Hemodynamic Characteristics and Clinical Outcome for Intracranial Aneurysms Treated with the Derivo Embolization Device, a Novel Second-Generation Flow Diverter

被引:8
|
作者
Fujimura, Soichiro [1 ,3 ]
Brehm, Alex [5 ]
Takao, Hiroyuki [2 ,3 ,4 ]
Uchiyama, Yuya [2 ,3 ]
Karagiozov, Kostadin [4 ]
Fukudome, Koji [1 ]
Yamamoto, Makoto [1 ]
Murayama, Yuichi [4 ]
Psychogios, Marios-Nikos [5 ]
机构
[1] Tokyo Univ Sci, Dept Mech Engn, Katsushika Ku, Tokyo, Japan
[2] Tokyo Univ Sci, Grad Sch Mech Engn, Katsushika Ku, Tokyo, Japan
[3] Jikei Univ, Dept Innovat Med Informat Technol, Sch Med, Minato Ku, Tokyo, Japan
[4] Jikei Univ, Dept Neurosurg, Sch Med, Minato Ku, Tokyo, Japan
[5] Univ Hosp Basel, Dept Neuroradiol, Clin Radiol & Nucl Med, Basel, Switzerland
关键词
Aneurysm; CFD; Devivo embolization device; Flow diverter stent; DIVERSION; PIPELINE;
D O I
10.1016/j.wneu.2021.12.033
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: We investigated the relationship between hemodynamic characteristics and clinical outcomes for aneurysms treated by the Derivo embolization device, a novel second-generation flow-diverter stent, using computational fluid dynamics (CFD). METHODS: Data were retrospectively obtained from 2 centers between 2017 and 2019. During the period, 23 patients were treated for 23 aneurysms with the Derivo embolization device. In 17 patients we were able to conduct CFD analysis as 6 were excluded due to precoiling, unsuitable arterial geometry, and complex geometric form. Aneurysm occlusion was rated with the O'Kelly-Marotta grading scale on digital subtraction angiography 6 months after stent placement in all patients. Hemodynamic and morphologic parameters were statistically compared between 2 groups: with full occlusion and with a remnant. RESULTS: Full occlusion was observed in 17 of 23 (73.9%) patients. In the group suitable for CFD analysis, we observed 13 fully occluded aneurysms and 4 with any remnant (specifically 1 O'Kelly-Marotta C, 1 B, and 2 A). The energy loss per volume, which indicates the energy loss through the aneurysm, was significantly larger in prestenting and post stenting (P < 0.05) in the complete occlusion cases. In addition, the inflow concentration index and inflow area ratio of the remnant cases were significantly larger and lower, respectively (P < 0.05). CONCLUSIONS: Our CFD results indicate that the energy loss involved with the blood flow passing through an aneurysm and concentrated inflow into an aneurysm were the most important factors to determine whether an aneurysm will become a complete occlusion or remnant case.
引用
收藏
页码:E252 / E259
页数:8
相关论文
共 16 条
  • [1] The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model
    Ley, D.
    Muehl-Benninghaus, R.
    Yilmaz, U.
    Koerner, H.
    Cattaneo, G. F. M.
    Mailaender, W.
    Kim, Y-J.
    Scheller, B.
    Reith, W.
    Simgen, A.
    CLINICAL NEURORADIOLOGY, 2017, 27 (03) : 335 - 343
  • [2] First clinical experience with the Derivo 2heal embolization device for the treatment of intracranial aneurysms
    Goertz, Lukas
    Zopfs, David
    Schoenfeld, Michael
    Zaeske, Charlotte
    Pennig, Lenhard
    Brinker, Gerrit
    Schlamann, Marc
    Kabbasch, Christoph
    INTERVENTIONAL NEURORADIOLOGY, 2023,
  • [3] Single-center experience with the new-generation Derivo embolization device for ruptured and unruptured intracranial aneurysms
    Kaschner, Marius G.
    Petridis, Athanasios
    Turowski, Bernd
    JOURNAL OF NEUROSURGICAL SCIENCES, 2020, 64 (04) : 353 - 363
  • [4] A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment
    Monteiro, Andre
    Burke, Samantha M.
    Baig, Ammad A.
    Khan, Slah
    Cappuzzo, Justin M.
    Waqas, Muhammad
    Dietrich, Joseph E.
    Levy, Elad, I
    Siddiqui, Adnan H.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2022, 14 (11) : 1125 - 1129
  • [5] Endovascular treatment of complex intracranial aneurysms by pipeline flow-diverter embolization device: a single-center experience
    Keskin, Fatih
    Erdi, Fatih
    Kaya, Bulent
    Poyraz, Necdet
    Keskin, Suat
    Kalkan, Erdal
    Ozbek, Orhan
    Koc, Osman
    NEUROLOGICAL RESEARCH, 2015, 37 (04) : 359 - 365
  • [6] Improved Occlusion Rate of Intracranial Aneurysms Treated with the Derivo Embolization Device: One-Year Clinical and Angiographic Follow-Up in a Multicenter Study
    Goertz, Lukas
    Dorn, Franziska
    Kraus, Bastian
    Borggrefe, Jan
    Forbrig, Robert
    Schlamann, Marc
    Liebig, Thomas
    Turowski, Bernd
    Kabbasch, Christoph
    WORLD NEUROSURGERY, 2019, 126 : E1503 - E1509
  • [7] Usefulness of Silent MR Angiography for Intracranial Aneurysms Treated with a Flow-Diverter Device
    Oishi, H.
    Fujii, T.
    Suzuki, M.
    Takano, N.
    Teranishi, K.
    Yatomi, K.
    Kitamura, T.
    Yamamoto, M.
    Aoki, S.
    Arai, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : 808 - 814
  • [8] Periprocedural complications of second-generation flow diverter treatment using Pipeline Flex for unruptured intracranial aneurysms: a systematic review and meta-analysis
    Bhatia, Kartik Dev
    Kortman, Hans
    Orru, Emanuele
    Klostranec, Jesse M.
    Pereira, Vitor M.
    Krings, Timo
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (08) : 817 - 824
  • [9] Association between hemodynamic modifications and clinical outcome of intracranial aneurysms treated using flow diverters
    Paliwal, Nikhil
    Damiano, Robert J.
    Davies, Jason M.
    Siddiqui, Adnan H.
    Meng, Hui
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [10] Predictors of Clinical Outcome After Treatment of Intracranial Aneurysms with the Pipeline Embolization Device
    Griffin, Andrew
    Reese, Vanessa
    Huseyinoglu, Zeynep
    Niedzwiecki, Donna
    Yang, Lexie
    Cutler, Andrew
    Gonzalez, L. Fernando
    Zomorodi, Ali
    Smith, Tony
    Hauck, Erik F.
    WORLD NEUROSURGERY, 2019, 130 : E666 - E671