Design and validation of portable SPME devices for rapid field air sampling and diffusion based calibration

被引:101
作者
Augusto, F [1 ]
Koziel, J [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac000629k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of SPME fibers coated with porous polymer solid phases for quantitative purposes is limited due to effects such as interanalyte displacement and competitive adsorption. For air analysis, these problems can be averted by employing short exposure times to air samples flowing around the fiber. In these conditions, a simple mathematical model allows quantification without the need of calibration curves. This work describes two portable dynamic air sampling (PDAS) devices designed for application of this approach to nonequilibrium SPME sampling and determination of airborne volatile organic compounds (VOCs). The use of a PDAS device resulted in greater adsorbed VOC mass compared to the conventional SPME extraction in static air for qualitative screening of live plant aromas and contaminants in indoor air. For all studied air samples, an increase in the number of detected compounds and sensitivity was also observed. Quantification of aromatic VOCs in indoor air was also carried out using this approach and the PDAS/SPME device. Measured VOC concentrations were in lour parts-per-billion by volume range using only 30-s SPME fiber exposure and were comparable to those obtained with a standard NIOSH method 1501. The use of PDAS/SPME devices reduced the total air sampling and analysis time by several orders of magnitude compared to the NIOSH 1501 method.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 24 条
[1]   Screening of Brazilian fruit aromas using solid-phase microextraction-gas chromatography-mass spectrometry [J].
Augusto, F ;
Valente, ALP ;
Tada, ED ;
Rivellino, SR .
JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (01) :117-127
[2]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[3]   Anthropogenic volatile organic compounds in ambient air and natural waters: a review on recent developments of analytical methodology, performance and interpretation of field measurements [J].
Dewulf, J ;
Van Langenhove, H .
JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) :163-177
[4]   Design of an automated analysis system for the determination of organic compounds in continuous air stream using solid-phase microextraction [J].
Eisert, R ;
Pawliszyn, J ;
Barinshteyn, G ;
Chambers, D .
ANALYTICAL COMMUNICATIONS, 1998, 35 (06) :187-189
[5]   A NEW METHOD FOR PREDICTION OF BINARY GAS-PHASE DIFFUSION COEFFECIENTS [J].
FULLER, EN ;
SCHETTLE, PD ;
GIDDINGS, JC .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1966, 58 (05) :19-+
[6]   Theory of analyte extraction by selected porous polymer SPME fibres [J].
Górecki, T ;
Yu, XM ;
Pawliszyn, J .
ANALYST, 1999, 124 (05) :643-649
[7]  
GORECKI T, 1999, APPL SOLID PHASE MIC, P92
[8]   Solid-phase microextraction for the analysis of human breath [J].
Grote, C ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :587-596
[9]   WATER-ADSORPTION CAPACITY OF THE SOLID ADSORBENTS TENAX-TA, TENAX-GR, CARBOTRAP, CARBOTRAP-C, CARBOSIEVE-SIII, AND CARBOXEN-569 AND WATER MANAGEMENT-TECHNIQUES FOR THE ATMOSPHERIC SAMPLING OF VOLATILE ORGANIC TRACE GASES [J].
HELMIG, D ;
VIERLING, L .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4380-4386
[10]   Air sampling with porous solid-phase microextraction fibers [J].
Koziel, J ;
Jia, MY ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5178-5186