Carotid artery distensibility - A reliability study

被引:100
作者
Godia, Elisa Cuadrado
Madhok, Rishi
Pittman, John
Trocio, Samuel
Ramas, Romel
Cabral, Digna
Sacco, Ralph L.
Rundek, Tatjana
机构
[1] Columbia Univ, Dept Epidemiol, New York, NY USA
[2] Columbia Univ, Gertrude H Sergievsky Ctr, New York, NY 10027 USA
[3] Columbia Univ, Dept Neurol, Div Stroke, New York, NY 10027 USA
关键词
atherosclerosis; carotid distensibility; carotid sonography; reliability;
D O I
10.7863/jum.2007.26.9.1157
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. Carotid distensibility (CD) is a measure of carotid artery elasticity that has been introduced as a risk factor for cardiovascular disease. information regarding reproducibility of sonographic CD measures is limited. The objective of this study was to evaluate the inter-reader reliability of sonographic measurements of common carotid artery (CCA) diameters and derived metrics of CD. Methods. Two independent readers (R1 and R2) measured the systolic diameter (SD) and diastolic diameter (DD) for the right CCA from the B/M-mocle sonographic registrations among 118 subjects. The derived CD metrics (strain, elastic modulus [E], stiffness [P], and CID) were calculated. The inter-reader type 3 intraclass correlation coefficients (ICC3,1) for carotid diameters were calculated. Results. The mean SDs standard deviation were 7.15 +/- 1.43 mm for R1 and 7.24 +/- 1.43 mm for R2. The mean DDs were 6.71 +/- 1.36 mm for R1 and 6.68 +/- 1.41 mm for R2. The mean differences of SD and DD between R1 and R2 were 0.08 +/- 0.40 mm (paired t test, P =.04) and 0.03 +/- 0.43 mm (paired t test, P =.46), respectively Inter-reader type 3 intraclass correlation coefficients were 0.96 for SD and 0.95 for DD. We observed a significant association of demographics with carotid diameters but not with derived CD metrics or risk factors. Conclusions. Our results suggest good reproducibility of CCA diameters measured with B/Mmode sonography. However, very small changes in linear measurements of carotid diameters can have big effects on estimates of arterial mechanical properties such as strain and Young's modulus. The standard boundary identification methods may not be precise and reproducible enough for use in a clinical setting.
引用
收藏
页码:1157 / 1165
页数:9
相关论文
共 38 条
[1]   Suppressed anger is associated with increased carotid arterial stiffness in older adults [J].
Anderson, David E. ;
Metter, E. Jeffrey ;
Hougaku, Hidetaka ;
Najjar, Samer S. .
AMERICAN JOURNAL OF HYPERTENSION, 2006, 19 (11) :1129-1134
[2]   Variability in ultrasonic measurements of arterial stiffness in the atherosclerosis risk in communities study [J].
Arnett, DK ;
Chambless, LE ;
Evans, GW ;
Riley, W .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (02) :175-180
[3]   Multi-ethnic study of atherosclerosis: Objectives and design [J].
Bild, DE ;
Bluemke, DA ;
Burke, GL ;
Detrano, R ;
Roux, AVD ;
Folsom, AR ;
Greenland, P ;
Jacobs, DR ;
Kronmal, R ;
Liu, K ;
Nelson, JC ;
O'Leary, D ;
Saad, MF ;
Shea, S ;
Szklo, M ;
Tracy, RP .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2002, 156 (09) :871-881
[4]   Carotid arterial stiffness as a predictor of cardiovascular and all-cause mortality in end-stage renal disease [J].
Blacher, J ;
Pannier, B ;
Guerin, AP ;
Marchais, SJ ;
Safar, ME ;
London, GM .
HYPERTENSION, 1998, 32 (03) :570-574
[5]   COMMON CAROTID-ARTERY STIFFNESS AND PATTERNS OF LEFT-VENTRICULAR HYPERTROPHY IN HYPERTENSIVE PATIENTS [J].
BOUTOUYRIE, P ;
LAURENT, S ;
GIRERD, X ;
BENETOS, A ;
LACOLLEY, P ;
ABERGEL, E ;
SAFAR, M .
HYPERTENSION, 1995, 25 (04) :651-659
[6]  
British Standards Institution, 1975, PREC TEST METH 1 G 1, pBS597
[7]   Carotid stiffness indicates risk of ischemic stroke and TIA in patients with internal carotid artery stenosis - The SMART study [J].
Dijk, JM ;
van der Graaf, Y ;
Grobbee, DE ;
Bots, ML .
STROKE, 2004, 35 (10) :2258-2262
[8]   Arterial stiffness is greater in African Americans than in whites - Evidence from the Forsyth County, North Carolina, ARIC Cohort [J].
Din-Dzietham, R ;
Couper, D ;
Evans, G ;
Arnett, DK ;
Jones, DW .
AMERICAN JOURNAL OF HYPERTENSION, 2004, 17 (04) :304-313
[9]   Elevated white blood cell count and carotid plaque thickness - The Northern Manhattan Stroke Study [J].
Elkind, MS ;
Cheng, JF ;
Boden-Albala, B ;
Paik, MC ;
Sacco, RL .
STROKE, 2001, 32 (04) :842-849
[10]   EFFECTS OF MEASUREMENT ERRORS ON SOME MULTIVARIATE PROCEDURES [J].
FLEISS, JL ;
SHROUT, PE .
AMERICAN JOURNAL OF PUBLIC HEALTH, 1977, 67 (12) :1188-1191