Experimental characterization of moisture transport in brick masonry with natural hydraulic lime mortar

被引:15
作者
Ramirez, R. [1 ]
Ghiassi, B. [2 ]
Pineda, P. [3 ]
Lourenco, P. B. [1 ]
机构
[1] Univ Minho, Inst Sustainabil & Innovat Struct Engn ISISE, Dept Civil Engn, Campus Azurem S-N, P-4800085 Guimaraes, Portugal
[2] Univ Nottingham, Fac Engn, Ctr Struct Engn Design & Informat CSEI, Univ Pk, Nottingham NG7 2RD, England
[3] Univ Seville, Sch Architecture, Dept Bldg Struct & Geotech Engn, Avda Reina Mercedes 2, Seville 41012, Spain
关键词
Masonry; Moisture transport; Hygric characterization; Porous building material; Multi-layered material; Brick-mortar interface; POROUS BUILDING-MATERIALS; HYGRIC PROPERTIES; WATER-MOVEMENT; CONDUCTIVITY; TEMPERATURE; ABSORPTION; INSULATION; CONCRETE; MODEL;
D O I
10.1016/j.buildenv.2021.108256
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This article presents an experimental study on the hygric performance of brick masonry with a special focus on the hydraulic characterization of the brick-mortar interface. The hygric behavior was studied at the level of the constituent materials as well as at the composite scale. An extruded fired-clay brick and two types of mortar -Portland cement mortar and natural hydraulic lime mortar- were chosen as target materials. The hygric properties were determined following prescribed experimental procedures. The experimental program included vacuum saturation tests, static gravimetric tests for adsorption/desorption isotherms, dry/wet cup tests, capillary absorption tests, and isothermal one-dimensional drying. The results allowed for a comprehensive identification of the main hygric features of the target materials. Fired-clay brick and lime mortar revealed low hygroscopicity and a strong capillary-active behavior with negligible hysteresis, whereas cement mortar showed activity in both hygroscopic and capillary ranges with a distinct moisture storage hysteresis. Different curing conditions led to dissimilar properties between the lime mortar prepared in molds and the same mortar cured in masonry bed joints. Water absorption in fired-clay bricks showed a marked anisotropic behavior, likely derived from the extrusion process. The existence of an imperfect hydraulic contact at the brick-mortar interface was demonstrated for water absorption. Conversely, the interfacial effect on drying kinetics was not evident.
引用
收藏
页数:15
相关论文
共 62 条
[1]  
[Anonymous], 1980, Materiaux et Constructions, V13, P176
[2]  
[Anonymous], 2013, Conservation of Cultural Heritage. Determination of Drying Properties
[3]  
[Anonymous], 2011, Cement-Part 1: Composition, Specifications and Conformity Criteria for Common Cements
[4]  
[Anonymous], 1995, ASTM E 96, Vi, P1, DOI DOI 10.1520/E0096
[5]  
[Anonymous], 2009, 158032009 EN
[6]  
Azenha M., 2009, NUMERICAL SIMULATION
[7]  
Brocken H. J. P., 1998, THESIS TECHNISCHE U
[8]  
Brooks JJ, 2015, CONCRETE AND MASONRY MOVEMENTS, P223, DOI 10.1016/B978-0-12-801525-4.00008-X
[9]   Adsorption of gases in multimolecular layers [J].
Brunauer, S ;
Emmett, PH ;
Teller, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1938, 60 :309-319
[10]  
BS EN ISO, 2000, 125702000 BS EN ISO