摘要
Methods To investigate the safety and clinical significance of the method described in this study, we focused on 16 peritoneal dialysis patients with peritoneal dialysis (PD) catheter malposition and blockage in whom nonsurgical reposition was ineffective, who received a local incision about 5 cm below hypogastrium PD catheter insertions under local anesthesia. Tissues were separated layer by layer, 1-cm incisions were performed on the peritoneum vertically and conventionally, and then the PD catheters were pulled. Adherent mesentery was separated and the PD catheters were freed and removed sufficiently. PD catheters were introduced into the Dow cavity using large introducing forceps, were loop-ligated and fixed using 3# silk thread, and then the ligation line was sutured to the peritoneum. The tissues were managed layer by layer and the skin was sutured. All patients were followed up for half a year. Results Sixteen cases of refractory PD catheter malposition and blockage were managed successfully, with an operative incision of 3 cm and an operation time of 40 +/- 13 minutes. The localized anesthesia was well tolerated, and there were five cases in which lidocaine at 5 mg was added during the operation; postoperative pain was slight and only three patients used analgesics at night. All patients were treated with coagulation hemostasis, and there was no transfusion. No malposition, leakage or blockage was found at follow-up at more than six months. Conclusion It is safe, simple, inexpensive and associated with fewer complications to correct refractory PD catheter malposition and blockage by loop ligature and fixation through a minilaparotomy of inserted hypogastrium PD catheters promptly.
引用
收藏
页码:1525 / 1528
页数:4
相关论文
共 50 条
  • [1] PREPERITONEAL TUNNELING - A NOVEL TECHNIQUE IN PERITONEAL DIALYSIS CATHETER INSERTION
    Modaghegh, Mohammad-Hadi Saeed
    Kazemzadeh, Gholamhossein
    Rajabnejad, Yaser
    Nazemian, Fatemeh
    PERITONEAL DIALYSIS INTERNATIONAL, 2014, 34 (04): : 443 - 446
  • [2] A modified open surgical revision technique for malfunctioning peritoneal dialysis catheter
    Xiang, Shilong
    Zhang, Xiaohui
    Wang, Yaomin
    Liu, Guangjun
    Xie, Xishao
    Han, Fei
    Chen, Jianghua
    RENAL FAILURE, 2024, 46 (02)
  • [3] Laparoscopic preperitoneal tunneling technique using a novel device for peritoneal dialysis catheter placement
    Lin, Bo
    Liu, Yueming
    Shen, Xiaogang
    Chen, Wangfang
    Jiang, Xinxin
    He, Qiang
    CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2020, 24 (11) : 1044 - 1049
  • [4] Peritoneal dialysis catheter insertion and maintenance
    Wynn, James J.
    SEMINARS IN VASCULAR SURGERY, 2024, 37 (04) : 375 - 386
  • [5] Peritoneal Dialysis Catheter Revision and Replacement by Nephrologist for Peritoneal Dialysis Catheter Malfunction
    Ma, Terry King-Wing
    Chow, Kai Ming
    Kwan, Bonnie Ching-Ha
    Ng, Jack Kit-Chung
    Choy, Agnes Shin-Man
    Kwong, Vickie Wai-Ki
    Pang, Wing-Fai
    Leung, Chi Bon
    Li, Philip Kam-To
    Szeto, Cheuk Chun
    NEPHRON, 2018, 138 (03) : 214 - 219
  • [6] A Technique to Address Peritoneal Dialysis Catheter Malfunction
    Stucky, Chee-Chee H.
    Mason, Mark C.
    Madura, James A., II
    Harold, Kristi L.
    JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2010, 14 (04) : 608 - 610
  • [7] Peritoneal dialysis catheter placement technique and complications
    Peppelenbosch, Arnoud
    van Kuijk, Willy H. M.
    Bouvy, Nicole D.
    van der Sande, Frank M.
    Tordoir, Jan H. M.
    CLINICAL KIDNEY JOURNAL, 2008, 1 : IV23 - IV28
  • [8] Clinical technique: Peritoneal dialysis and percutaneous peritoneal dialysis catheter placement in small mammals
    Wojick, Kimberlee
    Berube, Danielle
    Barr, James, III
    JOURNAL OF EXOTIC PET MEDICINE, 2008, 17 (03) : 181 - 188
  • [9] A MODIFIED OPEN SURGERY TECHNIQUE FOR PERITONEAL DIALYSIS CATHETER PLACEMENT DECREASES CATHETER MALFUNCTION
    Jiang, Chunming
    Xu, Linfeng
    Chen, Yun
    Yan, Xiang
    Sun, Cheng
    Zhang, Miao
    PERITONEAL DIALYSIS INTERNATIONAL, 2014, 34 (04): : 358 - 367
  • [10] MODIFIED SIMPLE PERITONEAL WALL ANCHOR TECHNIQUE (PWAT) IN PERITONEAL DIALYSIS
    Oka, Hideaki
    Yamada, Shunsuke
    Kamimura, Taro
    Hara, Masatoshi
    Hirashima, Yutaro
    Matsueda, Shumei
    Shukuri, Tomoya
    Aihara, Seishi
    Koresawa, Mai
    Eriguchi, Masahiro
    Harada, Atsumi
    Tsuruya, Kazuhiko
    Kitazono, Takanari
    PERITONEAL DIALYSIS INTERNATIONAL, 2017, 37 (01): : 103 - 108