IMRT delivery verification using a spiral phantom

被引:29
作者
Richardson, SL [1 ]
Tomé, WA
Orton, NP
McNutt, TR
Paliwal, BR
机构
[1] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
[2] Univ Wisconsin, Sch Med, Dept Human Oncol, Madison, WI 53792 USA
[3] Univ Wisconsin, Sch Med, Dept Med Phys, Madison, WI 53792 USA
[4] Philips Radiat Oncol Syst, Madison, WI USA
关键词
quality assurence; IMRT; QA phantoms;
D O I
10.1118/1.1603965
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper we report on the testing and verification of a system for IMRT delivery quality assurance that uses a cylindrical solid water phantom with a spiral trajectory for radiographic film placement. This spiral film technique provides more complete dosimetric verification of the entire IMRT treatment than perpendicular film methods, since it samples a three-dimensional dose subspace rather than using measurements at only one or two depths. As an example, the complete analysis of the predicted and measured spiral films is described for an intracranial IMRT treatment case. The results of this analysis are compared to those of a single field perpendicular film technique that is typically used for IMRT QA. The comparison demonstrates that both methods result in a dosimetric error within a clinical tolerance of 5%, however the spiral phantom QA technique provides a more complete dosimetric verification while being less time consuming. To independently verify the dosimetry obtained with the spiral film, the same IMRT treatment was delivered to a similar phantom in which LiF thermoluminescent dosimeters were arranged along the spiral trajectory. The maximum difference between the predicted and measured TLD data for the 1.8 Gy fraction was 0.06 Gy for a TLD located in a high dose gradient region. This further validates the ability of the spiral phantom QA process to accurately verify delivery of an IMRT plan. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2553 / 2558
页数:6
相关论文
共 18 条
[1]   Relative profile and dose verification of intensity-modulated radiation therapy [J].
Chang, JW ;
Mageras, GS ;
Chui, CS ;
Ling, CC ;
Lutz, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01) :231-240
[2]   Investigation of the use of MOSFET for clinical IMRT dosimetric verification [J].
Chuang, CF ;
Verhey, LJ ;
Xia, P .
MEDICAL PHYSICS, 2002, 29 (06) :1109-1115
[3]   Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation [J].
Ju, SG ;
Ahn, YC ;
Huh, SJ ;
Yeo, IJ .
MEDICAL PHYSICS, 2002, 29 (03) :351-355
[4]  
KASPER PL, 1999, MED PHYS, V36, P2373
[5]   Intensity modulated irradiation of a thorax phantom:: comparisons between measurements, Monte Carlo calculations and pencil beam calculations [J].
Laub, WU ;
Bakai, A ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06) :1695-1706
[6]   Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy [J].
Low, DA ;
Dempsey, JF ;
Venkatesan, R ;
Mutic, S ;
Markman, J ;
Haacke, EM ;
Purdy, JA .
MEDICAL PHYSICS, 1999, 26 (08) :1542-1551
[7]   Image localization for frameless stereotactic radiotherapy [J].
Meeks, SL ;
Bova, FJ ;
Wagner, TH ;
Buatti, JM ;
Friedman, WA ;
Foote, KD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (05) :1291-1299
[8]   A modified polymer gel for radiotherapy dosimetry: assessment by MRI and MRS [J].
Murphy, PS ;
Cosgrove, VP ;
Leach, MO ;
Webb, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3213-3223
[9]   Intensity-modulated radiotherapy by means of static tomotherapy: A planning and verification study [J].
Oldham, M ;
Webb, S .
MEDICAL PHYSICS, 1997, 24 (06) :827-836
[10]   A spiral phantom for IMRT and tomotherapy treatment delivery verification [J].
Paliwal, B ;
Tomé, W ;
Richardson, S ;
Mackie, TR .
MEDICAL PHYSICS, 2000, 27 (11) :2503-2507