Time integrated phosphor behavior in gated image intensifier tubes

被引:0
|
作者
Höss, P [1 ]
Fleder, K [1 ]
机构
[1] Stanford Comp Opt Inc, Berkeley, CA 94708 USA
来源
关键词
image intensifier; phosphor decay; flow analysis; P20; phosphor; P43;
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
New flow analysis applications of MCP image intensifier tubes require faster image repetition rates. When coupled to CCD readout chips their time-integrated behavior determines the overall system's response concerning the intensity of unwanted "ghost" images. Previously published experimental data as well as manufacturer's literature provide only time resolved response information. New data for the widely used high-efficiency, slow-decay P20 and P43 phosphors are determined as functions of both exposure (excitation) time and interframe time. Previously reported dependency of decay time being determined solely by the preceding exposure time is not supported by new data. Data herein show an increase of decay time by more than a factor of 100, especially for short excitation times. This is caused by intensity integration on the CCD chip. The P20 shows a very long non-exponential decay. Though being faster during the initial 200 to 500 mus, the P20's decay extends over a substantially longer time as compared to the P43 phosphor. This is in clear contradiction to earlier results, which could lead to the expectation of the P20 being more than an order of magnitude faster than P43 for very short exposure times.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [41] RECENT DEVELOPMENTS AND APPLICATIONS ON ELECTRON-BOMBARDED CCDS IN IMAGE INTENSIFIER TUBES
    RICHARD, JC
    VITTOT, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3): : 368 - 374
  • [42] Surface analysis of microchannel plate in generation 2 image intensifier tubes by XPS
    Che, Jing
    Yang, Weiyi
    Lix, Xiaofeng
    Chang, Benkang
    Nanjing Li Gong Daxue Xuebao/Journal of Nanjing University of Science and Technology, 1998, 22 (02): : 149 - 152
  • [43] TESTS OF 4 SINGLE-STAGE IMAGE INTENSIFIER TUBES FOR SOLAR SPECTROSCOPY
    BRANDT, PN
    WIESMEIER, A
    SOLAR PHYSICS, 1974, 38 (02) : 517 - 521
  • [44] Auto-gated Power Supply for Low-light Level Image Intensifier
    Yang Ye
    Zhi Qiang
    Yan Bo
    Yao Ze
    Li Jun-guo
    Wang Yu
    Ni Xiao-bing
    Fu Ling-yun
    Deng Guang-xu
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: LOW-LIGHT-LEVEL TECHNOLOGY AND APPLICATIONS, 2013, 8912
  • [45] Quantitative diffuse optical tomography for small animals using an ultrafast gated image intensifier
    Patwardhan, Sachin V.
    Culver, Joseph P.
    2008, SPIE (13)
  • [46] NANOGATE - A NANOSECOND GATED IMAGE INTENSIFIER WITH HIGH-GAIN AND HIGH-RESOLUTION
    PFEIFFER, W
    WITTMER, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 429 - 432
  • [47] Quantitative diffuse optical tomography for small animals using an ultrafast gated image intensifier
    Patwardhan, Sachin V.
    Culver, Joseph P.
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (01)
  • [49] EVALUATION OF HIGH QUALITY PHOSPHOR SCREENS FOR IMAGE TUBES.
    Varma, B.P.
    Ghosh, C.
    Indian Journal of Pure and Applied Physics, 1974, 12 (10): : 670 - 674
  • [50] EVALUATION OF HIGH-QUALITY PHOSPHOR SCREENS FOR IMAGE TUBES
    VARMA, BP
    GHOSH, C
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1974, 12 (10) : 670 - 674