Holbrook, Reece
    Tarakji, Khaldoun G.
    HEART RHYTHM, 2021, 18 (07) : 1142 - 1150
  • [45] A randomized controlled trial to study the efficacy of 1% vs. 2% lignocaine in topical airway anesthesia in routine bronchoscopy procedures
    Prasad, Danny
    James, Prince
    Gupta, Richa
    EGYPTIAN JOURNAL OF BRONCHOLOGY, 2025, 19 (01)
  • [46] Comparing Efficacy and Safety of Empirical vs. Guided Therapy for Non-cardiac Chest Pain: A Pragmatic Randomized Trial
    Kadir, Noor Purdah Abdul
    Ma, Zheng Feei
    Hafidz, Muhammad Ilham Abdul
    Annamalai, Chandramouli
    Jayaraman, Thevaraajan
    Hamid, Nurhazwani
    Norhasliza, Siti
    Abd Aziz, Azliani
    Yusof, Zurkurnai
    Lee, Hady
    Lee, Yeong Yeh
    FRONTIERS IN MEDICINE, 2021, 8
  • [47] Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
    Han, Seungbong
    Park, Gyung-Min
    Kim, Yong-Giun
    Hwang, Ki Won
    Kwon, Chang Hee
    Roh, Jae-Hyung
    Park, Sangwoo
    Won, Ki-Bum
    Ann, Soe Hee
    Kim, Shin-Jae
    Lee, Sang-Gon
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [48] Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
    Seungbong Han
    Gyung-Min Park
    Yong-Giun Kim
    Ki Won Hwang
    Chang Hee Kwon
    Jae-Hyung Roh
    Sangwoo Park
    Ki-Bum Won
    Soe Hee Ann
    Shin-Jae Kim
    Sang-Gon Lee
    Scientific Reports, 11
  • [49] Visualizable vs. standard, non-visualizable steerable sheath for pulmonary vein isolation procedures: Randomized, single-centre trial
    Janosi, Kristof
    Debreceni, Dorottya
    Janosa, Benedek
    Bocz, Botond
    Simor, Tamas
    Kupo, Peter
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [50] Assessment of the efficacy of phentolamine to prevent radial artery spasm during cardiac catheterization procedures:: A randomized study comparing phentolamine vs. verapamil
    Ruiz-Salmerón, RJ
    Mora, R
    Masotti, M
    Betriu, A
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (02) : 192 - 198